MEC17-01031
| Final | 3/23/2017 | 3/27/2017 | 3/27/2017 3:41:17 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
MEC17-00882
| Rough-in | 3/24/2017 | 3/27/2017 | 3/27/2017 2:38:41 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Lisa Whitney need flex bedroom 2
|
MEC17-00882
| Pressure Test | 3/24/2017 | 3/27/2017 | 3/27/2017 2:38:05 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Lisa Whitney test at zero
|
MEC17-01083
| Final | 3/27/2017 | 3/27/2017 | 3/27/2017 1:47:25 PM | P | PASS |
|
|
please call Rod, Thank YOUI! Phone #: ###-#### Inspection requested via web by Rhonda Marcum
|
MEC17-00940
| Rough-in | 3/27/2017 | 3/27/2017 | 3/27/2017 1:47:09 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Jon VanderStelt fresh air not done, pex still touching bvent 1st floor
|
MEC17-00940
| Pressure Test | 3/27/2017 | 3/27/2017 | 3/27/2017 1:46:19 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Jon VanderStelt gage at zero, need to fix flash shield connection by gage
|
MEC17-00776
| Rough-in | 3/27/2017 | 3/27/2017 | 3/27/2017 1:23:34 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer
|
MEC17-00776
| Pressure Test | 3/27/2017 | 3/27/2017 | 3/27/2017 1:23:11 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer 60lb, 20lb x2 gas test okay needs flue pressure test on water heater in master bath
|
MEC16-02295
| Final | 3/24/2017 | 3/27/2017 | 3/27/2017 10:12:44 AM | A | PASS |
|
|
Onsite contact: Trever Jensen Phone #: ###-#### Inspection requested via web by Melissa Kaae
|
MEC17-01093
| Rough-in | 3/26/2017 | 3/27/2017 | 3/27/2017 10:03:45 AM | A | PASS |
|
|
20# and 5# and f/pok
|
MEC17-00776
| Pressure Test | 3/22/2017 | 3/27/2017 | 3/27/2017 9:24:35 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer below 20lb
|
MEC17-00776
| Rough-in | 3/22/2017 | 3/27/2017 | 3/27/2017 9:24:06 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer
|
MEC16-03858
| Mec-Aging Inspection | 3/27/2017 | 3/27/2017 | 3/27/2017 9:12:17 AM | | PEND |
|
|
bld still issued
|
MEC17-00930
| Rough-in | 3/26/2017 | 3/27/2017 | 3/27/2017 9:10:57 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves
|
MEC17-00930
| Pressure Test | 3/26/2017 | 3/27/2017 | 3/27/2017 9:10:40 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves 20lb gas
|
MEC17-00500
| Final | 3/24/2017 | 3/27/2017 | 3/27/2017 8:53:12 AM | A | PASS |
|
|
Would like 8-10 and call when on way. Thank you! Phone #: ###-#### Inspection requested via web by Xanti Berria
|