Inspections for the day of: Monday, March 26, 2018.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-03479 Conference3/23/20183/26/20183/26/2018 3:18:12 PMPPASS
James Phone #: ###-####
Had verbal over phone with 363 and discussed adding 1 exterior light and 1 exterior receptacle
ELE17-03479 Final3/26/20183/26/20183/26/2018 3:16:59 PMPPASS
James Phone #: ###-####
Final ok
ELE17-03479 Electrical Rough-In3/26/20183/26/20183/26/2018 3:16:36 PMPPASS
James Phone #: ###-####
1 exterior light and 1 receptacle Rough in ok
ELE18-00577 Final3/26/20183/26/20183/26/2018 3:04:46 PMPPASS
Lockbox is on riser room door, outside north entrance. The code is 2677. Suite 225 Phone #: ###-#### Inspection requested via web by Dean Gernaat Final ok
ELE17-03230 Electrical Rough-In3/26/20183/26/20183/26/2018 2:28:57 PMPPASS
Sign is being installed today Phone #: ###-#### Inspection requested via web by Steve VanWinkle
2 wall signs only, spoke with contractor and monument sign not included in work order at this time. He check into this sign listed on permit a schedule accordingly. '
Listing and disonnecting means confirmed on wall signs only. Rough in ok
ELE18-00995 Permanent Service3/22/20183/26/20183/26/2018 2:01:45 PMPPASS
Contact: Jason Noble Phone #: ###-#### Inspection requested via web by Deb Gooden
110.26(A)- A minimum of 30" wide and 36" deep shall be provided for work space.
Spoke to home owner about work space for interior panel. p/s u/g rec ok
ELE18-00952 Final3/22/20183/26/20183/26/2018 1:16:06 PMPPASS
Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg Final ok
ELE17-03881 Final3/25/20183/26/20183/26/2018 10:17:09 AMAPASS
garage code 1905 Phone #: ###-#### Inspection requested via web by kevin blackmon Final ok
ELE18-01081 Rough-In Permanent Service3/22/20183/26/20183/26/2018 9:50:01 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk
Rough in ok cover p/s u/g n ok
ELE18-00810 Permanent Service3/23/20183/26/20183/26/2018 9:00:03 AMAPASS
We have installed the permanent service by passing setting a temporary pole please call me. We have put a temporary protection cover over it as the roof is being installed this week Phone #: ###-#### Inspection requested via web by Brad Baker
250.8- Connection to building steel shall be made with a machine screw not self tapping button head screw. Ufer in place.
408.3(A)(2)- Service termination lugs shall have barriers installed to prevent accidental contact. Contractor to complete 3/26.
Easy corrections. p/s o/h n ok
ELE18-01109 Rough-In Permanent Service3/26/20183/26/20183/26/2018 7:31:30 AMPCANC
Phone #: ###-#### >> Inspection requested via web by cal crosby Inspection cancelled from web by: cal crosby