Inspections for the day of: Friday, March 29, 2002.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-00810 Final3/26/20023/29/20023/29/2002 12:00:00 AMAFAIL
###-#### p/s new circuits to cook top oven dryer and computer need to derate conductors clearence for mast and 314.43 no screws in nonmetallic boxes called see jf for details 3/29/2002 11:49:58 AM
ELE02-00748 Permanent Service3/28/20023/29/20023/29/2002 12:00:00 AMACANC
###-####
ELE02-00893 Rough-In Permanent Service3/28/20023/29/20023/29/2002 12:00:00 AMAPASS
###-#### darrell r/i ok

p/s o/h new ok 3/29/2002 10:19:05 AM
ELE02-00725 Final3/28/20023/29/20023/29/2002 12:00:00 AMAFAIL
Scheduled by Inspector: 315 On 3/28/2002 4:23:33 PM contractor never called too set up time of inspection called 3/29/2002 5:30:16 PM
ELE02-00748 Permanent Service3/28/20023/29/20023/29/2002 12:00:00 AMAPASS
per ser bud ###-####

p/s u/g new ok 3/28/2002 4:45:47 PM
ELE02-00747 Permanent Service3/28/20023/29/20023/29/2002 12:00:00 AMAPASS
bud- ###-####--per ser

p/s u/g new ok 3/28/2002 4:46:20 PM
ELE02-00846 Rough-In Permanent Service3/28/20023/29/20023/29/2002 12:00:00 AMAPART
###-#### andy

p/s o/h rec. ok

cor. posted for r/i called220.32(C) 30 circuit for W H 250.8 no S M S, seal all unused openings tighten lugat bond bushing , 3/29/2002 11:00:17 AM
ELE01-02856 Final3/28/20023/29/20023/29/2002 12:00:00 AMAPASS
###-#### andy ok 3/29/2002 10:28:33 AM
ELE01-02173 Electrical Rough-In3/29/20023/29/20023/29/2002 12:00:00 AMPPART
###-#### DAN ceiling above pool ok 3/29/2002 5:08:50 PM
ELE02-00591 Final3/29/20023/29/20023/29/2002 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 03/29/2002 at 08:32:35. Contact: ###-####. sign ok only needs electrical contractor and permit to wire power to sign 3/29/2002 4:17:46 PM
ELE02-00878 Rough-In Permanent Service3/29/20023/29/20023/29/2002 12:00:00 AMPFAIL
bill ###-#### r/i & ser--back door to house will be open cor. posted called support mast grd within 5 ft and bond around all fittins that isolate water piping, box size grd boxes 406.3
grd recepts on ungrounded system, 314.17 see JF for details C O W 3/29/2002 4:06:28 PM
ELE02-00599 Electrical Rough-In3/29/20023/29/20023/29/2002 12:00:00 AMPPASS
ABOVE CEILING ###-#### WARREN ok 3/29/2002 5:28:12 PM