Inspections for the day of: Friday, March 20, 2020.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJames Ady
TitleELE-INSPECTOR
Phone #914-4683
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-04678 Rough-In Permanent Service3/20/20203/20/20203/20/2020 2:02:25 PMPFAIL
Garage code 4224. Floor heat inspection in master bath Phone #: ###-#### Inspection requested via web by Troy Ballard 110.3 Splice between cold and hot leads to be burried in thin set, sensor required to be 24in from wall and centered between parallel heating leads
ELE20-00953 Conference3/17/20203/20/20203/20/2020 2:00:16 PMPPASS
Please give 30 min notice for travel. Phone #: ###-#### Inspection requested via web by Andy Gabiou Discussed connection of a 30A generator recep and breaker interlock.
ELE19-04505 Electrical Rough-In3/20/20203/20/20203/20/2020 1:43:50 PMPPASS
Phone #: ###-#### Inspection requested via web by Jeremy Cloud TV recep area's excluded from inspection. Remaining area ok walls only ok to cover
ELE20-00453 Electrical Rough-In3/20/20203/20/20203/20/2020 1:08:56 PMPPASS
Addition and entrance to is at back of house Phone #: ###-#### Inspection requested via web by steve sellers M. bed, bath, closet and living rm ok to cover
ELE20-00319 Rough-In Permanent Service3/20/20203/20/20203/20/2020 12:40:42 PMPPASS
Phone #: ###-#### Inspection requested via web by Robert Schroder rough in ok p/s u/g n ok
ELE19-01667 Electrical Rough-In3/19/20203/20/20203/20/2020 11:02:59 AMAPASS
Phone #: ###-#### Inspection requested via web by mark mccullough rough in ok
ELE19-01667 Permanent Service3/20/20203/20/20203/20/2020 11:02:34 AMPPASS
Phone #: ###-#### Inspection requested via web by mark mccullough p/s u/g n ok
ELE19-04111 Final3/20/20203/20/20203/20/2020 10:18:30 AMAPASS
garage code 4224 Phone #: ###-#### Inspection requested via web by Troy Ballard final ok
ELE20-00768 Temporary Service3/19/20203/20/20203/20/2020 9:02:42 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE20-00769 Temporary Service3/19/20203/20/20203/20/2020 9:02:25 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
ELE19-01215 Electrical Rough-In3/18/20203/20/20203/20/2020 8:54:29 AMAPASS
Phone #: ###-#### Inspection requested via web by Dru Nakaya Receps and switches were checked for final. GFCI breaker needed for Garage door and GFCI protection needed on recep facing garage on bathroom wall. Rough in ok.
ELE19-04505 Electrical Rough-In3/18/20203/20/20203/20/2020 8:30:56 AMANR
Phone #: ###-#### Inspection requested via web by Jeremy Cloud not ready re call
ELE19-04678 Electrical Rough-In3/19/20203/20/20203/20/2020 5:58:02 AMACANC
Inspection for Master Bath floor heat Phone #: ###-#### >> Inspection requested via web by Troy Ballard Inspection cancelled from web by: Troy Ballard