ELE11-02886
| ELE-Aging Inspection | 3/27/2015 | 3/27/2015 | 3/27/2015 1:59:40 PM | | DONE |
|
|
still under construction
|
ELE15-00223
| Final | 3/27/2015 | 3/27/2015 | 3/27/2015 1:58:16 PM | P | NR |
|
|
Key in front outlet Phone #: ###-#### Inspection requested via web by TOM BICANDI sign on door for wet floors, called contractor to recall
|
ELE14-02373
| Electrical Rough-In | 3/26/2015 | 3/27/2015 | 3/27/2015 1:55:58 PM | P | PASS |
|
|
Site under ground inspection for 4 each pole bases and conduit in front of HL and retaining wall south east corner of G. Building permit number BLD13-02064. Call Lonny when on site. Thanks. Phone #: ###-#### Inspection requested via web by Lonny Baum ok cover as requested
|
ELE14-02067
| Electrical Rough-In | 3/26/2015 | 3/27/2015 | 3/27/2015 1:21:30 PM | P | PASS |
|
|
Rough-in inspection SNF L Electrical room L125 walls only for sheet rock and gear install. Building permit number BLD13-00191. Call Lonny when on site. Thanks. Phone #: ###-#### Inspection requested via web by Lonny Baum ok cover as requested
|
ELE15-00816
| Temporary Service | 3/27/2015 | 3/27/2015 | 3/27/2015 11:34:04 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Burke t/s u/g n ok
|
ELE14-03163
| Final | 3/27/2015 | 3/27/2015 | 3/27/2015 11:15:59 AM | P | FAIL |
|
|
Keith-if locked call Keith for access Phone #: ###-#### called, left correction notice, BCC shall change room count from 1 to 10 rooms on permit, NEC 110.26(E) there shall be no foreign systems in dedicated panel space i.e. ducts or piping, 334.30 shall securely support nm cable within 12" of panel, 300.4 shall provide cable protection if over 1/14" to edge of hole or cable
|
ELE14-03399
| Final | 3/26/2015 | 3/27/2015 | 3/27/2015 10:40:32 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jay Symonds ok final
|
ELE15-00773
| Temporary Service | 3/26/2015 | 3/27/2015 | 3/27/2015 9:56:21 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE15-00771
| Temporary Service | 3/26/2015 | 3/27/2015 | 3/27/2015 9:34:04 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE15-00775
| Rough-In Permanent Service | 3/24/2015 | 3/27/2015 | 3/27/2015 8:58:41 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk ri ok, p/s u/g n ok
|
ELE14-03219
| Electrical Rough-In | 3/26/2015 | 3/27/2015 | 3/27/2015 7:56:08 AM | A | PASS |
|
|
Ceiling inspect for the Telecom room. Contact is Justin Bieker. Phone #: ###-#### Inspection requested via web by Richard Montgomery ok cover ceiling as requested
|