ELE05-00818
| Rough-In Permanent Service | 3/17/2005 | 3/21/2005 | 3/21/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 3/17/2005 at 3:49:33 PM. Contact: ###-####. saw elect about 1 1/4' to dr and heater contr pulling staples for nm cable. ric ok, p/s u/g n ok 3/21/2005 9:14:22 AM
|
ELE05-00913
| Rough-In Permanent Service | 3/18/2005 | 3/21/2005 | 3/21/2005 12:00:00 AM | A | PASS |
|
|
###-#### darrell ric ok , p/s u/g n ok 3/21/2005 7:46:26 AM
|
ELE04-02859
| Final | 3/18/2005 | 3/21/2005 | 3/21/2005 12:00:00 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Gary Foreman called contr to change laundry recpt since sink adjacent to washer. ok to final 3/21/2005 8:14:36 AM
|
ELE05-00637
| Rough-In Permanent Service | 3/21/2005 | 3/21/2005 | 3/21/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 3/21/2005 at 6:50:14 AM. Contact: ###-####. p/s, existing meter bank, n, ok 3/21/2005 9:58:25 AM
|
ELE05-00816
| Rough-In Permanent Service | 3/17/2005 | 3/21/2005 | 3/21/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 3/17/2005 at 3:28:31 PM. Contact: ###-####. ric ok p/s u/g n ok 3/21/2005 9:27:06 AM
|
ELE05-00830
| Electrical Rough-In | 3/21/2005 | 3/21/2005 | 3/21/2005 12:00:00 AM | P | PASS |
|
|
phil; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corrections made, ric only ok. Need to look at service later. 3/21/2005 3:50:56 PM
|
ELE05-00028
| Final | 3/21/2005 | 3/21/2005 | 3/21/2005 12:00:00 AM | P | FAIL |
|
|
jack; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, left correction notice, 314.15(A) emt connectors and fittings shall be listed for wet locations, 408.4 panel schedule shall have details, 406.5 recepts shall have faceplate, 406.2 range recpt shall be provided,210.11(C)(2) laundry recpt shall work, 210.70(A)(2)(b) light shall work at garage, 300.5 shall uncover u/g to garage to verify depth of wiring. 3/21/2005 2:29:48 PM
|
ELE05-00656
| Electrical Rough-In | 3/21/2005 | 3/21/2005 | 3/21/2005 12:00:00 AM | P | FAIL |
|
|
chris; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles 300.4(D) nm cable shall be 1 1/4" from edge of framing member, North of fireplace, down low. 314.23(B)(1) boxes shall be securely fastened, North wall of garage, and North of garage door 3/21/2005 12:41:26 PM
|
ELE05-00817
| Rough-In Permanent Service | 3/17/2005 | 3/21/2005 | 3/17/2005 3:50:04 PM | A | CANC |
|
|
Scheduled by a contractor via Hello! on 3/17/2005 at 3:29:06 PM. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on Mar 17 2005 3:50PM.
|