Inspections for the day of: Thursday, March 26, 2009.
Number of inspections: 7
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTony Young
TitleBLD-COM/RES INSPECTOR
Phone #794-9462
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD08-02542 Extend Permit 180 days3/26/20093/26/20093/26/2009 4:42:14 PMPPASS
wip,, ok
BLD09-00336 BLD-Conference3/26/20093/26/20093/26/2009 3:09:22 PMPPASS
Jack Phone #: ###-####
ok to make new stairs in existing area that is 33" on lower,, 36" above,, no trim or handrail
BLD09-00187 BLD-Energy code compliance3/26/20093/26/20093/26/2009 2:07:59 PMPPASS
Dean- call 20 mins prior to going for access Phone #: ###-####
BLD09-00187 BLD-Energy code compliance3/25/20093/26/20093/26/2009 12:08:59 PMAPASS
Dean- call 20 mins prior to going for access Phone #: ###-####
BLD06-00061 BLD-Final3/25/20093/26/20093/26/2009 11:36:10 AMAFAIL
Read your email for the garage I farwarded to you on 3-25-09 in the afternoon
c/n posted,, 9 items,, c/n in kitchen,, need: sprinklers finaled,, fire caulk holes in garage,, verify elec permit covered whole house and not just 3 rooms per permit scope,, cut curb for driveway or justify with a letter of ok from ACHD,, make smoke detectors functional for testing,, install missing ponywall studs under floor,, clean debris out of crawl space,, seal exterior crawl vents where pipes go through,, Do we have the City reviewed plans?
ESC08-00851 Site Final3/25/20093/26/20093/26/2009 10:09:45 AMAPASS
ESC08-00851 DOC - Permit Finaled3/26/20093/26/20093/26/2009 10:09:19 AMPPASS