ELE10-00596
| Permanent Service | 3/24/2010 | 3/24/2010 | 3/25/2010 8:30:24 AM | P | CANC |
|
|
Power has been off for over 1 year and Idaho Power will not hook up without a permit. Lock box code is 9365 Inspection requested from web by: Dan Rohl Phone #: ###-#### see fail response on 3-25-10
|
ESC09-00788
| General Inspection | 3/24/2010 | 3/24/2010 | 3/24/2010 3:57:00 PM | P | PASS |
|
|
looked ok
|
ESC09-00763
| General Inspection | 3/24/2010 | 3/24/2010 | 3/24/2010 3:55:50 PM | P | PASS |
|
|
looked ok
|
ESC09-00560
| General Inspection | 3/24/2010 | 3/24/2010 | 3/24/2010 3:55:11 PM | P | PASS |
|
|
looked ok
|
ESC09-00773
| General Inspection | 3/24/2010 | 3/24/2010 | 3/24/2010 3:54:26 PM | P | PASS |
|
|
looked ok
|
ELE09-01893
| Final | 3/24/2010 | 3/24/2010 | 3/24/2010 3:53:28 PM | P | PASS |
|
|
please call me half an hour before inspection to insure access Thanks Shaun ###-#### Inspection requested from web by: Shaun Kirkman Phone #: ###-#### met contractor, ok to final
|
ELE10-00210
| Electrical Rough-In | 3/24/2010 | 3/24/2010 | 3/24/2010 3:18:20 PM | P | NH |
|
|
dan Phone #: ###-#### called, left correction notice, NEC 300.4(D) edge of nm cable shall be 1 1/4" from edge of framing member, NOTE corrections shall be made in 5 working days
|
ELE10-00271
| Final | 3/24/2010 | 3/24/2010 | 3/24/2010 2:21:43 PM | P | PASS |
|
|
please call 30 min prior to meet you for access//Mike ###-#### ok to final, no esc this project
|
ELE10-00598
| Electrical Rough-In | 3/24/2010 | 3/24/2010 | 3/24/2010 1:37:20 PM | P | FAIL |
|
|
robert Phone #: ###-#### called, left correction notice, NEC 314.17(C) nm shall be stapled within 8" of box, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 314.20 if combustile material, bobxes shall be flush with finished surface, 225.31 shall supply building disconnect, 110.11 shall not use any material that has a deteriorating effect on conductors, NOTE corrections shall be made within 5 working days
|
ELE10-00587
| Permanent Service | 3/23/2010 | 3/24/2010 | 3/24/2010 12:50:57 PM | P | PASS |
|
|
mitch - please call 1/2 hr prior Phone #: ###-#### p/s o/h rec ok, will call for final, no esc this project
|
ELE10-00590
| Conference | 3/23/2010 | 3/24/2010 | 3/24/2010 11:33:23 AM | A | DONE |
|
|
Please call Jimmy @ ###-#### prior to arrival. Inspection requested from web by: John Edwards Phone #: ###-#### looked at and talked about receptacle at propane dispenser
|
ELE10-00074
| Final | 3/23/2010 | 3/24/2010 | 3/24/2010 10:43:02 AM | A | PART |
|
|
joe Phone #: ###-#### 4th, 5th floors ok to final, will do 1st later no esc this project
|
ELE10-00074
| Electrical Rough-In | 3/23/2010 | 3/24/2010 | 3/24/2010 10:15:46 AM | A | PASS |
|
|
joe Phone #: ###-#### ri ok 2414, 2507, 2511, no esc
|
ELE10-00016
| Electrical Rough-In | 3/23/2010 | 3/24/2010 | 3/24/2010 9:45:40 AM | A | PASS |
|
|
Small building in the back. Not the castle (unfortunately) Inspection requested from web by: Greg Idsinga Phone #: ###-#### called, ric ok
|
ELE10-00594
| Rough-In Permanent Service | 3/24/2010 | 3/24/2010 | 3/24/2010 8:51:48 AM | A | FAIL |
|
|
Inspection requested from web by: Emmet Bushman Phone #: ###-#### called, left correction notice, NEC 300.14 shall provide at least 6" free conductor length in box, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 210.52(A)(1)(2) shall provide receptacle in wall over 2' and such that no point is over 6' from outlet along wall line, NOTE corrections shall be made in 5 working days
|
ELE10-00591
| Final | 3/23/2010 | 3/24/2010 | 3/24/2010 8:05:33 AM | A | PASS |
|
|
Inspection requested from web by: Daryl DeGrange Phone #: ###-#### ok to final, no esc this project
|
ELE10-00560
| Permanent Service | 3/23/2010 | 3/24/2010 | 3/23/2010 2:02:14 PM | A | PASS |
|
|
Phone #: ###-#### p/s o/h rec ok, no esc this project
|