Inspections for the day of: Thursday, March 24, 2016.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRex Boyles
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02179 ELE-Aging Inspection3/24/20163/24/20163/24/2016 1:42:48 PM DONE
too busy
ELE16-00506 Electrical Rough-In3/23/20163/24/20163/24/2016 1:41:51 PMPPASS
We are requesting an additional inspection for stair tower 2 for tomorrow 3/24/16 in the afternoon. Our contacts are Bobbie @ ###-#### or Tony @ ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Clint Tate stairwell 2, north and west side conduit and boxes in walls r/i ok ALSO: Tony wants to know why they can't drive ground rods inside of bldg. to ground generator frame and they want to install nuecler exits in stairwell.
ELE13-01503 Final3/24/20163/24/20163/24/2016 12:39:31 PMPPASS
Maria Phone #: ###-#### corrections made final ok
ELE16-00222 Electrical Rough-In3/24/20163/24/20163/24/2016 12:26:33 PMPPASS
ceiling; Andy Phone #: ###-#### r/i ok 2nd floor t grid north half of large area. Also r/i ok 1st floor hard lid at back entry. Also asked Andy to relocate 2 raceways in 2nd flr server room in front of HVAC vav control box in ceiling to meet 110.26(A)(1) NEC
ELE15-03491 Final3/24/20163/24/20163/24/2016 11:08:40 AMPPASS
Rocky Phone #: ###-#### final ok
ESC16-00289 Random Inspection3/24/20163/24/20163/24/2016 10:44:32 AMPPASS
tracking inspection clean no track out
ELE16-00917 Temporary Service3/23/20163/24/20163/24/2016 10:42:44 AMAFAIL
located on back north east corner of lot (behind house) Phone #: ###-#### Inspection requested via web by Richard Gratiot As per Idaho Power;6x6 post minimum for overhead temp. services. NEC 230.24(B)- 10 foot minimum height to service entrance conductors
ESC15-01071 Tracking Control3/24/20163/24/20163/24/2016 10:19:44 AMPDONE
track out-Spoke with Big D to let them know they have some track out of mud. Jim will get it cleaned up now
ELE16-00506 Electrical Rough-In3/23/20163/24/20163/24/2016 10:15:13 AMAPASS
We are requesting a underground inspection for stair tower 2 for tomorrow 3/24/16 in the AM. Our contacts are Bobbie @ ###-#### or Tony @ ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Clint Tate r/i stairwell 2 walls and north wall up to 4 foot ok NOTE;as of today look for inspector set in Big D trailer. See highlighted areas
ELE15-01617 Electrical Rough-In3/23/20163/24/20163/24/2016 9:50:19 AMAPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton r/i ok entire north exterior wall (living rm. wall)
ELE15-04035 Electrical Rough-In3/24/20163/24/20163/24/2016 9:12:53 AMPPASS
Contact is Robert Gates. Location is Main Street and Boise River Bridge. Please call 15 minutes prior to arrival. Phone #: ###-#### Inspection requested via web by Scott Campbell r/i underground raceways to new lights on west bridge ok
ELE16-00117 Final3/23/20163/24/20163/24/2016 8:52:30 AMAFAIL
Kenny Phone #: ###-#### 110.24-Available Fault current shall be posted at main disconnect. 210.63-a 120 volt receptacle outlet shall be installed within 25 foot of HVAC equipment.
ELE16-00603 Final3/23/20163/24/20163/24/2016 8:15:59 AMAPASS
Phone #: ###-#### Inspection requested via web by Kelly Felin final ok
ELE16-00911 Electrical Rough-In3/24/20163/24/20163/24/2016 6:31:21 AMACANC
2nd floor office ceilings & walls; call when in route if possible. Phone #: ###-#### >> Inspection requested via web by Steve McCloy Inspection cancelled from web by: Steve McCloy
ELE16-00911 Electrical Rough-In3/23/20163/24/20163/24/2016 6:29:03 AMACANC
Call Steve when in route if possible. Phone #: ###-#### >> Inspection requested via web by Steve McCloy Inspection cancelled from web by: Steve McCloy