Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC12-00767 Conference3/28/20123/29/20123/29/2012 4:36:33 PMPPART
grease duct ok, looked at in shop
MEC12-00936 Rough-in3/28/20123/29/20123/29/2012 3:47:02 PMPPASS
MEC12-00936 Final3/29/20123/29/20123/29/2012 3:46:53 PMPPASS
MEC12-00944 Final3/29/20123/29/20123/29/2012 2:47:06 PMPPASS
MEC12-00948 Final3/29/20123/29/20123/29/2012 2:08:03 PMPPASS
MEC12-00923 Rough-in3/27/20123/29/20123/29/2012 1:25:11 PMPPASS
MEC12-00913 Final3/28/20123/29/20123/29/2012 1:24:58 PMPPASS
MEC12-00933 Final3/28/20123/29/20123/29/2012 11:25:29 AMAFAIL
need to run drain from pan under water heater to outdoors and replace flex with full 3/4" I.D. pipe at t/p pop off
MEC12-00927 Final3/28/20123/29/20123/29/2012 10:57:19 AMAPASS
MEC11-02335 Rough-in3/28/20123/29/20123/29/2012 10:36:56 AMAPART
Inspection in Area D, E & F duct ok
MEC12-00802 Final3/28/20123/29/20123/29/2012 9:53:31 AMAPASS
MEC12-00926 Final3/28/20123/29/20123/29/2012 9:36:38 AMAFAIL
p/t drain line has to be full 3/4" I.D., flex not allowed, can use cpvc pipe and glue it
MEC12-00931 Pressure Test3/29/20123/29/20123/29/2012 9:20:11 AMAPASS
20#
MEC12-00931 Rough-in3/28/20123/29/20123/29/2012 9:19:57 AMAPASS
duct blaster ok, as manual J
MEC11-03594 Mec-Aging Inspection3/29/20123/29/20123/29/2012 8:45:02 AM CANC