Inspections for the day of: Wednesday, March 24, 2010.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-00596 Permanent Service3/24/20103/24/20103/25/2010 8:30:24 AMPCANC
Power has been off for over 1 year and Idaho Power will not hook up without a permit. Lock box code is 9365 Inspection requested from web by: Dan Rohl Phone #: ###-#### see fail response on 3-25-10
ESC09-00788 General Inspection3/24/20103/24/20103/24/2010 3:57:00 PMPPASS
looked ok
ESC09-00763 General Inspection3/24/20103/24/20103/24/2010 3:55:50 PMPPASS
looked ok
ESC09-00560 General Inspection3/24/20103/24/20103/24/2010 3:55:11 PMPPASS
looked ok
ESC09-00773 General Inspection3/24/20103/24/20103/24/2010 3:54:26 PMPPASS
looked ok
ELE09-01893 Final3/24/20103/24/20103/24/2010 3:53:28 PMPPASS
please call me half an hour before inspection to insure access Thanks Shaun ###-#### Inspection requested from web by: Shaun Kirkman Phone #: ###-#### met contractor, ok to final
ELE10-00210 Electrical Rough-In3/24/20103/24/20103/24/2010 3:18:20 PMPNH
dan Phone #: ###-#### called, left correction notice, NEC 300.4(D) edge of nm cable shall be 1 1/4" from edge of framing member, NOTE corrections shall be made in 5 working days
ELE10-00271 Final3/24/20103/24/20103/24/2010 2:21:43 PMPPASS
please call 30 min prior to meet you for access//Mike ###-#### ok to final, no esc this project
ELE10-00598 Electrical Rough-In3/24/20103/24/20103/24/2010 1:37:20 PMPFAIL
robert Phone #: ###-#### called, left correction notice, NEC 314.17(C) nm shall be stapled within 8" of box, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 314.20 if combustile material, bobxes shall be flush with finished surface, 225.31 shall supply building disconnect, 110.11 shall not use any material that has a deteriorating effect on conductors, NOTE corrections shall be made within 5 working days
ELE10-00587 Permanent Service3/23/20103/24/20103/24/2010 12:50:57 PMPPASS
mitch - please call 1/2 hr prior Phone #: ###-#### p/s o/h rec ok, will call for final, no esc this project
ELE10-00590 Conference3/23/20103/24/20103/24/2010 11:33:23 AMADONE
Please call Jimmy @ ###-#### prior to arrival. Inspection requested from web by: John Edwards Phone #: ###-#### looked at and talked about receptacle at propane dispenser
ELE10-00074 Final3/23/20103/24/20103/24/2010 10:43:02 AMAPART
joe Phone #: ###-#### 4th, 5th floors ok to final, will do 1st later no esc this project
ELE10-00074 Electrical Rough-In3/23/20103/24/20103/24/2010 10:15:46 AMAPASS
joe Phone #: ###-#### ri ok 2414, 2507, 2511, no esc
ELE10-00016 Electrical Rough-In3/23/20103/24/20103/24/2010 9:45:40 AMAPASS
Small building in the back. Not the castle (unfortunately) Inspection requested from web by: Greg Idsinga Phone #: ###-#### called, ric ok
ELE10-00594 Rough-In Permanent Service3/24/20103/24/20103/24/2010 8:51:48 AMAFAIL
Inspection requested from web by: Emmet Bushman Phone #: ###-#### called, left correction notice, NEC 300.14 shall provide at least 6" free conductor length in box, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 210.52(A)(1)(2) shall provide receptacle in wall over 2' and such that no point is over 6' from outlet along wall line, NOTE corrections shall be made in 5 working days
ELE10-00591 Final3/23/20103/24/20103/24/2010 8:05:33 AMAPASS
Inspection requested from web by: Daryl DeGrange Phone #: ###-#### ok to final, no esc this project
ELE10-00560 Permanent Service3/23/20103/24/20103/23/2010 2:02:14 PMAPASS
Phone #: ###-#### p/s o/h rec ok, no esc this project