Inspections for the day of: Thursday, March 29, 2007.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-02363 Rough-In Permanent Service3/29/20073/29/20073/29/2007 4:16:16 PMPPART
Requesting Underground Inspection - Open Trench SW Corner of House .. Questions Call Rick @ ###-#### Phone #: ###-####
ELE07-00512 Electrical Rough-In3/28/20073/29/20073/29/2007 3:41:24 PMPFAIL
Request for rough-in inspection Phone #: ###-####
250.148 Continuity and Attachment of Equipment Grounding Conductors to Boxes.
(A) Metal Boxes. A connection shall be made between the one or more equipment grounding conductors and a metal box
300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points.
314.16 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies.
Boxes and conduit bodies shall be of sufficient size to provide free space for all enclosed conductors.
300.4 Protection Against Physical Damage.
Where subject to physical damage, conductors shall be adequately protected.
(D) Cables and Raceways Parallel to Framing Members.

334.30 Securing and Supporting.
Nonmetallic-sheathed cable shall be secured by staples, cable ties, straps, hangers, or similar fittings designed and installed so as not to damage the cable at intervals not exceeding 1.4 m (41/2 ft) and within 300 mm (12 in.) of every cabinet, box, or fitting. Flat cables shall not be stapled on edge.
110.12 Mechanical Execution of Work.
Electrical equipment shall be installed in a neat and workmanlike manner.
(A) Unused Openings. Unused cable or raceway openings in boxes, raceways, auxiliary gutters, cabinets, cutout boxes, meter socket enclosures, equipment cases, or housings shall be effectively closed
ELE06-03341 Final3/29/20073/29/20073/29/2007 2:40:48 PMPFAIL
shawn; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt
210.52 Dwelling Unit Receptacle Outlets.
(E) Outdoor Outlets. …At front and back of the dwelling
410.8 Luminaires (Fixtures) in Clothes Closets.
(C) Luminaire (Fixture) Types Not Permitted. Incandescent luminaires (fixtures) with open or partially enclosed lamps and pendant luminaires (fixtures) or lampholders shall not be permitted.
210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
(A) Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (8) shall have ground-fault circuit-interrupter protection for personnel.
(6) Kitchens
ELE07-01038 Conference3/29/20073/29/20073/29/2007 1:34:51 PMPPART
kevin; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
talked about svc change
ELE06-01164 Final3/29/20073/29/20073/29/2007 12:43:14 PMPNR
suc
ELE05-04007 Final3/29/20073/29/20073/29/2007 11:39:29 AMPNR
suc
ELE07-00999 Electrical Rough-In3/28/20073/29/20073/29/2007 9:39:00 AMAPASS
Please call Jim 30 min. prior. ###-#### Request made by Shawna Phone #: ###-####
ELE07-01030 Electrical Rough-In3/28/20073/29/20073/29/2007 9:01:30 AMAPASS
Trent pls call for access; Phone #: ###-#### Internet Inspection Request from: Stacie Backus
ELE07-00737 Final3/28/20073/29/20073/29/2007 8:33:37 AMAPASS
Jessie; Phone #: ###-#### Internet Inspection Request from: Stacie Backus