Inspections for the day of: Thursday, March 23, 2017.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM16-02128 PLM-Aging Inspection3/23/20173/23/20173/23/2017 3:04:27 PM PASS
PLM16-02128 Sprinkler (Final)3/23/20173/23/20173/23/2017 3:04:14 PMPPASS
PLM17-00838 Final3/22/20173/23/20173/23/2017 2:58:49 PMPPASS
Phone #: ###-#### Inspection requested via web by Marisa Hone
PLM17-00869 Water and/or Sewer3/23/20173/23/20173/23/2017 2:39:46 PMPPASS
Phone #: ###-#### Inspection requested via web by Brett Simmons
PLM17-00869 DOC - Permit Finaled3/23/20173/23/20173/23/2017 2:39:30 PMPPASS
PLM17-00781 Water Heater Final3/20/20173/23/20173/23/2017 2:31:57 PMPCANC
Mr. Hancock has dialysis before 1 pm and after 3 pm. Please call him prior to arrival at ###-####. Phone #: ###-#### Phone #: ###-#### >> Inspection requested via web by Maira Guzman Inspection cancelled from web by: Maira Guzman
PLM17-00853 Final3/22/20173/23/20173/23/2017 2:29:59 PMPPASS
Call half hour before // Randy Phone #: ###-####
PLM16-03049 Final3/23/20173/23/20173/23/2017 1:58:23 PMPFAIL
Clint Phone #: ###-####-master bath.
1. Toilet requires a 2" vent. No vent present.
2. Dishwasher drain must rise to the top of the cabinet and drain down to the disposal.
3. Certify double check.
4. Install a combustion air inlet unrestricted into the attic at the fau. 40 sq in min.
PLM17-00151 Final3/22/20173/23/20173/23/2017 11:46:40 AMAPASS
Please contact Andy with any questions. ###-#### Phone #: ###-#### Inspection requested via web by william bouck
PLM17-00847 Plumbing Rough-in3/22/20173/23/20173/23/2017 11:38:01 AMAFAIL
Phone #: ###-#### Inspection requested via web by Semsudin Konjuhovac.
Failed waste pressure test
PLM17-00852 Water and/or Sewer3/22/20173/23/20173/23/2017 11:08:14 AMAFAIL
Cesar Phone #: ###-####. Water service fittings require two apposing hose clamps on each side of the fitting.
Sewer ok to cover
PLM17-00359 Plumbing Rough-in3/22/20173/23/20173/23/2017 10:30:42 AMAFAIL
Phone #: ###-#### Inspection requested via web by Kristy Watson.
Missing nail plates and plate straps
PLM17-00360 Plumbing Rough-in3/22/20173/23/20173/23/2017 10:30:10 AMAFAIL
Phone #: ###-#### Inspection requested via web by Kristy Watson.
Missing nail plates and plate straps.
PLM17-00787 Final3/22/20173/23/20173/23/2017 10:11:58 AMAFAIL
Contact Jason with any questions Phone #: ###-#### Inspection requested via web by Justin Whitt.
1. Gas pressure test needs 30 psi gauge with 20 psi test.
2. Perm cap the 1/2" gas line at the unit heater.
3. Verify nail-ons are pennitraiting wood through the sheetrock.
4. Gap pressure test should have two gas valves at the pressure line.
PLM17-00827 Final3/22/20173/23/20173/23/2017 10:09:02 AMAFAIL
Contact Jason with any questions Phone #: ###-#### Inspection requested via web by Justin Whitt.
1. Install backflow assembly for the tent washer. rp.
2. Dishwasher drains needs to have an airbreak.
3. Install a pressure tank at the water heater.
4. Fix leaks in the water line.
2. Install
PLM17-00773 Sprinkler (Final)3/22/20173/23/20173/23/2017 9:17:33 AMAFAIL
David Phone #: ###-####. Backflow not pressurized or certified.
PLM16-04144 Groundwork3/22/20173/23/20173/23/2017 9:02:49 AMAPART
CHRIS IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER.
kitchen and grease ok to cover
PLM16-04121 Final3/22/20173/23/20173/23/2017 8:50:01 AMAFAIL
3303 ENTER Phone #: ###-#### Inspection requested via web by Ann Marie Reyes. Certify backflow.
PLM17-00597 Groundwork3/23/20173/23/20173/23/2017 7:52:37 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Ann Marie Reyes Inspection cancelled from web by: Ann Marie Reyes