ELE13-02179
| ELE-Aging Inspection | 3/24/2016 | 3/24/2016 | 3/24/2016 1:42:48 PM | | DONE |
|
|
too busy
|
ELE16-00506
| Electrical Rough-In | 3/23/2016 | 3/24/2016 | 3/24/2016 1:41:51 PM | P | PASS |
|
|
We are requesting an additional inspection for stair tower 2 for tomorrow 3/24/16 in the afternoon. Our contacts are Bobbie @ ###-#### or Tony @ ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Clint Tate stairwell 2, north and west side conduit and boxes in walls r/i ok ALSO: Tony wants to know why they can't drive ground rods inside of bldg. to ground generator frame and they want to install nuecler exits in stairwell.
|
ELE13-01503
| Final | 3/24/2016 | 3/24/2016 | 3/24/2016 12:39:31 PM | P | PASS |
|
|
Maria Phone #: ###-#### corrections made final ok
|
ELE16-00222
| Electrical Rough-In | 3/24/2016 | 3/24/2016 | 3/24/2016 12:26:33 PM | P | PASS |
|
|
ceiling; Andy Phone #: ###-#### r/i ok 2nd floor t grid north half of large area. Also r/i ok 1st floor hard lid at back entry. Also asked Andy to relocate 2 raceways in 2nd flr server room in front of HVAC vav control box in ceiling to meet 110.26(A)(1) NEC
|
ELE15-03491
| Final | 3/24/2016 | 3/24/2016 | 3/24/2016 11:08:40 AM | P | PASS |
|
|
Rocky Phone #: ###-#### final ok
|
ESC16-00289
| Random Inspection | 3/24/2016 | 3/24/2016 | 3/24/2016 10:44:32 AM | P | PASS |
|
|
tracking inspection clean no track out
|
ELE16-00917
| Temporary Service | 3/23/2016 | 3/24/2016 | 3/24/2016 10:42:44 AM | A | FAIL |
|
|
located on back north east corner of lot (behind house) Phone #: ###-#### Inspection requested via web by Richard Gratiot As per Idaho Power;6x6 post minimum for overhead temp. services. NEC 230.24(B)- 10 foot minimum height to service entrance conductors
|
ESC15-01071
| Tracking Control | 3/24/2016 | 3/24/2016 | 3/24/2016 10:19:44 AM | P | DONE |
|
|
track out-Spoke with Big D to let them know they have some track out of mud. Jim will get it cleaned up now
|
ELE16-00506
| Electrical Rough-In | 3/23/2016 | 3/24/2016 | 3/24/2016 10:15:13 AM | A | PASS |
|
|
We are requesting a underground inspection for stair tower 2 for tomorrow 3/24/16 in the AM. Our contacts are Bobbie @ ###-#### or Tony @ ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Clint Tate r/i stairwell 2 walls and north wall up to 4 foot ok NOTE;as of today look for inspector set in Big D trailer. See highlighted areas
|
ELE15-01617
| Electrical Rough-In | 3/23/2016 | 3/24/2016 | 3/24/2016 9:50:19 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton r/i ok entire north exterior wall (living rm. wall)
|
ELE15-04035
| Electrical Rough-In | 3/24/2016 | 3/24/2016 | 3/24/2016 9:12:53 AM | P | PASS |
|
|
Contact is Robert Gates. Location is Main Street and Boise River Bridge. Please call 15 minutes prior to arrival. Phone #: ###-#### Inspection requested via web by Scott Campbell r/i underground raceways to new lights on west bridge ok
|
ELE16-00117
| Final | 3/23/2016 | 3/24/2016 | 3/24/2016 8:52:30 AM | A | FAIL |
|
|
Kenny Phone #: ###-#### 110.24-Available Fault current shall be posted at main disconnect. 210.63-a 120 volt receptacle outlet shall be installed within 25 foot of HVAC equipment.
|
ELE16-00603
| Final | 3/23/2016 | 3/24/2016 | 3/24/2016 8:15:59 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kelly Felin final ok
|
ELE16-00911
| Electrical Rough-In | 3/24/2016 | 3/24/2016 | 3/24/2016 6:31:21 AM | A | CANC |
|
|
2nd floor office ceilings & walls; call when in route if possible. Phone #: ###-#### >> Inspection requested via web by Steve McCloy Inspection cancelled from web by: Steve McCloy
|
ELE16-00911
| Electrical Rough-In | 3/23/2016 | 3/24/2016 | 3/24/2016 6:29:03 AM | A | CANC |
|
|
Call Steve when in route if possible. Phone #: ###-#### >> Inspection requested via web by Steve McCloy Inspection cancelled from web by: Steve McCloy
|