ELE18-01189
| Final | 3/29/2018 | 3/29/2018 | 3/29/2018 2:04:07 PM | P | PASS |
|
|
Please Call Shaun Wilcox at ###-#### 30 minutes prior to arrival. Project is located at Suite E of the address. Phone #: ###-#### Inspection requested via web by Scott Campbell
|
ELE17-03724
| Final | 3/29/2018 | 3/29/2018 | 3/29/2018 1:37:52 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn final ok
|
ELE18-01168
| Rough-In Permanent Service | 3/28/2018 | 3/29/2018 | 3/29/2018 1:06:55 PM | P | FAIL |
|
|
Call if you have any question. Phone #: ###-#### Inspection requested via web by MIKE HAGERTY talked about transition from NM cable to THWN befor connection to condensor units 110.3B Listed eqipment shall be installed as per man specs.( Slip joint shall be installed at bottom of riser and expanded to half way mark. 314.17B. Sheathing of NM cable shall extend 1/4in into box. (Kitchen cans)
|
ELE18-01162
| Rough-In Permanent Service | 3/28/2018 | 3/29/2018 | 3/29/2018 1:04:03 PM | P | FAIL |
|
|
Call if you have any questions. thanks Mike Phone #: ###-#### Inspection requested via web by MIKE HAGERTY Talked about transition of NM cable to THWN before connecting to Condensor units. 110.3B Instalation of listed equipment shall be as per man instructions.(Slip joint shall be extended to half way mark)
|
ELE18-01085
| Electrical Rough-In | 3/29/2018 | 3/29/2018 | 3/29/2018 12:22:16 PM | P | PASS |
|
|
under ground // Roger Phone #: ###-#### undrground from house to shop ok to cover
|
ELE18-01092
| Rough-In Permanent Service | 3/28/2018 | 3/29/2018 | 3/29/2018 11:34:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn corrections made rough in ok p/s u/g n ok
|
ELE18-01115
| Final | 3/28/2018 | 3/29/2018 | 3/29/2018 9:45:14 AM | A | NR |
|
|
Neil is contact and this was to fix corrections Phone #: ###-#### Inspection requested via web by Matthew White
|
ELE18-01115
| Electrical Rough-In | 3/29/2018 | 3/29/2018 | 3/29/2018 9:44:49 AM | P | PASS |
|
|
Neil is contact and this was to fix corrections Phone #: ###-#### Inspection requested via web by Matthew White Down bath only ok to cover
|
ELE18-00805
| Electrical Rough-In | 3/28/2018 | 3/29/2018 | 3/29/2018 9:43:44 AM | A | PASS |
|
|
We need a cover. Dave is the site contact. Phone #: ###-#### Inspection requested via web by Stacie Tasker Fire riser room walls and ceiling, NE office, conference rooms. Walls only ok to cover
|
ELE18-00406
| Final | 3/28/2018 | 3/29/2018 | 3/29/2018 7:23:50 AM | P | CANC |
|
|
Pls contact Barry (Electrician) @ ###-#### one hr prior or if you have any questions. Thank you. >> Inspection requested via web by Rob Maes Inspection cancelled from web by: Rob Maes
|