Inspections for the day of: Wednesday, March 25, 2020.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC20-01078 Rough-in3/24/20203/25/20203/25/2020 3:07:25 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
MEC20-01078 Pressure Test3/25/20203/25/20203/25/2020 3:07:10 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves- 5lb flue pass- 20lb gas pass
MEC20-01242 Final3/25/20203/25/20203/25/2020 2:45:42 PMPPASS
We need latest appointment possible, please call when in route Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace a/c coil co locking caps ok
MEC20-00994 Final3/25/20203/25/20203/25/2020 2:25:51 PMPPASS
jim - please inspect asap ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- final ok
MEC20-00994 Rough-in3/25/20203/25/20203/25/2020 2:25:28 PMPPASS
jim - please inspect asap ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- R/I ok
MEC20-01250 Final3/25/20203/25/20203/25/2020 1:57:04 PMPPASS
Please call contractor prior to inspection @ ###-####. Ted will be waiting for you. Home owner has cancer and we are trying to take extra precautions. Thank you Inspection requested via web by Margie Rowe- furnace a/c coil co locking caps ok
MEC19-05241 Rough-in3/25/20203/25/20203/25/2020 1:18:17 PMPPASS
Cover Inspection for 2nd Floor
Please contact Jesse at ###-#### prior to arrival Phone #: ###-#### Inspection requested via web by Commercial Coordinator- ceiling cover all areas 2nd floor ok- ok for ceiling tiles- need 1st floor cover inspection called in when ready
MEC20-01210 Rough-in3/25/20203/25/20203/25/2020 12:47:00 PMPFAIL
Phone #: ###-#### Inspection requested via web by JOSE DUARTE
1- needs transfers installed all bedrooms
2- oval duct in laundry room wall needs extended up higher into attic
3- bedroom 3 needs supply wye branch insulated and tap needs sealed and insulated
4- remove spray foam around b vent 2nd floor at attic
5- need to insulate supply wye branch above mater bath bare metal showing

left notice front window
MEC20-01210 Pressure Test3/25/20203/25/20203/25/2020 12:42:42 PMPPASS
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- 20lb gas pass tagged meter location
MEC19-05815 Rough-in3/24/20203/25/20203/25/2020 10:52:50 AMAPASS
rough in for cover. please call shawn prior to arrival for access Phone #: ###-#### Inspection requested via web by Nicholas Paige- R/I on flex registers and insulation all areas ok- ok for ceiling tiles
MEC20-01110 Rough-in3/24/20203/25/20203/25/2020 9:33:04 AMAPASS
Phone #: ###-#### Inspection requested via web by Lindsey Stegemann- fireplace R/I ok
MEC20-01218 Rough-in3/24/20203/25/20203/25/2020 9:15:03 AMAPASS
Phone #: ###-#### Inspection requested via web by Lindsey Stegemann- Fireplace R/I ok
MEC18-05886 Mec-Aging Inspection3/25/20203/25/20203/25/2020 8:50:12 AM FAIL
needs called in for final inspection or request extension on this permit- permit will expire next aging if no activity
MEC17-05182 Mec-Aging Inspection3/25/20203/25/20203/25/2020 8:47:17 AM CANC
WIP- homeowner needs to request extension or call in for final
MEC19-00734 Mec-Aging Inspection3/25/20203/25/20203/25/2020 8:46:37 AM CANC
permit expired
MEC19-00734 DOC - Permit Expired3/25/20203/25/20203/25/2020 8:46:26 AMAPASS
no calls no activity- permit expired
MEC19-03888 Mec-Aging Inspection3/25/20203/25/20203/25/2020 8:45:50 AM CANC
MEC19-03888 Final3/25/20203/25/20203/25/2020 8:45:40 AMAPASS
should have finaled out at pressure test inspection