FIR06-00540
| INSP-Final Inspection | 3/27/2008 | 3/28/2008 | 3/28/2008 3:54:47 PM | A | NR |
|
|
Scheduled by a contractor via Hello! on 3/27/2008 at 3:25:39 PM. Contact: ###-####.
|
BLD07-03251
| FIRE-Final Inspection | 3/27/2008 | 3/28/2008 | 3/28/2008 3:54:05 PM | A | PASS |
|
|
Fire life safety passed.
|
FIR08-00112
| INSP-Final Inspection | 3/28/2008 | 3/28/2008 | 3/28/2008 3:53:13 PM | A | PASS |
|
|
Corrections verified for compliance, mag lock relay programming for three access control doors repaired while on site, permit finaled.
|
BLD07-01878
| FIRE-Final Inspection | 3/28/2008 | 3/28/2008 | 3/28/2008 1:45:29 PM | P | FAIL |
|
|
Final pending project related fire sprinkler permit work, life safety inspection completed okay, good for final when sprinkler modifications are finished.
|
FIR07-00917
| INSP-Final Inspection | 3/28/2008 | 3/28/2008 | 3/28/2008 1:35:43 PM | P | FAIL |
|
|
Discovered a new room added per building plan modification that is missing sprinkler coverage. Remainder of tenant area is acceptable, agreed to allow NFPA 13 2007 edition exception for the small room rule for openings to adjacent spaces less than 3' without a lintel per discussion with S. Rogers. Final pending the addition of one required sprinkler at the new "ETO Room".
|
FIR07-00855
| INSP-Final Inspection | 3/27/2008 | 3/28/2008 | 3/28/2008 1:28:50 PM | A | PASS |
|
|
Fire sprinkler permit work final field inspection passed, noted two missing escutcheons at two restrooms to be installed today, also need to provide QR type heads at the riser head box- these items will be verified for completion at the BLD final.
|
FIR08-00176
| INSP-Final Inspection | 3/27/2008 | 3/28/2008 | 3/28/2008 1:25:53 PM | A | PASS |
|
|
Tenant fire alarm system modifications tested acceptable, permit finaled.
|
FIR07-01045
| FIR-Aging Inspection | 3/28/2008 | 3/28/2008 | 3/28/2008 1:20:28 PM | | DONE |
|
|
Project construction underway, work in progress, not ready for field inspection at this time.
|
BLD08-00043
| FIRE-Final Inspection | 3/27/2008 | 3/28/2008 | 3/28/2008 1:19:18 PM | A | PASS |
|
|
Fire life safety inspection completed acceptable.
|
FIR08-00031
| INSP-Final Inspection | 3/27/2008 | 3/28/2008 | 3/28/2008 1:18:18 PM | A | PASS |
|
|
One defective sprinkler head at an office replaced immediately on site by R. Fry, remainder of fire sprinkler work passed inspection, permit finaled.
|
FIR08-00113
| INSP-Final Inspection | 3/28/2008 | 3/28/2008 | 3/28/2008 10:16:57 AM | P | CANC |
|
|
final Inspection Phone #: ###-#### x1234 Internet Inspection Request from: Alicia Pauley Inspection cancelled from web by: Alicia Pauley
|