ELE16-03138
| ELE-Aging Inspection | 3/21/2019 | 3/21/2019 | 3/22/2019 2:38:16 PM | | PASS |
|
|
final scheduled...see notes
|
ELE19-00976
| Conference | 3/20/2019 | 3/21/2019 | 3/21/2019 3:08:29 PM | P | PASS |
|
|
Would prefer after 1:15 PM. I will be in meetings prior to that. Phone #: ###-#### Inspection requested via web by Jason McKenzie... reviewed wiring of new family rm, storage rm, garage and music rm...homeowner competent in work and has done previous work on other permit
|
ELE19-00636
| Final | 3/20/2019 | 3/21/2019 | 3/21/2019 2:02:46 PM | P | PASS |
|
|
8014418543 is the phone number. Need Final inspection . Phone #: ###-#### Inspection requested via web by Coulton Main... labelling, disconnect, and OCPD ok
|
ELE18-00860
| Final | 3/20/2019 | 3/21/2019 | 3/21/2019 1:31:00 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Justin Hone... ok to final
|
ELE17-04336
| Final | 3/19/2019 | 3/21/2019 | 3/21/2019 1:12:24 PM | P | FAIL |
|
|
customer phone # ###-####, closing out old permits Phone #: ###-#### Inspection requested via web by Matthew White... 1) wiring of hot tub-680.40 2) all metal within 6ft of tub needs bonded 3) outlets GFCI protection 4) panel needs complete labelling 5) electrical work done without permit and inspection...car charger outlet...listing and labelling for circuit required
|
ELE19-00978
| Temporary Service | 3/21/2019 | 3/21/2019 | 3/21/2019 12:04:05 PM | P | PASS |
|
|
this is a temp overhead power pole Phone #: ###-#### Inspection requested via web by Paula Gratiot... t/s o/h new ok...back behind house
|
ELE19-00538
| Permanent Service | 3/20/2019 | 3/21/2019 | 3/21/2019 11:25:20 AM | A | PASS |
|
|
Service Inspection requested for 2 new panels. Please call Lynn at ###-#### prior to arrival. Thank you! Phone #: ###-#### Inspection requested via web by Lynn Proctor... p/s ok to connect...fed off existing service gear
|
ELE19-00966
| Permanent Service | 3/21/2019 | 3/21/2019 | 3/21/2019 10:53:51 AM | P | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Shawna Gates...done AM already...changed final to perm service
|
ELE19-00636
| Electrical Rough-In | 3/20/2019 | 3/21/2019 | 3/21/2019 10:52:06 AM | A | PASS |
|
|
8014418543 is the phone number. Need Mid point inspection. Phone #: ###-#### Inspection requested via web by Coulton Main... UL listed equipment 50A breaker in panel...changing 200A to 150A main
|
ELE18-02665
| Electrical Rough-In | 3/20/2019 | 3/21/2019 | 3/21/2019 10:28:45 AM | A | CANC |
|
|
partial final for the kitchen and cafeteria areas please and thank you contact name Rich Bail Phone #: ###-#### Inspection requested via web by Deb Gooden...needed partial final
|
ELE18-02665
| Final | 3/21/2019 | 3/21/2019 | 3/21/2019 10:28:13 AM | A | PART |
|
|
partial final for the kitchen and cafeteria areas please and thank you contact name Rich Bail Phone #: ###-#### Inspection requested via web by Deb Gooden.... partial final for cafeteria and kitchen only
|
ELE19-00966
| Final | 3/20/2019 | 3/21/2019 | 3/21/2019 9:58:49 AM | A | CANC |
|
|
the underground feeder are provided and installed by Idaho power, please remove the feeder issue from our inspection. We have know idea what size they are installing Phone #: ###-#### Inspection requested via web by Shawna Gates... needed permanent service inspection please schedule final when power restored
|
ELE19-00966
| Permanent Service | 3/21/2019 | 3/21/2019 | 3/21/2019 9:56:57 AM | A | PASS |
|
|
the underground feeder are provided and installed by Idaho power, please remove the feeder issue from our inspection. We have know idea what size they are installing Phone #: ###-#### Inspection requested via web by Shawna Gates.... p/s u/g new ok
|
ELE19-00969
| Electrical Rough-In | 3/20/2019 | 3/21/2019 | 3/21/2019 9:22:08 AM | A | PASS |
|
|
master bed room and bathroom Phone #: ###-#### Inspection requested via web by michael hunt... address is 2937 Ithaca rough ok to cover...upstairs master, bath, entry
|
ELE19-00043
| Permanent Service | 3/20/2019 | 3/21/2019 | 3/21/2019 9:05:10 AM | A | PASS |
|
|
We need a service inspection for this building please. Thank you. Phone #: ###-#### Inspection requested via web by Tom Jenkins... p/s o/h new ok
|
ELE16-03107
| ELE-Aging Inspection | 3/21/2019 | 3/21/2019 | 3/21/2019 7:26:03 AM | | FAIL |
|
|
contractor shall schedule needed final if needed further action will be taken by posting correction notice at job requiring inspection within 5 days or fines will be applied
|