MEC13-00244
| Mec-Aging Inspection | 3/25/2014 | 3/25/2014 | 3/25/2014 4:45:06 PM | | PEND |
|
|
Called, they are going to try and get it scheduled
|
MEC13-00232
| Mec-Aging Inspection | 3/25/2014 | 3/25/2014 | 3/25/2014 4:42:20 PM | | PEND |
|
|
called, they are going to try to get it scheduled
|
MEC12-03516
| Mec-Aging Inspection | 3/25/2014 | 3/25/2014 | 3/25/2014 4:32:02 PM | | PEND |
|
|
Called they are going to try to get it scheduled
|
MEC13-01099
| Mec-Aging Inspection | 3/25/2014 | 3/25/2014 | 3/25/2014 4:24:36 PM | | PEND |
|
|
Called, They are going to try to get it scheduled.
|
MEC14-01081
| Final | 3/25/2014 | 3/25/2014 | 3/25/2014 4:16:49 PM | P | NR |
|
|
LATE AS POSSIBLE Phone #: ###-####
|
MEC14-01114
| Final | 3/25/2014 | 3/25/2014 | 3/25/2014 3:36:24 PM | P | PASS |
|
|
Pressure test only, mid to late afternoon. Thanks. Phone #: ###-#### >> Inspection requested via web by April Thomas - 20LB gas pressure test pass.
|
MEC14-00887
| Final | 3/25/2014 | 3/25/2014 | 3/25/2014 3:00:01 PM | P | PASS |
|
|
Call Eric @ ###-#### with any installation issues/questions Phone #: ###-#### >> Inspection requested via web by Angie Maguire
|
MEC14-01101
| Pressure Test | 3/24/2014 | 3/25/2014 | 3/25/2014 2:35:35 PM | P | PASS |
|
|
gaspiper miguel ###-#### Phone #: ###-#### >> Inspection requested via web by Dustin Rich - 20LB gas pressure test pass.
|
MEC14-01025
| Rough-in | 3/25/2014 | 3/25/2014 | 3/25/2014 2:20:03 PM | P | PASS |
|
|
>> Inspection requested via web by claude croy
|
MEC14-01101
| Final | 3/24/2014 | 3/25/2014 | 3/25/2014 2:16:03 PM | P | CANC |
|
|
installer cody ###-#### Phone #: ###-#### >> Inspection requested via web by Dustin Rich Inspection cancelled from web by: Dustin Rich
|
MEC13-05508
| Final | 3/25/2014 | 3/25/2014 | 3/25/2014 2:08:15 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dustin Rich
|
MEC14-01093
| Rough-in | 3/24/2014 | 3/25/2014 | 3/25/2014 1:42:22 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Krista Boss - Need approved manual J on-site, Service access in front of equipment in attic needs to extend 30" in front of equipment & to the attic access
|
MEC14-01093
| Pressure Test | 3/24/2014 | 3/25/2014 | 3/25/2014 1:40:40 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Krista Boss - 20LB gas preesure test pass
|
MEC14-01082
| Conference | 3/25/2014 | 3/25/2014 | 3/25/2014 11:46:37 AM | A | DONE |
|
|
need to discuss manual j Phone #: ###-#### >> Inspection requested via web by Brad Allison. Manual J needed on new system serving the upstairs.
|
MEC14-01048
| Final | 3/24/2014 | 3/25/2014 | 3/25/2014 11:22:47 AM | A | PASS |
|
|
This is an AM inspection, please call homeowner prior to inspection at ###-#### Brandi. Phone #: ###-#### >> Inspection requested via web by Mary LaFayette
|
MEC13-05249
| Final | 3/24/2014 | 3/25/2014 | 3/25/2014 11:07:19 AM | A | PASS |
|
|
Jason w/TML Phone #: ###-#### >> Inspection requested via web by Michele LaMott
|
MEC14-01025
| Rough-in | 3/24/2014 | 3/25/2014 | 3/25/2014 10:12:28 AM | A | PART |
|
|
Phone #: ###-#### >> Inspection requested via web by claude croy - 20LB gas pressure pass, 5Lb flue pressure pass. Need 6" fresh air duct to return per manual J.
|
MEC14-01105
| Rough-in | 3/24/2014 | 3/25/2014 | 3/25/2014 8:02:39 AM | A | CANC |
|
|
Rough In and Pressure Test please.
Contact: Adam ###-#### Phone #: ###-#### >> Inspection requested via web by Frank Marturello Inspection cancelled from web by: Frank Marturello
|