PLM17-02819
| PLM-Aging Inspection | 3/23/2018 | 3/23/2018 | 3/26/2018 10:45:45 AM | | PEND |
|
|
not framed yet
|
PLM16-00455
| Final | 3/22/2018 | 3/23/2018 | 3/23/2018 4:56:58 PM | P | PASS |
|
|
Todd Phone #: ###-####
|
PLM18-01195
| Water and/or Sewer | 3/23/2018 | 3/23/2018 | 3/23/2018 4:22:24 PM | P | FAIL |
|
|
Arden Davis is owner ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart. Provide an airgap where the 2" drains into the 4" to prevent a cross connection. Perm cap the old drain
|
PLM18-01194
| Plumbing Rough-in | 3/23/2018 | 3/23/2018 | 3/23/2018 4:04:31 PM | P | PASS |
|
|
Code for door 2569 Phone #: ###-#### Inspection requested via web by steven smith
|
PLM17-01620
| Final | 3/20/2018 | 3/23/2018 | 3/23/2018 3:41:11 PM | P | PASS |
|
|
Please call Katie Engels prior to inspection at ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
PLM18-00922
| Plumbing Rough-in | 3/23/2018 | 3/23/2018 | 3/23/2018 3:37:54 PM | P | FAIL |
|
|
Allen Phone #: ###-####. 1. An accessible cleanout is required next to the double santee. 2. All full size cleanouts more than 5 feet from the crawl access is required to be above the floor.
|
PLM18-01141
| Final | 3/23/2018 | 3/23/2018 | 3/23/2018 3:22:48 PM | P | FAIL |
|
|
Please call Johnny with questions ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Jennifer Alcalaf. 1. Cap all unused outlets including gas, water and waste. 2. Lav supplies cannot be joined. Install one supply that will reach the faucet or extend the water lines closer to the sink. 3. Toggle the equipment on wheels that have gas supply. 4. Provide an airgap on the indirect waste to the prep sink..
|
PLM18-00237
| Final | 3/23/2018 | 3/23/2018 | 3/23/2018 3:11:34 PM | P | NH |
|
|
3rd floor. Exit to the left out of the elevators, 1st door on left past the restrooms. Phone #: ###-#### Inspection requested via web by Jason Adams. No Access
|
PLM18-01196
| Water Heater Final | 3/23/2018 | 3/23/2018 | 3/23/2018 1:31:14 PM | P | PASS |
|
|
Danielle Nielsen will be home. ###-#### Phone #: ###-#### Inspection requested via web by Heidi Lukecart
|
PLM18-01025
| Final | 3/23/2018 | 3/23/2018 | 3/23/2018 1:12:56 PM | P | PASS |
|
|
Call Ryan on way - ###-#### Phone #: ###-#### Inspection requested via web by Xanti Berria
|
PLM18-01185
| Water and/or Sewer | 3/23/2018 | 3/23/2018 | 3/23/2018 11:23:55 AM | A | PASS |
|
|
Water service ok to cover. Re-pipe not ready. Verify PVB ceritication prior to final
|
PLM18-01119
| Final | 3/19/2018 | 3/23/2018 | 3/23/2018 10:54:58 AM | A | FAIL |
|
|
Please call Nancy prior to showing up ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby. 1. Install a drain pan under the water heater and pipe outside. 2. Pipe the t&p outside from 6" to 18" above the ground. 3. Verify co detectors. 4. Don't cover combustion air or provide new.
|
PLM17-05090
| Final | 3/22/2018 | 3/23/2018 | 3/23/2018 10:21:56 AM | A | PASS |
|
|
Code 3283 Phone #: ###-#### Inspection requested via web by Jason Gonzalez
|
PLM18-00919
| Plumbing Rough-in | 3/22/2018 | 3/23/2018 | 3/23/2018 9:52:32 AM | A | PASS |
|
|
Alan Phone #: ###-####
|
PLM18-01156
| DOC - Permit Finaled | 3/23/2018 | 3/23/2018 | 3/23/2018 9:40:09 AM | P | PASS |
|
|
complete
|
PLM18-01193
| Plumbing Rough-in | 3/23/2018 | 3/23/2018 | 3/23/2018 9:38:01 AM | P | PASS |
|
|
if questions call Ryan @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann nicue sink rin
|
PLM18-01160
| Plumbing Rough-in | 3/22/2018 | 3/23/2018 | 3/23/2018 8:58:46 AM | A | PASS |
|
|
Phone #: 2089412422 >> Inspection requested via mobile web by Brandon
|