ELE13-01291
| Final | 3/26/2018 | 3/27/2018 | 3/27/2018 3:16:04 PM | P | PASS |
|
|
Please contact John Mittleider for questions regarding inspection details. Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Final ok
|
ELE18-00491
| Electrical Rough-In | 3/27/2018 | 3/27/2018 | 3/27/2018 1:32:28 PM | P | FAIL |
|
|
Ceiling Cover. Danny is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen 300.11- Luminaires shall be supported independant of ceiling support system unless manufacturers instructions state ceilling system can handle additional weight. 300.15- All wiring shall terminate in a box and shall be accessible. Conduit with wiring in it, Old disconnect and buried box on perimeter wall.
|
ELE18-01120
| Electrical Rough-In | 3/26/2018 | 3/27/2018 | 3/27/2018 12:38:14 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Terry Scott Main level kitchen, powder, mudroom and basement rough in ok cover
|
ELE17-01337
| Electrical Rough-In | 3/26/2018 | 3/27/2018 | 3/27/2018 10:21:54 AM | A | PASS |
|
|
We are requesting a rough-in inspection for the hallways and ceilings on floors 2, 3, 4, and 5 for tomorrow morning. Our contact is Rick @ ###-####. Thank you Phone #: ###-#### Inspection requested via web by Larry Looney Cable tray bonds complete drop hardlids noted rough in ok cover
|
ELE17-03230
| Final | 3/26/2018 | 3/27/2018 | 3/27/2018 9:19:22 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Steve VanWinkle Spoke with contact 3-26-18 and he stated inspection would be cancelled if monument sign is still part of scope of work. As of 3-26-18 monument sign not part of work order. 2 wall signs only final ok
|
ELE17-02167
| Final | 3/26/2018 | 3/27/2018 | 3/27/2018 9:14:08 AM | A | PASS |
|
|
UL are on top and start with J 17769087. Disconnect is on power supply can. Phone #: ###-#### Inspection requested via web by Steve VanWinkle Final ok
|
ELE17-02167
| Electrical Rough-In | 3/27/2018 | 3/27/2018 | 3/27/2018 9:13:47 AM | P | PASS |
|
|
UL are on top and start with J 17769087. Disconnect is on power supply can. Phone #: ###-#### Inspection requested via web by Steve VanWinkle Listing confirmed rough in ok
|
ELE17-01349
| Final | 3/26/2018 | 3/27/2018 | 3/27/2018 9:13:09 AM | A | PASS |
|
|
UL is on the left hand side as u face it. Phone #: ###-#### Inspection requested via web by Steve VanWinkle Final ok
|
ELE17-01349
| Electrical Rough-In | 3/27/2018 | 3/27/2018 | 3/27/2018 9:12:37 AM | P | PASS |
|
|
UL is on the left hand side as u face it. Phone #: ###-#### Inspection requested via web by Steve VanWinkle Listing confirmed rough in ok
|
ELE18-01015
| Rough-In Permanent Service | 3/26/2018 | 3/27/2018 | 3/27/2018 8:47:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|