BLD05-02759
| BLD-Energy code compliance | 3/27/2006 | 3/27/2006 | 3/27/2006 4:36:28 PM | P | PART |
|
|
doug; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD05-02758
| BLD-Energy code compliance | 3/24/2006 | 3/27/2006 | 3/27/2006 4:36:10 PM | P | PART |
|
|
doug; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD05-01422
| BLD-Framing/Rough-in | 3/27/2006 | 3/27/2006 | 3/27/2006 3:31:42 PM | P | FAIL |
|
|
anthony ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie. Still needs to remove non rated box froim 1 hr wall, Add strap to bearing wall at duct penetration upstairs in bathroom. 5/8 type X required behind shower stall. All other framing issues have been repaired as per new approved detail per G. Slane. ok to insulate. c/n posted.
|
BLD05-02410
| BLD-Wall cover | 3/27/2006 | 3/27/2006 | 3/27/2006 3:01:07 PM | P | PART |
|
|
shear inspection ready to side Internet Inspection Request from: paul thornton. Shear nail on exterior walls.
|
BLD05-02411
| BLD-Wall cover | 3/27/2006 | 3/27/2006 | 3/27/2006 3:00:34 PM | P | PART |
|
|
shear inspection ready to side Internet Inspection Request from: paul thornton. Shear nail insp. on exterior walls.
|
BLD05-02120
| BLD-Framing/Rough-in | 3/27/2006 | 3/27/2006 | 3/27/2006 2:07:46 PM | P | PASS |
|
|
Scott; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. All framing issues have been resolved.
|
BLD05-02120
| BLD-Energy code compliance | 3/27/2006 | 3/27/2006 | 3/27/2006 2:07:11 PM | P | PASS |
|
|
Scott; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
|
BLD05-01261
| BLD-Conference | 3/27/2006 | 3/27/2006 | 3/27/2006 11:51:22 AM | A | DONE |
|
|
Due to phone call from a concerned citizen, on site to view damage of steel stud wall and roofing due to severe storms. majority of steel stud wall has been removed. Contractor has scheduled his structural engineer for site observation.
|
BLD05-00235
| BLD-Final | 3/24/2006 | 3/27/2006 | 3/27/2006 11:46:01 AM | A | NR |
|
|
bob; Phone #: ###-#### please call 1/2 hr prior Internet Inspection Request from: Cathy Chiles. Spoke to contractor on phone. Noted to Bob that the mech. permit had not been finaled due to issue with dryer vent and that the mech. permit had been expired. Contractor noted that he would correct mech issues and sall back for bldg. final.
|
BLD02-02171
| BLD-Aging Inspection | 3/27/2006 | 3/27/2006 | 3/27/2006 10:47:27 AM | | CANC |
|
|
|
BLD02-02171
| DOC - Permit Expired | 3/27/2006 | 3/27/2006 | 3/27/2006 10:47:11 AM | A | DONE |
|
|
Work appears to be complete.
|
BLD05-02923
| BLD-Concrete | 3/23/2006 | 3/27/2006 | 3/27/2006 10:18:55 AM | A | PASS |
|
|
john; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa. Column pad footings.
|
BLD05-02404
| BLD-Footing | 3/26/2006 | 3/27/2006 | 3/27/2006 9:58:10 AM | A | PASS |
|
|
interior footing and rebar lookie Internet Inspection Request from: paul thornton
|
BLD05-01611
| BLD-Framing/Rough-in | 3/24/2006 | 3/27/2006 | 3/27/2006 8:55:24 AM | A | NR |
|
|
Max -- call 1st before insp; prefer 8AM; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. No plans or truss engineering on site. Contractor to reschedule framing insp. for pm.
|
BLD02-01970
| BLD-Aging Inspection | 3/27/2006 | 3/27/2006 | 3/27/2006 8:23:15 AM | | CANC |
|
|
|
BLD02-01970
| DOC - Permit Finaled | 3/27/2006 | 3/27/2006 | 3/27/2006 8:23:04 AM | A | DONE |
|
|
All inspections were done and passed by others as per history.
|