Inspections for the day of: Monday, March 21, 2005.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-00818 Rough-In Permanent Service3/17/20053/21/20053/21/2005 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 3/17/2005 at 3:49:33 PM. Contact: ###-####. saw elect about 1 1/4' to dr and heater contr pulling staples for nm cable. ric ok, p/s u/g n ok 3/21/2005 9:14:22 AM
ELE05-00913 Rough-In Permanent Service3/18/20053/21/20053/21/2005 12:00:00 AMAPASS
###-#### darrell ric ok , p/s u/g n ok 3/21/2005 7:46:26 AM
ELE04-02859 Final3/18/20053/21/20053/21/2005 12:00:00 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Gary Foreman called contr to change laundry recpt since sink adjacent to washer. ok to final 3/21/2005 8:14:36 AM
ELE05-00637 Rough-In Permanent Service3/21/20053/21/20053/21/2005 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 3/21/2005 at 6:50:14 AM. Contact: ###-####. p/s, existing meter bank, n, ok 3/21/2005 9:58:25 AM
ELE05-00816 Rough-In Permanent Service3/17/20053/21/20053/21/2005 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 3/17/2005 at 3:28:31 PM. Contact: ###-####. ric ok p/s u/g n ok 3/21/2005 9:27:06 AM
ELE05-00830 Electrical Rough-In3/21/20053/21/20053/21/2005 12:00:00 AMPPASS
phil; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corrections made, ric only ok. Need to look at service later. 3/21/2005 3:50:56 PM
ELE05-00028 Final3/21/20053/21/20053/21/2005 12:00:00 AMPFAIL
jack; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, left correction notice, 314.15(A) emt connectors and fittings shall be listed for wet locations, 408.4 panel schedule shall have details, 406.5 recepts shall have faceplate, 406.2 range recpt shall be provided,210.11(C)(2) laundry recpt shall work, 210.70(A)(2)(b) light shall work at garage, 300.5 shall uncover u/g to garage to verify depth of wiring. 3/21/2005 2:29:48 PM
ELE05-00656 Electrical Rough-In3/21/20053/21/20053/21/2005 12:00:00 AMPFAIL
chris; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles 300.4(D) nm cable shall be 1 1/4" from edge of framing member, North of fireplace, down low. 314.23(B)(1) boxes shall be securely fastened, North wall of garage, and North of garage door 3/21/2005 12:41:26 PM
ELE05-00817 Rough-In Permanent Service3/17/20053/21/20053/17/2005 3:50:04 PMACANC
Scheduled by a contractor via Hello! on 3/17/2005 at 3:29:06 PM. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on Mar 17 2005 3:50PM.