ELE12-00194
| ELE-Aging Inspection | 3/28/2018 | 3/28/2018 | 3/29/2018 7:51:22 AM | | DONE |
|
|
Waiting on homeowner.
|
ELE18-01176
| Permanent Service | 3/28/2018 | 3/28/2018 | 3/28/2018 2:00:16 PM | P | PASS |
|
|
Need inspection to cover trench and approve service swing. Phone #: ###-#### Inspection requested via web by Alan Lusk p/s o/h n ok. 100a brkr in meter main needs to be in lowest position of brkr spaces. All other spaces limited to 70a max. Will need to see upon final.
|
ELE18-01090
| Rough-In Permanent Service | 3/28/2018 | 3/28/2018 | 3/28/2018 1:15:43 PM | P | PASS |
|
|
Service change should be ready this afternoon. Please call ahead to confirm. Phone #: ###-#### Inspection requested via web by William Andrews p/s o/h rec ok. Service inspection only, no RI. New 200a meter main mounted up high to accomodate for new deck to be built. 2 grd rods. Existing plumbing changed to poly.
|
ELE18-01178
| Electrical Rough-In | 3/28/2018 | 3/28/2018 | 3/28/2018 12:35:19 PM | P | PASS |
|
|
Garage rough in only and new service on garage. Phone #: ###-#### Inspection requested via web by John Harvey Ok cover garage.
|
ELE18-01119
| Permanent Service | 3/28/2018 | 3/28/2018 | 3/28/2018 11:45:34 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Trevor Soesbe p/s o/h rec ok. Existing water bond there and installed a long with 2 grd rods.
|
ELE18-01178
| Permanent Service | 3/28/2018 | 3/28/2018 | 3/28/2018 11:44:33 AM | P | PASS |
|
|
p/s o/h n ok
|
ELE18-00741
| Electrical Rough-In | 3/28/2018 | 3/28/2018 | 3/28/2018 11:37:06 AM | P | CANC |
|
|
Grid ceiling inspection Phone #: ###-#### >> Inspection requested via web by steve sellers Inspection cancelled from web by: steve sellers
|
ELE18-01166
| Electrical Rough-In | 3/27/2018 | 3/28/2018 | 3/28/2018 10:49:07 AM | A | PASS |
|
|
Master bathroom remodel. Homeowner should be home all day, Phone #: ###-#### Inspection requested via web by Shaun Kirkman Ok cover mstr bath.
|
ELE18-01121
| Rough-In Permanent Service | 3/26/2018 | 3/28/2018 | 3/28/2018 10:14:46 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Emmet Bushman p/s u/g n ok
|
ELE18-00336
| Electrical Rough-In | 3/27/2018 | 3/28/2018 | 3/28/2018 10:14:24 AM | A | PASS |
|
|
Tile floor heat Phone #: ###-#### Inspection requested via web by Greg Idsinga Ok cover floor heat mstr.
|
ELE18-01135
| Rough-In Permanent Service | 3/27/2018 | 3/28/2018 | 3/28/2018 9:26:29 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk p/s u/g n ok
|
ELE18-01165
| Rough-In Permanent Service | 3/27/2018 | 3/28/2018 | 3/28/2018 9:04:57 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Robert Schroder p/s u/g n ok
|
ELE13-02851
| ELE-Aging Inspection | 3/28/2018 | 3/28/2018 | 3/28/2018 7:19:15 AM | | DONE |
|
|
Please call with update on job, or schedule for a final inspection.
|