Inspections for the day of: Tuesday, March 27, 2012.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-01576 ELE-Aging Inspection3/27/20123/27/20124/3/2012 9:31:26 AM DONE
see final
ELE11-01548 ELE-Aging Inspection3/27/20123/27/20124/3/2012 8:39:55 AM DONE
see final
ELE11-01514 ELE-Aging Inspection3/27/20123/27/20123/29/2012 2:57:32 PM DONE
still under construction
ELE12-00384 Final3/27/20123/27/20123/28/2012 2:05:30 PMPPASS
jeff Phone #: ###-#### BOB ypu will need to call for access ok final
ELE12-00385 Electrical Rough-In3/27/20123/27/20123/28/2012 12:27:24 PMPPASS
jeff BOB you will need to call for access Phone #: ###-#### ri ok
ELE12-00622 Electrical Rough-In3/27/20123/27/20123/27/2012 4:01:04 PMPPASS
Mike Phone #: ###-#### ri ok
ELE12-00458 Final3/26/20123/27/20123/27/2012 2:48:46 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin ok final, signed card
ELE12-00613 Final3/27/20123/27/20123/27/2012 1:51:19 PMPPASS
Roger Phone #: ###-#### ok final
ELE12-00572 Electrical Rough-In3/27/20123/27/20123/27/2012 1:07:44 PMPPASS
Uffer ground inspection Phone #: ###-#### >> Inspection requested via web by Bryan Atkins concrete encased electrode only ok to pour
ELE12-00617 Permanent Service3/27/20123/27/20123/27/2012 12:23:25 PMPPASS
MOBILE HOME # 26, NEEDS SERVICE INSPECTION FOR PERMANENT POWER Phone #: ###-#### >> Inspection requested via web by JENNY EMEL p/s u/g rec ok
ELE12-00587 Final3/26/20123/27/20123/27/2012 10:26:42 AMAPASS
Homeowner will be home. Phone #: ###-#### >> Inspection requested via web by Craig Korell ok final
ELE12-00540 Final3/22/20123/27/20123/27/2012 10:10:39 AMAPASS
Phone #: ###-#### >> Inspection requested via web by David McClellan ok final
ELE12-00618 Rough-In Permanent Service3/26/20123/27/20123/27/2012 9:46:59 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson called, left message, left correction notice, BCC shall not cover u/g without inspection, framing shall be complete, wiring shall be installed, shall provide available fault current from IPCO at service, NEC 334.23 shall protect cables within 6' of attic access, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing member or provide nail plates
ELE12-00613 Permanent Service3/26/20123/27/20123/27/2012 9:00:29 AMAPASS
Roger Goodman Phone #: ###-#### p/s o/h rec ok
ELE12-00456 Electrical Rough-In3/26/20123/27/20123/27/2012 8:35:59 AMAPASS
can lights in soffit, Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin soffit only ok cover
ELE12-00614 Electrical Rough-In3/26/20123/27/20123/27/2012 7:55:42 AMAPASS
soffit and walls Phone #: ###-#### >> Inspection requested via web by Bryan McLaughlin walls and soffits ok cover