Inspections for the day of: Wednesday, March 28, 2007.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-03238 Conference3/28/20073/28/20073/28/2007 3:42:49 PMPDONE
David; Phone #: ###-#### Internet Inspection Request from: Stacie Backus talked about afci, ckt extensions, 1 1/4", outside rear light, outlet spacing
ELE07-01008 Electrical Rough-In3/28/20073/28/20073/28/2007 3:06:09 PMPPASS
ed - pls call 30 prior; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ric ok bath only, need to look at tub, since not there, chek new circuits from panel
ELE07-00023 Final3/28/20073/28/20073/28/2007 2:30:56 PMPPART
Scheduled by a contractor via Hello! on 3/28/2007 at 7:53:25 AM. Contact: ###-####. signed t/o card, left corr notice, nec 408.4 circuit directory shall be clear concise and specific as to its purpose, 605.7 multi-wire branch circuits shall be provided with a means to simultaneously disconnect all ungrounded conductors (partitions), 110.12(C) panel hasps shall be repaired, BCC no violations shall be retained, circuits shall operate
ELE07-00824 Electrical Rough-In3/27/20073/28/20073/28/2007 1:31:48 PMPPASS
CEILING RI Phone #: ###-#### ok to cover ceilings only
ELE07-00815 Electrical Rough-In3/28/20073/28/20073/28/2007 1:12:22 PMPFAIL
Jim pls call 30 min prior; Phone #: ###-#### Internet Inspection Request from: Stacie Backus left corr notice,nec 300.14 at least 6" free conductor shall be left from where conductor enters box for splicing, told to call when fixed, downstairs area only for this part
ELE07-00905 Final3/28/20073/28/20073/28/2007 12:43:53 PMPCANC
Scheduled by a contractor via Hello! on 3/28/2007 at 7:12:48 AM. Contact: ###-####. called contr, he did not call in this
ELE07-00937 Final3/28/20073/28/20073/28/2007 12:31:22 PMPPASS
pat; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok to final
ELE06-04665 Electrical Rough-In3/26/20073/28/20073/28/2007 10:18:15 AMAPASS
Boun; Phone #: ###-#### Internet Inspection Request from: Stacie Backus met owner, ric ok, tub ok
ELE07-00588 Electrical Rough-In3/27/20073/28/20073/28/2007 9:41:59 AMAPASS
Scheduled by a contractor via Hello! on 3/27/2007 at 2:04:54 PM. Contact: ###-####. ok to cover ceilings, see cash wrap at final
ELE07-01006 Final3/27/20073/28/20073/28/2007 9:14:43 AMAPASS
Work performed by Aaron White. Phone #: ###-#### ok to final
ELE07-00321 Electrical Rough-In3/27/20073/28/20073/28/2007 9:03:52 AMACANC
ted; Phone #: ###-#### upstairs inspection // Internet Inspection Request from: Victoria Beall see final, part, for time
ELE07-00321 Final3/28/20073/28/20073/28/2007 9:03:17 AMAPART
ted; Phone #: ###-#### upstairs inspection // Internet Inspection Request from: Victoria Beall contr accepting permit ele06-03008 adding rooms to 07 permit, upstairs only ok to final, will call for rest of permit ltr, should close 06 permit when all done
ELE07-00693 Rough-In Permanent Service3/27/20073/28/20073/28/2007 8:32:25 AMAPASS
Joe Phone #: ###-#### called contr, no plans on job, talked about jetted tubs, access, need to check at final, corrections made, ric ok, p/s u/g n ok
ELE06-03534 Final3/27/20073/28/20073/27/2007 4:55:56 PMACANC
Call 1/2 hour before inspection to gain entry into the house. Plese call Chad at the listed number. thank you Phone #: ###-#### Inspection cancelled from web by: Patricia Smith