Inspections for the day of: Friday, March 29, 1996.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Soden
TitleCODE OFFICER
Phone #340-1274
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM95-01713 INSP - Plumbing Rough-in3/28/19963/29/19963/30/1996 12:00:00 AMAPASS
ROUGH IN ON 3RD AND 4TH FLOOR.
PLM95-00410 INSP - Final3/29/19963/29/19963/29/1996 12:00:00 AM PASS
/ / 347 - final o/k 3/29/6 347
PLM95-01713 INSP - Plumbing Rough-in3/29/19963/29/19963/29/1996 12:00:00 AM FAIL
/ / 347 - DRAIN TEST FAILED 3/29/6 347
PLM95-01713 INSP - Plumbing Rough-in3/29/19963/29/19963/29/1996 12:00:00 AM PASS
/ / 347 - CORE AND SHELL ROUGH IN FINAL PASS
PLM96-00446 INSP - Plumbing Rough-in3/29/19963/29/19963/29/1996 12:00:00 AM PASS
/ / 347 - R/I O/K W/C 1 BASIN 1 TUB 1 W/B 1 W/H 1 K/S 1
PLM96-00506 INSP - Sewer line3/29/19963/29/19963/29/1996 12:00:00 AM PASS
/ / 347 - SEWERLINE O/K 3/29/6 347
PLM96-00579 INSP - Plumbing Rough-in3/29/19963/29/19963/29/1996 12:00:00 AM PART
/ / 347 - CONFERENCE DISCUSSED AND INSTRUCTED INSTALLATION PROCEDURES 3/29/6 347
PLM96-00604 INSP - Sprinkler & Backflow3/29/19963/29/19963/29/1996 12:00:00 AM PASS
/ / 347 - SRINKLER 0/K 3/29/6 347
PLM96-00711 INSP - Sewer line3/29/19963/29/19963/29/1996 12:00:00 AM NR
/ / 347 - SEWER NOT READY 3/29/6 347
PLM96-00711 INSP - Sewer line3/28/19963/29/19963/29/1996 12:00:00 AMANR
03/29/96 347 - NOT READY AGAIN 3/29/6
PLM96-00715 INSP - Plumbing Rough-in3/29/19963/29/19963/29/1996 12:00:00 AMPPASS
03/29/96 347 - 9 FIXTURES W/C 2 BASIN 2 TUB 2 SINK 1 W/B 1 W/H 1 R/I O/K 3/29/6 347
PLM96-00721 INSP - Water lines3/29/19963/29/19963/29/1996 12:00:00 AMPPASS
03/29/96 347 - READY AT 3:00 waterline ok 3/29/6 347 ì
PLM96-00672 INSP - Plumbing Rough-in3/29/19963/29/19963/29/1996 12:00:00 AMPFAIL
03/29/96 347 - ROUGH IN FAILED DRAIN TEST REINSPECTION FEE 20.00
PLM96-00384 INSP - Final3/29/19963/29/19963/29/1996 12:00:00 AMPPASS
03/29/96 347 - W/C 2 BASIN 3 TUB 1 SHR 2 SINK 1 W/B 1 W/H 1 W/S 1 FINAL O/K 3/29/6 347
PLM96-00446 INSP - Final3/29/19963/29/19963/29/1996 12:00:00 AMPPASS
03/29/96 347 - THERE HAS BEEN A PARTIAL ROUGH IN DONE. HE SAYS IT IS REA FINAL O/K 3/29/6 347 W/C 1 BASIN 1 TUB 1 W/H 1