Inspections for the day of: Friday, March 27, 2020.
Number of inspections: 31
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTell Riley
TitleBLD-COM/RES INSPECTOR
Phone #830-2752
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD20-00399 BLD-Footing3/27/20203/27/20203/27/2020 4:42:44 PMPPART
Phone #: ###-#### Inspection requested via web by Shane Shade
BLD20-00398 BLD-Footing3/27/20203/27/20203/27/2020 4:42:34 PMPPART
Phone #: ###-#### Inspection requested via web by Shane Shade
BLD20-00397 BLD-Footing3/27/20203/27/20203/27/2020 4:42:20 PMPPART
Phone #: ###-#### Inspection requested via web by Shane Shade
BLD20-00357 BLD-Footing3/27/20203/27/20203/27/2020 4:42:06 PMPPART
Phone #: ###-#### Inspection requested via web by Shane Shade
BLD19-03460 BLD-Wall Bracing3/27/20203/27/20203/27/2020 4:41:53 PMPPART
Jorge Phone #: ###-####//need to add hot dip galvanized nails to pt//add blocking///add straps on 2nd story//
BLD20-00527 BLD-Footing3/27/20203/27/20203/27/2020 4:01:47 PMPPART
call owner ###-####//zoning document shows approved for 2'6" side setback and 12 front//appears to be 3' check when posts are installed/vertical construction begins//may need to rate soffits, nothing on plans for rated soffits, posts//footing depth ok//
BLD20-00775 BLD-Footing3/27/20203/27/20203/27/2020 3:22:06 PMPPART
WIP//per plans on rebar//
BLD20-00474 BLD-Foundation3/27/20203/27/20203/27/2020 3:00:54 PMPPART
Greg Phone #: ###-####//WIP//
BLD20-00474 BLD-Footing3/27/20203/27/20203/27/2020 3:00:35 PMPPART
Call to be let in // Greg Phone #: ###-####//WIP//
BLD20-00633 BLD-Framing/Rough-in3/27/20203/27/20203/27/2020 2:44:46 PMPNR
ben Phone #: ###-####//not ready//will need to call back in when ready//
BLD19-04094 BLD-Wall Bracing3/25/20203/27/20203/27/2020 2:18:39 PMPFAIL
Dan Phone #: ###-#### Inspection requested via web by Daniel Appel//need to add hot dip galvanized nails at PT//nails shear panels marked in red//finish shear panels//add blocks where noted//told him to call back in//
BLD20-00137 BLD-Framing/Rough-in3/27/20203/27/20203/27/2020 1:33:53 PMPPASS
Inspection requested via web by James Jackson//ok, need to fix joist above garage, nail girder//ok to insulate//
BLD19-02407 BLD-Energy code compliance3/27/20203/27/20203/27/2020 1:07:07 PMPPART
Inspection requested via web by James Jackson//window U values at .34, discussed with Dennis, will run RES CHeck for trade offs to meet code//insulate above FP///
BLD19-03229 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 12:40:11 PMANR
Phone #: ###-#### Inspection requested via web by Carl Funk//used as conference with engineer of record and contractor//some engineering will need to be completed and corrections made in framing//need I joist manual for plumbing in Is//need truss engineering//
BLD19-03253 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 12:39:57 PMANR
Phone #: ###-#### Inspection requested via web by Carl Funk//used as conference with engineer of record and contractor//some engineering will need to be completed and corrections made in framing//need I joist manual for plumbing in Is//need truss engineering//
BLD19-03247 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 12:39:43 PMANR
Phone #: ###-#### Inspection requested via web by Carl Funk//used as conference with engineer of record and contractor//some engineering will need to be completed and corrections made in framing//need I joist manual for plumbing in Is//need truss engineering//
BLD19-03248 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 12:39:28 PMANR
Phone #: ###-#### Inspection requested via web by Carl Funk//used as conference with engineer of record and contractor//some engineering will need to be completed and corrections made in framing//need I joist manual for plumbing in Is//need truss engineering//
BLD19-03249 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 12:39:12 PMANR
Phone #: ###-#### Inspection requested via web by Carl Funk//used as conference with engineer of record and contractor//some engineering will need to be completed and corrections made in framing//need I joist manual for plumbing in Is//need truss engineering//
BLD19-03250 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 12:38:56 PMANR
Phone #: ###-#### Inspection requested via web by Carl Funk//used as conference with engineer of record and contractor//some engineering will need to be completed and corrections made in framing//need I joist manual for plumbing in Is//need truss engineering//
BLD19-03251 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 12:38:39 PMANR
Phone #: ###-#### Inspection requested via web by Carl Funk//used as conference with engineer of record and contractor//some engineering will need to be completed and corrections made in framing//need I joist manual for plumbing in Is//need truss engineering//
BLD19-03252 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 12:38:17 PMANR
Phone #: ###-#### Inspection requested via web by Carl Funk//used as conference with engineer of record and contractor//some engineering will need to be completed and corrections made in framing//need I joist manual for plumbing in Is//need truss engineering//
MIS19-00155 MIS-Aging Inspection3/27/20203/27/20203/27/2020 10:42:22 AM PEND
BLD19-00974 DOC - Permit Expired2/14/20203/27/20203/27/2020 10:41:51 AMPDONE
expired//
BLD18-04123 BLD-Aging Inspection3/27/20203/27/20203/27/2020 10:41:12 AM PEND
Expires: 05/12/20
MIS18-00110 MIS-Aging Inspection3/27/20203/27/20203/27/2020 10:40:08 AM PEND
permit shows issued status, appears to still be under review based on plan reveiwers activity//have had no contact with owner or contractor on the project//
BLD19-00534 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 10:31:05 AMAPEND
Shaftliner cover and 4th floor ok to insulate Phone #: ###-#### Inspection requested via web by Travis Blackburn//ok when firecaulk has been done at shaftliner//ok to insualate 4th floor pending other trades inspections//
BLD19-00535 BLD-Framing/Rough-in3/26/20203/27/20203/27/2020 10:27:24 AMAPART
Framing inspection at breezeway ceiling to install shaftliner assembly to bottom of trusses Phone #: ###-#### Inspection requested via web by Travis Blackburn//ok when H2.5s are installed//
BLD19-04743 BLD-Energy code compliance3/25/20203/27/20203/27/2020 10:26:50 AMAPASS
Phone #: ###-#### Inspection requested via web by Peter Harris
BLD19-04296 BLD-Final3/26/20203/27/20203/27/2020 9:26:10 AMAFAIL
willie Phone #: ###-####//Correction notice posted//caulk penetrations at garage wall//remove dust covers from smoke/co detectors//add fall prevention/opening limitaiton devices at windows with sill height less than 24"//post insulation certificate//
BLD20-00385 BLD-Other3/26/20203/27/20203/27/2020 8:40:19 AMANR
New Roof - not including decks, which owner plans to convert to pergola structures this summer. Also new siding.

Please let us know if we should be using a different ''Inspection Type.'' Thank you! Stay Well!! Phone #: ###-#### Inspection requested via web by Gerald Summers/roofing does not appear to be completed/new//please call when new roof has been installed//
BLD19-03701 BLD-Conference3/26/20203/27/20203/27/2020 8:22:29 AMADONE
adam Phone #: ###-####//discussed via phone, front door will be required to be main egress, one step allowed to landing, landing must be 36" in direction of travel and as wide as door//also sent photo of code sections for required egress and landing//