PDS Online
Making
Boise
the most livable city in the country.
Home
Permits
Search by Permit Number
How to search by permit number
Search by Address
Search by Customer Number
Search by Current Planning Number
Search in Project by Permit Number
Search by Project Name
Inspections
Search by Permit Number
Search by Request Date
Search by Company Name
Fees
Impact Fees Estimate Calculator
Other Searches
Search for Licensed Contractors
Search Parcel by Address
Search Historical Surveys
Reports
Daily Reports
Weekly Reports
Monthly Reports
Home
/
Inspections
/
Inspector Activity
Inspections for the day of:
Tuesday, March 28, 2006
.
Number of inspections:
12
Percentage of inspections complete:
100 %
Percentage of inspections not complete:
0 %
Contact Information
Inspector
Mike Jordan
Title
BLD-COM/RES INSPECTOR
Phone #
794-9473
Permit Number
Description
Received
Requested
Completed
AM/PM
Disposition
BLD05-00001
BLD-Wall cover
3/28/2006
3/28/2006
3/28/2006 4:38:42 PM
P
PASS
Scheduled by a contractor via Hello! on 3/28/2006 at 7:18:37 AM. Contact: ###-####.
BLD05-00001
BLD-Energy code compliance
3/28/2006
3/28/2006
3/28/2006 4:38:27 PM
P
PASS
Scheduled by a contractor via Hello! on 3/28/2006 at 7:17:13 AM. Contact: ###-####.
MIS06-00068
BLD-Conference
3/28/2006
3/28/2006
3/28/2006 4:10:23 PM
P
DONE
Complaint of shifting/settling foundation. Susan @ ###-####. Arrived on site to evaluate complaint of settling foundation. Notd that house was a two story house. Did observe cracks in foundation at lower level, and noted hat backyard slab had settled significatlly. Also noted that one window would not close properly due to oening being ut of square. Did not observe any cracks on interior sheet rock. Home owners are planng a remodel, but were concerned about settling. Noted to homeowners to contact a structural enineer to observe the cracking. Also noted that more investegation may be needed by a geo-tech organazation. Noted to homeowners that I coul not tell for sure if foundation was settling and that further investagation would be needed.
BLD05-02489
BLD-Framing/Rough-in
3/27/2006
3/28/2006
3/28/2006 3:01:19 PM
P
PART
Jack -- roof nail inspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong. Roof insp. All missing hardware gas been installed. ok to cover roof. Contractor to supply RFI regarding placement of some straps.
BLD05-02417
BLD-Footing
3/28/2006
3/28/2006
3/28/2006 2:02:31 PM
P
PASS
interior footing and rebar lookie Internet Inspection Request from: paul thornton
BLD05-02912
BLD-Energy code compliance
3/27/2006
3/28/2006
3/28/2006 1:43:08 PM
P
FAIL
Internet Inspection Request from: Carey Allen
Provide fire blocking IN concealled space upstairs were ductwork passes, hrizontally and vertically.
BLD02-02390
BLD-Aging Inspection
3/28/2006
3/28/2006
3/28/2006 11:00:25 AM
CANC
Store was closed at time of arrival for insp.
BLD02-02218
BLD-Aging Inspection
3/28/2006
3/28/2006
3/28/2006 10:26:49 AM
CANC
BLD02-02218
DOC - Permit Finaled
3/28/2006
3/28/2006
3/28/2006 10:26:38 AM
A
DONE
BLD06-00692
BLD-Footing
3/27/2006
3/28/2006
3/28/2006 9:23:29 AM
A
PASS
mherbert pollard; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
BLD02-02363
BLD-Aging Inspection
3/28/2006
3/28/2006
3/28/2006 8:24:19 AM
CANC
BLD02-02363
DOC - Permit Finaled
3/28/2006
3/28/2006
3/28/2006 8:24:08 AM
A
DONE