Inspections for the day of: Friday, March 23, 2012.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-00786 ELE-Aging Inspection3/23/20123/23/20123/29/2012 1:22:53 PM PASS
Notified electrical contractor if required final inspection
ELE09-00388 ELE-Aging Inspection3/23/20123/23/20123/28/2012 10:13:31 AM PASS
still under construction
ELE11-01434 Final3/23/20123/23/20123/23/2012 2:50:11 PMPPASS
service change final ok
ELE11-01471 ELE-Aging Inspection3/23/20123/23/20123/23/2012 2:41:48 PM PASS
see final
ELE11-01471 Final3/23/20123/23/20123/23/2012 2:41:06 PMPPASS
No electrical work done, contractor wants permit finaled
ELE12-00559 Electrical Rough-In3/23/20123/23/20123/23/2012 2:38:52 PMPPASS
Please call 15min prior for access -- David Phone #: ###-#### rough-in ok cover unattach garage
ELE12-00030 Final3/22/20123/23/20123/23/2012 2:37:33 PMAFAIL
Contact: Mike Peck Phone #: ###-#### >> Inspection requested via web by Deb Gooden NEC 406.11 Tamper resistant receptacles in dwelling units,Need proper over current in A/C disconnect, stap seal tight flex
ELE11-01637 Rough-In Permanent Service3/23/20123/23/20123/23/2012 12:58:49 PMPNR
Service inspection -- Bert Phone #: ###-#### Need RMS sheet from Idaho power, resize bolt for bonding connection to structural steel, bond water and sprinkler system
ELE12-00447 Electrical Rough-In3/23/20123/23/20123/23/2012 12:23:27 PMPPASS
ceiling rough in contact is Sid ###-#### Phone #: ###-#### >> Inspection requested via web by JENNY EMEL rough-in ok cover ceiling grid
ELE12-00608 Conference3/23/20123/23/20123/23/2012 12:01:32 PMAPASS
eric Phone #: ###-#### ok per Daryl to put in am Discussed requiremens for smoke detector circuitry
ELE12-00588 Conference3/20/20123/23/20123/23/2012 9:55:01 AMAPASS
Stacey Phone #: ###-#### Discuss requirements for new addition 2-bedrooms,bathroom, ulitity room
ELE12-00605 Electrical Rough-In3/23/20123/23/20123/23/2012 9:25:24 AMAPASS
Phone #: ###-#### >> Inspection requested via web by John VanZandt rough-in ok cover kitchen remodel
ELE12-00593 Electrical Rough-In3/22/20123/23/20123/23/2012 9:01:26 AMAPASS
Contact: Brian Giacomino Phone #: ###-#### >> Inspection requested via web by Deb Gooden rough-in ok cover walls
ELE12-00517 Temporary Service3/22/20123/23/20123/23/2012 8:42:19 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
ELE12-00482 Temporary Service3/22/20123/23/20123/23/2012 8:37:38 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk t/s u/g n ok
ELE12-00552 Electrical Rough-In3/22/20123/23/20123/23/2012 8:24:19 AMAPASS
Contact: Carl Petteck ###-#### Phone #: ###-#### >> Inspection requested via web by Scott Campbell rough-in ok cover walls
GCE12-00025 GCE-Rough-In3/22/20123/23/20123/23/2012 8:17:32 AMAPASS
###-####
Buried conduit rough-in ok cover trench
ELE11-02907 Final3/16/20123/23/20123/22/2012 3:02:28 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Michael Hagerty final ok
ELE11-02812 Final3/16/20123/23/20123/22/2012 2:29:03 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Michael Hagerty final ok
ELE11-02840 Final3/16/20123/23/20123/22/2012 2:03:04 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Michael Hagerty final ok
ELE11-02813 Final3/16/20123/23/20123/22/2012 1:55:20 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Michael Hagerty final ok
ELE11-02814 Final3/16/20123/23/20123/22/2012 1:54:31 PMAPASS
Phone #: ###-#### >> Inspection requested via web by Michael Hagerty final ok