Inspections for the day of: Thursday, March 23, 2006.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-04599 ELE-Aging Inspection3/23/20063/23/20063/29/2006 10:29:57 AM NR
no sign yet at this address
ELE06-00967 Final3/23/20063/23/20063/23/2006 4:12:47 PMPPASS
This work was performed in Apartment #5 at the TOP of the stairs, enter the building doors on the East side of the building and proceed up the stairs. Owner will meet you in the apartment for the tour. We:1)installed a new 20 amp 120 volt circuit to a new GFCI receptacle in the bathroom. 2)re-fed 2 existing dead wall receptacles from an existing circuit using wiremold and installed an AFCI breaker on this existing circuit. 3)replaced 2 existing kitchen receptacles with GFCI receptacles and installed a ground wire. 4)extended an existing switch leg & neutral to a new center light in the bed room using MC cable. 5)fished power down from the existing smoke detector box to a new receptacle in living room.(#6030248wsa). Jman/CRAIG ###-####. THANKS!!! Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
ELE06-00998 Permanent Service3/23/20063/23/20063/23/2006 3:09:24 PMPPART
Mitch -- call 1st for timing; prefer 3PM; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
grounding and outside work ok
P/S O/h R Ok
ELE06-00981 Permanent Service3/22/20063/23/20063/23/2006 2:33:39 PMPPART
Spencer; Phone #: ###-####
outsid meter/main ok and ground is ok
will have concrete encased electrode later.
check inside panel and 4 wires to range and dryer on final.
P/S O/H R Ok for power
ELE06-00997 Temporary Service3/23/20063/23/20063/23/2006 1:47:23 PMPFAIL
Bernice; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
ground rod not flush. no plastick connector on GEC. no nain bonding jumper. dirty gear. thhn not approved for burrial.
ELE06-00991 Electrical Rough-In3/22/20063/23/20063/23/2006 11:20:15 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Dan Surerus
this is suite 265
ELE06-00851 Electrical Rough-In3/22/20063/23/20063/23/2006 10:52:42 AMAPART
Phone #: ###-#### Internet Inspection Request from: Barry Kendall
walls ok
ELE06-00862 Electrical Rough-In3/22/20063/23/20063/23/2006 9:56:29 AMAPASS
need rough in on basement. as late morning as possible. thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH
ELE06-00024 Final3/22/20063/23/20063/23/2006 9:40:41 AMAPASS
homeowner will be home may be working in back yard please go around; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
ELE06-00939 Electrical Rough-In3/22/20063/23/20063/23/2006 9:15:23 AMAPART
jerry - Note: part r/i; Hallways Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
hallways hard lid ok
anop
ELE06-00818 Final3/22/20063/23/20063/23/2006 8:51:35 AMAPASS
Adam; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
final ok with survey for screw inside an nm box
ELE06-00978 Electrical Rough-In3/22/20063/23/20063/23/2006 8:13:59 AMAPART
###-#### Inspection for underground conduit from garage to house; Phone #: ###-#### Internet Inspection Request from: Joe Thomas
underground to garage is ok