ELE13-00381
| ELE-Aging Inspection | 3/23/2015 | 3/23/2015 | 3/24/2015 4:22:30 PM | | DONE |
|
|
Waiting on owner
|
ELE12-02592
| ELE-Aging Inspection | 3/23/2015 | 3/23/2015 | 3/24/2015 11:01:56 AM | | DONE |
|
|
Waiting on contractor to schedule
|
ELE12-02616
| ELE-Aging Inspection | 3/23/2015 | 3/23/2015 | 3/24/2015 11:01:29 AM | | DONE |
|
|
Waiting on contractor to schedule
|
ELE14-02707
| Final | 3/23/2015 | 3/23/2015 | 3/23/2015 3:40:56 PM | P | PASS |
|
|
Back porch addition, fence is unlocked to back yard just head on back Phone #: ###-#### Inspection requested via web by TOM BICANDI Back patio final ok
|
ELE15-00754
| Rough-In Permanent Service | 3/23/2015 | 3/23/2015 | 3/23/2015 3:15:13 PM | P | PASS |
|
|
Inspection requested via web by Rowdy Monroe Rough in ok cover p/s u/g n ok
|
ELE15-00199
| Electrical Rough-In | 3/23/2015 | 3/23/2015 | 3/23/2015 2:40:15 PM | P | PASS |
|
|
code #0363 Phone #: ###-#### Inspection requested via web by Eric Schroeder Rough in ok cover
|
ELE14-02827
| Electrical Rough-In | 3/23/2015 | 3/23/2015 | 3/23/2015 2:10:31 PM | P | PASS |
|
|
Russ Phone #: ###-#### All wiring surface mounted in shop in back yard. complete conduit installed in house crawl space. In shop 314.16 handy boxes to be changed where feed through wiring is installed. 358.30(A)- EMT shall be secured with in 3' of boxes. 210.70- An outdoor lighting outlet shall be installed at man door on shop. 406.12(A)- Tamper resistant receptacle outlets shall be installed for all 15 and 20 amp 120 volt circuits. Underground and shop panel rough in ok
|
ELE13-01523
| Final | 3/23/2015 | 3/23/2015 | 3/23/2015 12:59:37 PM | P | PASS |
|
|
Early afternoon please - Eric Phone #: ###-#### Final ok
|
ELE15-00631
| Electrical Rough-In | 3/23/2015 | 3/23/2015 | 3/23/2015 12:32:06 PM | P | PASS |
|
|
Wendy-front proch-please call if have questions Phone #: ###-#### Rough in ok cover
|
ELE15-00692
| Electrical Rough-In | 3/22/2015 | 3/23/2015 | 3/23/2015 10:22:56 AM | A | PASS |
|
|
Please call me 15 min. ahead and I can meet you there. Thanks. Phone #: ###-#### Inspection requested via web by Mark Estep Kitchen remodel rough in ok cover
|
ELE15-00270
| Final | 3/20/2015 | 3/23/2015 | 3/23/2015 10:08:31 AM | A | PASS |
|
|
Homeowner Paul ###-#### Phone #: ###-#### Inspection requested via web by Emmet Bushman Final ok
|
ELE14-02838
| Final | 3/20/2015 | 3/23/2015 | 3/23/2015 10:07:54 AM | A | PASS |
|
|
Homeowner Paul ###-#### Phone #: ###-#### Inspection requested via web by Emmet Bushman Final ok
|
ELE15-00744
| Electrical Rough-In | 3/20/2015 | 3/23/2015 | 3/23/2015 9:40:51 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Steve Craig 20 circuit to future shed not installed yet. 50 amp RV receptacle outlet southside of home rough in ok
|
ELE15-00408
| Electrical Rough-In | 3/20/2015 | 3/23/2015 | 3/23/2015 9:25:18 AM | A | PASS |
|
|
Ceiling inspection call Cody if questions ###-#### Phone #: ###-#### Inspection requested via web by Shane Lott Pharmacy Grid rough in ok cover
|
ELE15-00451
| Final | 3/20/2015 | 3/23/2015 | 3/23/2015 8:45:34 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn 210.12(A)- All outlets located in bedrooms shall have AFCI protection. Unable to located device for spare beds and smokes. 408.4- Each circuit shall be identified. Spare bed and smokes miss labeled.
|