Inspections for the day of: Wednesday, March 28, 2018.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-00194 ELE-Aging Inspection3/28/20183/28/20183/29/2018 7:51:22 AM DONE
Waiting on homeowner.
ELE18-01176 Permanent Service3/28/20183/28/20183/28/2018 2:00:16 PMPPASS
Need inspection to cover trench and approve service swing. Phone #: ###-#### Inspection requested via web by Alan Lusk p/s o/h n ok. 100a brkr in meter main needs to be in lowest position of brkr spaces. All other spaces limited to 70a max. Will need to see upon final.
ELE18-01090 Rough-In Permanent Service3/28/20183/28/20183/28/2018 1:15:43 PMPPASS
Service change should be ready this afternoon. Please call ahead to confirm. Phone #: ###-#### Inspection requested via web by William Andrews p/s o/h rec ok. Service inspection only, no RI. New 200a meter main mounted up high to accomodate for new deck to be built. 2 grd rods. Existing plumbing changed to poly.
ELE18-01178 Electrical Rough-In3/28/20183/28/20183/28/2018 12:35:19 PMPPASS
Garage rough in only and new service on garage. Phone #: ###-#### Inspection requested via web by John Harvey Ok cover garage.
ELE18-01119 Permanent Service3/28/20183/28/20183/28/2018 11:45:34 AMPPASS
Phone #: ###-#### Inspection requested via web by Trevor Soesbe p/s o/h rec ok. Existing water bond there and installed a long with 2 grd rods.
ELE18-01178 Permanent Service3/28/20183/28/20183/28/2018 11:44:33 AMPPASS
p/s o/h n ok
ELE18-00741 Electrical Rough-In3/28/20183/28/20183/28/2018 11:37:06 AMPCANC
Grid ceiling inspection Phone #: ###-#### >> Inspection requested via web by steve sellers Inspection cancelled from web by: steve sellers
ELE18-01166 Electrical Rough-In3/27/20183/28/20183/28/2018 10:49:07 AMAPASS
Master bathroom remodel. Homeowner should be home all day, Phone #: ###-#### Inspection requested via web by Shaun Kirkman Ok cover mstr bath.
ELE18-01121 Rough-In Permanent Service3/26/20183/28/20183/28/2018 10:14:46 AMAPASS
Phone #: ###-#### Inspection requested via web by Emmet Bushman p/s u/g n ok
ELE18-00336 Electrical Rough-In3/27/20183/28/20183/28/2018 10:14:24 AMAPASS
Tile floor heat Phone #: ###-#### Inspection requested via web by Greg Idsinga Ok cover floor heat mstr.
ELE18-01135 Rough-In Permanent Service3/27/20183/28/20183/28/2018 9:26:29 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk p/s u/g n ok
ELE18-01165 Rough-In Permanent Service3/27/20183/28/20183/28/2018 9:04:57 AMAPASS
Phone #: ###-#### Inspection requested via web by Robert Schroder p/s u/g n ok
ELE13-02851 ELE-Aging Inspection3/28/20183/28/20183/28/2018 7:19:15 AM DONE
Please call with update on job, or schedule for a final inspection.