MEC19-01237
| Final | 3/28/2019 | 3/28/2019 | 3/28/2019 4:27:49 PM | P | PASS |
|
|
Homeowner Raelin Gibb ###-####. Inspect after 1 PM please Phone #: ###-#### Inspection requested via web by Mary LaFayette - A/C coil co ok
|
MEC19-01241
| Final | 3/27/2019 | 3/28/2019 | 3/28/2019 3:13:04 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek - furnace ac coil co ok
|
MEC19-01241
| Pressure Test | 3/27/2019 | 3/28/2019 | 3/28/2019 3:12:48 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Floyd Floyd Peek - 5lb flue pressure test ok
|
MEC19-01160
| Rough-in | 3/27/2019 | 3/28/2019 | 3/28/2019 2:51:31 PM | P | NR |
|
|
Pressure test Phone #: ###-#### Inspection requested via web by Lynn Johnston - pressure test pass - a few items that need finished like the condensate drain needs finished to the drain - exhaust fan needs sealed at elbow - 8" elbow above unit needs sealed - make sure to have Man J. onsite for R/I
|
MEC19-01160
| Pressure Test | 3/28/2019 | 3/28/2019 | 3/28/2019 2:49:08 PM | P | PASS |
|
|
Pressure test Phone #: ###-#### Inspection requested via web by Lynn Johnston - 20lb gas pressure test ok - tagged meter location
|
MEC18-03267
| Final | 3/28/2019 | 3/28/2019 | 3/28/2019 2:24:46 PM | P | PASS |
|
|
Call ahead to Sarah at ###-#### when in route Phone #: ###-#### Inspection requested via web by Sabrina DeHority - furnace ac coil co ok
|
MEC19-00878
| Final | 3/28/2019 | 3/28/2019 | 3/28/2019 2:15:57 PM | P | PASS |
|
|
Please call home owner to schedule time to get in. Gina 208 901 0951 Phone #: ###-#### Inspection requested via web by Rene Neumeyer - final ok
|
MEC18-02939
| Final | 3/27/2019 | 3/28/2019 | 3/28/2019 2:08:44 PM | P | PASS |
|
|
Please inspect as late as possible tomorrow afternoon and call 30 minutes prior to showing up so the customer can be contacted or Dam can meet you there. Call.Sam when heading that way. Thank you Phone #: ###-#### Inspection requested via web by Geff Blecha - final ok
|
MEC19-00786
| Rough-in | 3/27/2019 | 3/28/2019 | 3/28/2019 10:56:45 AM | A | PASS |
|
|
HHS (29/1 Harris North)
Garage Code: 4224 Phone #: ###-#### Inspection requested via web by Dan Otero - fireplace R/I ok
|
MIS19-00067
| MEC-Conference | 3/27/2019 | 3/28/2019 | 3/28/2019 10:46:09 AM | A | FAIL |
|
|
9:00 AM meet time contact Chip Phone #: ###-####
- Four water heaters one on deck outside, two below deck inside makeshift laundry room, and one in garage are all missing flue venting
- Water heaters looked like they were trying to be used for hydronics heating
- In structure below outside deck there is a barrel style wood stove sitting on the floor with clearance issues and most likely not UL listed. Single wall flue pipe running outside has clearances issues from stove to termination point and needs supported in approved manner. Flue pipe also has hydronics style piping wraped around it.
- Gas fired dryer below deck has a flue not connected and lint blown everywhere
- Branch line off of main gas line has a shut off valve and a flex not connected to anything that needs capped off
- Gas lines are missing sediment traps at all appliances
- Gas line seems like it might be under sized. Long lengths and several appliances hooked up through out house
|
MEC19-00181
| Rough-in | 3/27/2019 | 3/28/2019 | 3/28/2019 10:08:14 AM | A | PASS |
|
|
mARK Phone #: ###-#### -R/I ok
|
MEC18-03268
| Mec-Aging Inspection | 3/28/2019 | 3/28/2019 | 3/28/2019 10:06:09 AM | | DONE |
|
|
Called western and talked with office about their mechanical aging permit. schedule inspection with homeowner if work is finished. Permit will expire in 180 days if not active
|
MEC19-01214
| Final | 3/27/2019 | 3/28/2019 | 3/28/2019 9:03:04 AM | A | PASS |
|
|
Homeowner Jan Dowell, ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - A/C coil co ok
|
MEC18-03269
| Mec-Aging Inspection | 3/28/2019 | 3/28/2019 | 3/28/2019 8:39:57 AM | | DONE |
|
|
Called Jims and talked with office about their mechanical aging permit. Please schedule inspection with homeowner. This permit will expire in 180 days if not active.
|
MEC18-03267
| Mec-Aging Inspection | 3/28/2019 | 3/28/2019 | 3/28/2019 8:35:46 AM | | DONE |
|
|
Called Advanced and talked with Sabrina about their mechanical aging permit. If corrections are finished schedule inspection with homeowner. This permit will expire in 180 days if not active
|
MEC19-00162
| Rough-in | 3/27/2019 | 3/28/2019 | 3/28/2019 8:30:57 AM | A | PASS |
|
|
inspection for restrooms approved for cover. Steve is your contact Phone #: ###-#### Inspection requested via web by Kim Adams - hard lid cover for restrooms ok supply and exhaust ok
|
MEC18-03288
| Mec-Aging Inspection | 3/28/2019 | 3/28/2019 | 3/28/2019 8:18:06 AM | | DONE |
|
|
Called Mcfate Heating and talked with Sarah about their mechanical aging permit. If work is finished please schedule inspection with homeowner. Permit will expire in 180 days if not active
|