MEC18-06112
| Conference | 3/21/2019 | 3/22/2019 | 3/22/2019 4:25:23 PM | P | CANC |
|
|
I work in Nampa, so if the meeting could be at 3:30 or later, that would be ideal. Please call about 30 minutes before arrival so I can meet you in a timely manner. Thank you! Phone #: ###-#### Inspection requested via web by Kaitlin Johnson
|
MEC19-01135
| Final | 3/21/2019 | 3/22/2019 | 3/22/2019 2:26:31 PM | P | NR |
|
|
INSTALLER BRANDAN ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
|
MEC19-00738
| Final | 3/20/2019 | 3/22/2019 | 3/22/2019 2:21:46 PM | P | FAIL |
|
|
Contact Client Tonya at ###-####
Phone #: ###-#### Inspection requested via web by Andrea Grigsby - gas line sediment trap ok - furnace flue fail chimney liner needs to terminate properly out of chimney and have motar gaurd in place then liner/ bvent adapter installed as to be able to run the rest of the flue in double wall per installation specs. flue in unconditoned crawl needs b vent installed through out
|
MEC19-00903
| Final | 3/18/2019 | 3/22/2019 | 3/22/2019 1:46:35 PM | P | PASS |
|
|
installer David ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - furnace ac coil co ok
|
MEC19-01047
| Pressure Test | 3/22/2019 | 3/22/2019 | 3/22/2019 1:16:06 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Frank Marturello - 20lb gas pressure test ok - 5lb flue pressure test ok - tagged meter location
|
MEC19-01047
| Rough-in | 3/22/2019 | 3/22/2019 | 3/22/2019 1:15:25 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Frank Marturello - R/I ok
|
MEC18-01267
| Mec-Aging Inspection | 3/22/2019 | 3/22/2019 | 3/22/2019 1:14:46 PM | | DONE |
|
|
Called LEISURE TIME and left a voice mail for Ashley about their mechanical aging permit. If corrections have been made please schedule inspection with homeowner. Permit will expire after 180 days 8/22/19
|
MEC19-01078
| Final | 3/21/2019 | 3/22/2019 | 3/22/2019 11:04:28 AM | A | PASS |
|
|
Please call Casey on your way and he will meet you there. ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - final ok
|
MEC19-01153
| Final | 3/21/2019 | 3/22/2019 | 3/22/2019 10:58:45 AM | A | PASS |
|
|
Please inspect later AM. Call Tanner on your way. ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
|
MEC19-00581
| Rough-in | 3/21/2019 | 3/22/2019 | 3/22/2019 10:46:35 AM | A | FAIL |
|
|
Request for cover R/I inspection. Please contact job lead Daryl with any questions or concerns. ###-#### Inspection requested via web by Heather Gransbery -
|
MEC19-01157
| Rough-in | 3/21/2019 | 3/22/2019 | 3/22/2019 9:57:47 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek - Man J. needs to be onsite and stamped by the City of Boise
|
MEC19-01157
| Pressure Test | 3/21/2019 | 3/22/2019 | 3/22/2019 9:57:07 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek - 20lb gas pressure test ok -5lb flue pressure test ok - tagged meter location
|
MEC19-01158
| Final | 3/21/2019 | 3/22/2019 | 3/22/2019 9:42:01 AM | A | FAIL |
|
|
door will be unlocked after 9:00 Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek - A/C fuses need to be 15 amp - access door to furnace in bedroom needs to weatherstriped and sealed tight all combustion taken from the outdoors - furnace flue above roof line has holes due to rust and rot and needs replaced
|
MEC18-03214
| Final | 3/21/2019 | 3/22/2019 | 3/22/2019 9:23:44 AM | A | NH |
|
|
Has not returned phone calls or replied to certified letter. Please go by and attempt inspection. Phone #: ###-#### Inspection requested via web by Mary LaFayette - no access to home left notice on front door
|
MEC19-01116
| Final | 3/21/2019 | 3/22/2019 | 3/22/2019 9:07:10 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok
|
MEC19-01095
| Rough-in | 3/21/2019 | 3/22/2019 | 3/22/2019 8:56:47 AM | A | PASS |
|
|
Johnny Phone #: ###-#### - R/I ok - will need to see a 5lb flue test on existing water heater flue that was moved by final
|
MEC19-01135
| Final | 3/20/2019 | 3/22/2019 | 3/21/2019 7:56:21 AM | P | CANC |
|
|
INSTALLER TRAVIS ###-#### Phone #: ###-#### >> Inspection requested via web by Aaron Alandt Inspection cancelled from web by: Aaron Alandt
|