ELE13-00375
| ELE-Aging Inspection | 3/24/2015 | 3/24/2015 | 3/30/2015 8:26:49 AM | | DONE |
|
|
Still under construction
|
ELE13-00214
| Final | 3/24/2015 | 3/24/2015 | 3/24/2015 4:20:43 PM | P | PASS |
|
|
Drove by corrections made. Final ok
|
ELE15-00590
| Final | 3/24/2015 | 3/24/2015 | 3/24/2015 4:17:54 PM | P | CANC |
|
|
Contact: Brian Gee.... Perm. service ; Final inspections please Phone #: ###-#### Inspection requested via web by Deb Gooden Need to reschedule final to ensure GFCI and lighting working properly.
|
ELE15-00590
| Permanent Service | 3/24/2015 | 3/24/2015 | 3/24/2015 4:17:12 PM | P | PASS |
|
|
Contact: Brian Gee.... Perm. service ; Final inspections please Phone #: ###-#### Inspection requested via web by Deb Gooden p/s o/h n ok
|
ELE15-00765
| Conference | 3/23/2015 | 3/24/2015 | 3/24/2015 3:29:41 PM | P | DONE |
|
|
Please give me a half hour heads up so I can meet you out there. Thanks Phone #: ###-#### Inspection requested via web by Clay Morgan Discussed requirements for service change to eliminate tripping due to overload on house panel that feeds community laundry room. Shall up size service to house panel, fuse down feeders to appartments due to SER cable sub feeds, raise riser over flat roof, relocate house panel in laundry room panel to provide work space, did permit search no other recent permits exist. Noticed dated Dec 2013 NM cable ran outdoors under walkway roof to carport. Contractor to inform building management all needs replaced with listed materials for locations.
|
ELE14-03132
| Electrical Rough-In | 3/24/2015 | 3/24/2015 | 3/24/2015 2:46:55 PM | P | PASS |
|
|
Please inspect underground on gate wiring Phone #: ###-#### Inspection requested via web by ERIC CENTERS Underground for gate east side rough in ok cover
|
ELE15-00779
| Permanent Service | 3/24/2015 | 3/24/2015 | 3/24/2015 2:30:15 PM | P | PASS |
|
|
2nd rod and plumbing bond at water heater between hot and cold for final. p/s u/g rec ok
|
ELE15-00779
| Final | 3/24/2015 | 3/24/2015 | 3/24/2015 2:29:01 PM | P | CANC |
|
|
This is a foreclosure.. I walked the house and opened the service to check wires and terminations. I need to have power to check remainder of house. Please call me with any questions. 208 ###-#### Todd Please call for access.. Phone #: ###-#### Inspection requested via web by Kendra Lanham Needed permenant service
|
ELE15-00757
| Rough-In Permanent Service | 3/24/2015 | 3/24/2015 | 3/24/2015 2:09:55 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|
ELE15-00087
| Electrical Rough-In | 3/24/2015 | 3/24/2015 | 3/24/2015 1:51:06 PM | P | PASS |
|
|
Ditch inspection // Rocky Phone #: ###-#### Underground to shed rough in ok cover
|
ELE15-00470
| Final | 3/24/2015 | 3/24/2015 | 3/24/2015 1:17:12 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by kendall bender Final ok
|
ELE13-00824
| Final | 3/24/2015 | 3/24/2015 | 3/24/2015 12:39:26 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
ELE15-00354
| Final | 3/24/2015 | 3/24/2015 | 3/24/2015 12:24:25 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov 210.12(A)- All 15 and 20 amp 120 volt outlets shall have AFCI protection.
|
ELE15-00762
| Temporary Service | 3/23/2015 | 3/24/2015 | 3/24/2015 11:13:37 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Eric Schroeder t/s u/g n ok
|
ELE15-00672
| Rough-In Permanent Service | 3/23/2015 | 3/24/2015 | 3/24/2015 11:00:07 AM | A | PASS |
|
|
Please contact Cody ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Tracy Robertson Rough in ok cover p/s u/g n ok
|
ELE15-00757
| Final | 3/24/2015 | 3/24/2015 | 3/24/2015 10:26:03 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn Inspection cancelled from web by: Darryn Coburn
|
ELE15-00757
| Rough-In Permanent Service | 3/23/2015 | 3/24/2015 | 3/24/2015 10:10:22 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn 210.52(A)- Wall in nook, receptacle outlet shall be located within 6' of door to hall. 210.52(I)- Foyer wall with 3' minimum length shall have receptacle outlet installed. 334.23 NM cable located within 7' of attic access shall be protected with guard strips.
|
ELE15-00768
| Rough-In Permanent Service | 3/23/2015 | 3/24/2015 | 3/24/2015 9:37:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jerry Moore rough in ok cover p/s u/g n ok
|
ELE15-00440
| Permanent Service | 3/23/2015 | 3/24/2015 | 3/24/2015 8:37:13 AM | A | PASS |
|
|
Toby is the contact. Fire pump service. Phone #: ###-#### Inspection requested via web by Buster Bowen Corrections made p/s u/g n ok
|
ELE15-00461
| Final | 3/23/2015 | 3/24/2015 | 3/24/2015 8:10:05 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tom Betty Final ok
|