ELE16-00955
| Temporary Service | 3/29/2016 | 3/29/2016 | 3/29/2016 3:04:13 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE16-00954
| Temporary Service | 3/29/2016 | 3/29/2016 | 3/29/2016 2:58:48 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE16-00942
| Electrical Rough-In | 3/29/2016 | 3/29/2016 | 3/29/2016 2:18:04 PM | P | FAIL |
|
|
If you have any questions, please call Clay. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Unable to inspect due to BLDG permit is under review. when issued recall. 320.23- Where cables are run within 7' of attic access install guard strip to protect from physical damage.
|
ELE16-00440
| Final | 3/28/2016 | 3/29/2016 | 3/29/2016 1:35:57 PM | P | FAIL |
|
|
Call if you need access lock box on front door. Phone #: ###-#### Inspection requested via web by robert feller 110.3- Items shall be wired as per manufacturers instructions. Receptacle in light grey room not working. Fans located in shower stalls shall have GFCI protection.. 330.30- MC and flex in millwork or cash wrap shall be secured within 12" of each box. 406.5(D)- Receptacles shall be flush or project from faceplate. Diamond plate areas. 422.30- A disconnecting means shall be provided for tanning bed. 110.25 lockout acceptable. Wiring compartment open. 422.52- Drinking fountain shall have GFCI protection. Unable to locate.
|
ELE16-00940
| Final | 3/29/2016 | 3/29/2016 | 3/29/2016 1:14:52 PM | P | PASS |
|
|
Lighting retro complete. Final ok
|
ELE13-01393
| ELE-Aging Inspection | 3/29/2016 | 3/29/2016 | 3/29/2016 12:09:32 PM | | PASS |
|
|
Waiting on contractorq
|
ELE13-02193
| ELE-Aging Inspection | 3/29/2016 | 3/29/2016 | 3/29/2016 11:24:24 AM | | PASS |
|
|
Still under construction
|
MIS16-00077
| ELE-Final | 3/29/2016 | 3/29/2016 | 3/29/2016 11:14:16 AM | P | PASS |
|
|
Check for permit for electrical Work cover underELE16-00942. Final ok
|
ELE15-03396
| Electrical Rough-In | 3/28/2016 | 3/29/2016 | 3/29/2016 11:12:47 AM | A | PASS |
|
|
We need a ceiling inspection, please. Thank you1 Phone #: ###-#### Inspection requested via web by Stacie Tasker Customer lounge hardlid rough in ok cover
|
ESC15-01622
| General Inspection | 3/29/2016 | 3/29/2016 | 3/29/2016 11:11:57 AM | P | PASS |
|
|
Lot clean some landscape complete. ok
|
ESC15-01562
| General Inspection | 3/29/2016 | 3/29/2016 | 3/29/2016 11:10:58 AM | P | PASS |
|
|
Trash contained ok
|
ELE16-00940
| Electrical Rough-In | 3/29/2016 | 3/29/2016 | 3/29/2016 10:40:26 AM | A | PASS |
|
|
rough in on lighting retrofit Phone #: ###-#### Inspection requested via web by Tim Dunlop Listing confirmed. Rough in ok
|
ELE15-03437
| Final | 3/28/2016 | 3/29/2016 | 3/29/2016 10:18:45 AM | A | PASS |
|
|
Key inside recep at front porch Phone #: ###-#### Inspection requested via web by Robert Schroder Final ok
|
ELE16-00956
| Temporary Service | 3/28/2016 | 3/29/2016 | 3/29/2016 9:46:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn t/s u/g n ok
|
ELE16-00407
| Final | 3/25/2016 | 3/29/2016 | 3/29/2016 9:24:17 AM | A | FAIL |
|
|
garage code.....4200 Phone #: ###-#### Inspection requested via web by Will Sevy 110.3- Devices shall be wired as per manufacturers instructions. Hall 3-way. 314.20- Where box is mounted in combustible materials boxes shall be flush or an extension shall be installed. Outdoor outlets. 406.5- Receptacles shall be secured to box. Front outdoor receptacle. 410.16- Luminaire that can accept incandescent lamps shall not be installed less than 12" of shelf.
|
ELE16-00337
| Final | 3/29/2016 | 3/29/2016 | 3/29/2016 8:46:44 AM | A | PASS |
|
|
code 1234 Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|