ELE12-02402
| Final | 3/27/2013 | 3/27/2013 | 3/27/2013 2:19:10 PM | P | NH |
|
|
Please call Bill if you have any questions. Phone #: ###-#### >> Inspection requested via web by Rhonda Yoast no access due to painting exterior of house
|
ELE12-03031
| Final | 3/27/2013 | 3/27/2013 | 3/27/2013 1:48:37 PM | P | NH |
|
|
Phone #: ###-#### >> Inspection requested via web by Mark M unable to make contact to perform inspection
|
ELE12-02130
| Final | 3/27/2013 | 3/27/2013 | 3/27/2013 1:25:17 PM | P | PASS |
|
|
Pease call Bill if you have any questions. Phone #: ###-#### >> Inspection requested via web by Rhonda Yoast trench final ok
|
ELE12-02751
| Final | 3/27/2013 | 3/27/2013 | 3/27/2013 1:22:03 PM | P | FAIL |
|
|
Please call Bill if you have any questions Phone #: ###-#### >> Inspection requested via web by Rhonda Yoast 210.8 (A)(6)- Appliance garage- Where recepticals are installed to serve counter top surfaces they shall have GFCI protection. 110.7- Complete wiring installation- bed arcfault breaker will not hold. 110.22 Each disconnecting means shall be marked to indicate its purpose. Due to HVAC code residential garages from floor to 18" above floor shall be considered class 1 division 1 due to fuel storage and lack of air movement. Recepticals shall be installed above 18" from floor
|
GCE13-00045
| GCE-Courtesy | 3/27/2013 | 3/27/2013 | 3/27/2013 12:11:44 PM | P | DONE |
|
|
amy - ###-#### Discussed overhead roof clearences, interior electrical room egress illumination and panic hardware.
|
ESC12-01129
| General Inspection | 3/27/2013 | 3/27/2013 | 3/27/2013 10:24:51 AM | | PASS |
|
|
|
ELE13-00695
| Conference | 3/26/2013 | 3/27/2013 | 3/27/2013 10:02:50 AM | A | DONE |
|
|
john - call 15 mins prior for access Phone #: ###-#### Discussed master bed and bath remodel code required outlets for bed and bath, smoke detectors, NM cable supports on stud members
|
ELE13-00337
| Final | 3/26/2013 | 3/27/2013 | 3/27/2013 9:17:45 AM | A | FAIL |
|
|
kenny or todd Phone #: ###-#### As per installation instructions additional GFCI protection required for floor heat. Conduit on back deck to disconnect shall be strapped.
|
ELE13-00676
| Final | 3/26/2013 | 3/27/2013 | 3/27/2013 8:46:32 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by sam petterson Final ok
|
ELE13-00688
| Final | 3/26/2013 | 3/27/2013 | 3/27/2013 8:38:53 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by sam petterson Final ok
|
ELE11-02806
| Rough-In Permanent Service | 3/26/2013 | 3/27/2013 | 3/26/2013 2:59:19 PM | A | PASS |
|
|
3rd floor rough in walls call mike 1/2 prior Phone #: ###-#### >> Inspection requested via web by Shawna Gates New tenant space wall rough in ok cover
|
ELE11-02806
| Electrical Rough-In | 3/26/2013 | 3/27/2013 | 3/26/2013 11:55:28 AM | P | CANC |
|
|
3rd floor atrium wall rough in...call mike 1/2 prior Phone #: ###-#### >> Inspection requested via web by Shawna Gates Inspection cancelled from web by: Shawna Gates
|