Inspections for the day of: Monday, March 23, 2015.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE15-00753 Final3/23/20153/23/20153/23/2015 3:52:53 PMPPASS
Need final inspection for replacing 400 watt lamps w/LED on outside wall packs. Phone #: ###-#### Inspection requested via web by Alan Lusk ok final
ELE15-00755 Final3/23/20153/23/20153/23/2015 3:10:43 PMPPASS
Need final inspection for replacing all 400 watt outside lights w/LED lamps. Phone #: ###-#### Inspection requested via web by Alan Lusk ok final
ELE15-00730 Temporary Service3/23/20153/23/20153/23/2015 2:41:06 PMPPASS
Darren Phone #: ###-#### t/s u/g n ok
ELE15-00729 Temporary Service3/23/20153/23/20153/23/2015 2:21:50 PMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
ELE15-00440 Permanent Service3/23/20153/23/20153/23/2015 1:44:13 PMPFAIL
Toby is the contact. Permanent service for Fire Pump. Phone #: ###-#### Inspection requested via web by Buster Bowen called, left message, left correction notice, NEC 358.24 there shall not be more than 360 degree total bend in raceway, 110.3(B) shall install liquid tite per instructions
ELE15-00728 Temporary Service3/23/20153/23/20153/23/2015 12:57:02 PMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
ELE14-02715 Final3/20/20153/23/20153/23/2015 12:29:29 PMAPASS
Kevin Phone #: ###-#### ok final
ELE15-00703 Electrical Rough-In3/22/20153/23/20153/23/2015 10:36:59 AMAPASS
Would like an ok to cover walls. Ceiling light placement not finalized yet. Ceiling is already finished and I will just be putting in can lights w/ shower trim. I have just run to the first light. Thanks Todd Owyhee Electric. After 9:00 A.M. if possible Please Phone #: ###-#### Inspection requested via web by todd cline ri ok
ELE15-00553 Rough-In Permanent Service3/23/20153/23/20153/23/2015 10:12:18 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn ri ok, p/s u/g n ok
ELE15-00747 Rough-In Permanent Service3/20/20153/23/20153/23/2015 9:43:19 AMAPASS
please contact ben if any questions Phone #: ###-#### Inspection requested via web by Ben Archibald ri ok, p/s u/g n ok
ELE15-00751 Rough-In Permanent Service3/22/20153/23/20153/23/2015 9:01:58 AMAFAIL
Phone #: ###-#### Inspection requested via web by TOM BICANDI called, left correction notice, BCC shall post ESC card, shall post address, shall not cover wiring prior to inspection, 250.24 and 250.64(C) grounding electrode shall be continuous, 334.23 shall protect nm cable within 6' of attic access, 210.70 shall provide light and switch under stairs5tf
ELE15-00750 Electrical Rough-In3/22/20153/23/20153/23/2015 8:44:17 AMAPASS
Inspect under ground conduit for cover Phone #: ###-#### Inspection requested via web by Robert Schroder ok cover u/g house to garage only
ELE15-00749 Electrical Rough-In3/22/20153/23/20153/23/2015 8:02:44 AMAPASS
Inspect underground conduit for cover Phone #: ###-#### Inspection requested via web by Robert Schroder ok cover u/g house to garage only