ELE06-00756
| Electrical Rough-In | 3/24/2006 | 3/24/2006 | 3/24/2006 4:29:17 PM | P | FAIL |
|
|
This inspection was missed on the first request, and we are requesting a re-inspection.; Phone #: ###-#### Internet Inspection Request from: Justin Metcalf called contr, left corr notice, fee due, 312.5 all conductors entering enclosures shall have abrasion protection, 110.12(C) there shall be no bent parts (door hinges), 408.4 circuit directory shall be provided, 406(B)(2)(a)receptacle shall have weatherproof cover for in-use, 250.53(G) electrode shall not be driven over 45 degree angle
|
ELE05-04100
| Final | 3/24/2006 | 3/24/2006 | 3/24/2006 3:54:35 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot called contr, left corr notice, 314.23(C) receptacle outlets shall be securely fastened in place, 210.52(A) receptacles shall be added in kitchen countertop area and library room, 406.8(C) receptacles shall not be installed over a bathtub
|
ELE05-03919
| Permanent Service | 3/23/2006 | 3/24/2006 | 3/24/2006 3:10:48 PM | P | PASS |
|
|
PLEASE CALL DAVE BRADSHAW TO MEET INSPECTOR ON SITE; Phone #: ###-#### Internet Inspection Request from: Randy Vail looked at fittings, ok, p/s, unit 7009 ok for meter
|
ELE06-01010
| Temporary Service | 3/24/2006 | 3/24/2006 | 3/24/2006 2:29:48 PM | P | PASS |
|
|
overhead service; Phone #: ###-#### Internet Inspection Request from: Latisha Peltier t/s o/h n ok
|
ELE06-00915
| Final | 3/24/2006 | 3/24/2006 | 3/24/2006 1:44:58 PM | P | PASS |
|
|
dave ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie called contr to put bushing on gec, ok to final
|
ELE06-01016
| Permanent Service | 3/24/2006 | 3/24/2006 | 3/24/2006 1:03:22 PM | P | FAIL |
|
|
kelley falin ###-#### or ###-#### called contr, left corr notice,240.81 circuit bkr handle shall be on in up position, 312.5 abrasion protection shall be provided for all conductors entering enclosures,250.24(1) gndg electrode conductor shall connect to grounded conductor terminal, 314.15(A) coupling shall be listed for use in wet location, 230.66 service equip shall be marked to identify as being suitable for use as service equipment
|
ELE06-00965
| Temporary Service | 3/23/2006 | 3/24/2006 | 3/24/2006 10:45:45 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 3/23/2006 at 2:41:47 PM. Contact: ###-####. corr made, t/s u/g n ok
|
ELE06-00966
| Temporary Service | 3/23/2006 | 3/24/2006 | 3/24/2006 10:45:04 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 3/23/2006 at 3:00:27 PM. Contact: ###-####. corr made, t/s u/g n ok
|
ELE06-00963
| Temporary Service | 3/23/2006 | 3/24/2006 | 3/24/2006 10:44:28 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 3/23/2006 at 2:40:47 PM. Contact: ###-####. corr made, t/s u/g n ok
|
ELE06-00962
| Temporary Service | 3/23/2006 | 3/24/2006 | 3/24/2006 10:42:15 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 3/23/2006 at 2:40:16 PM. Contact: ###-####. corr made, t/s u/g n ok
|
ELE06-00964
| Temporary Service | 3/23/2006 | 3/24/2006 | 3/24/2006 10:40:59 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 3/23/2006 at 2:41:17 PM. Contact: ###-####. corr made, t/s u/g n ok
|
ELE06-00961
| Temporary Service | 3/23/2006 | 3/24/2006 | 3/24/2006 10:40:16 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 3/23/2006 at 2:36:56 PM. Contact: ###-####. corr made, t/s u/g n ok
|
ELE05-04649
| ELE-Aging Inspection | 3/24/2006 | 3/24/2006 | 3/24/2006 9:39:07 AM | | DONE |
|
|
see final
|
ELE05-04649
| Final | 3/24/2006 | 3/24/2006 | 3/24/2006 9:38:48 AM | A | PASS |
|
|
ok to final
|
ELE06-00078
| ELE-Aging Inspection | 3/24/2006 | 3/24/2006 | 3/24/2006 9:24:07 AM | | DONE |
|
|
checked job, suc
|
ELE06-00790
| Electrical Rough-In | 3/22/2006 | 3/24/2006 | 3/24/2006 8:49:21 AM | A | PART |
|
|
RI partial walls. Thanks!; Phone #: ###-#### Internet Inspection Request from: Heather Packer met contr, left corr notice, 110.26(F)(1)(a) the space equal to the width and depth of the equipment and extending from the floor to the structural ceiling shall be dedicated to the electrical installation, BCC u/g shall be inspected before cover, interior walls except at panel area ok to cover anop
|