Inspections for the day of: Tuesday, March 21, 2006.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03223 ELE-Aging Inspection3/21/20063/21/20063/22/2006 11:44:44 AM NR
contractor said that they are still working on the alarms.
ELE06-00862 Rough-In Permanent Service3/21/20063/21/20063/21/2006 4:36:21 PMPPART
need rough in on upstairs . thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH
no service this is just a R/I
upstairs R/I Ok
ELE05-01631 Electrical Rough-In3/21/20063/21/20063/21/2006 3:41:33 PMPPART
Scheduled by a contractor via Hello! on 3/21/2006 at 7:24:29 AM. Contact: ###-####.
bathrooms on 3 floors and site work on 10th st side
ELE06-00851 Electrical Rough-In3/21/20063/21/20063/21/2006 3:19:58 PMPFAIL
COVER INSPECTION PLEASE @ MONGOLIAN GRILL............THANKS; Phone #: ###-#### Internet Inspection Request from: Barry Kendall
protection of cable
ELE06-00706 Electrical Rough-In3/21/20063/21/20063/21/2006 2:30:38 PMPPART
###-#### - dave
walls ok
ELE05-03541 Final3/21/20063/21/20063/21/2006 1:48:39 PMPFAIL
Mike; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
210.52 Dwelling Unit Receptacle Outlets.
(A) General Provisions
(D) Bathrooms. In dwelling units, at least one wall receptacle outlet shall be installed in bathrooms within 900 mm (3 ft) of the outside edge of each basin

210.52(C) Countertops. In kitchens and dining rooms of dwelling units, receptacle outlets for counter spaces shall be installed in accordance with 210.52(C)(1) through (5).

110.3 Examination, Identification, Installation, and Use of Equipment.
(B) Installation and Use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

All counters, sinks and cabinets shall be installed for final inspection.
Boise City code 4-05-28 may be enforced through disconnection of power if this residence is occupied prior to passing a final inspection.
ELE05-01705 ELE-Aging Inspection3/21/20063/21/20063/21/2006 10:39:04 AM NR
called contractor and told him that we must have some action taken on this job in a timeley fashion or further action will be taken.
ELE05-02169 ELE-Aging Inspection3/21/20063/21/20063/21/2006 10:19:41 AM NR
Job seems to be at a standstill called contractor and got no response address also seems to be wrong. 512, 514, 516
ELE05-04074 Final3/20/20063/21/20063/21/2006 9:32:56 AMAFAIL
Michael; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
recep required for A/C and install outside light by door.
ELE06-00939 Conference3/20/20063/21/20063/21/2006 8:58:15 AMAPART
8:30 am
duplicate
ELE06-00939 Conference3/20/20063/21/20063/21/2006 8:57:11 AMAPART
###-#### Tracy -- conference with Jim Schmer and Pat Lass per Jim Schmer; 8:30 - 8:45 AM; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
talked about fire barier and romex in a raceway
ELE06-00929 Rough-In Permanent Service3/20/20063/21/20063/21/2006 6:44:26 AMPCANC
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson Inspection cancelled from web by: Therrin Robertson