Inspections for the day of: Friday, March 3, 2017.
Number of inspections: 25
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorAndy J. Long
TitleEROSION INSPECTOR
Phone #794-8996
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC17-00077 Site Preparation3/3/20173/3/20173/6/2017 1:14:04 PMPPEND
Brain Phone #: ###-####

Permit sign posted. Vegetation preserved at bottom of site and along sidewalk. Large lot, excavator to store foundation dirt on site but away from perimeter. Will discuss construction entrance when driveway apron is cut. Approved for foundation phase.
ESC16-00406 Tracking Control3/1/20173/3/20173/6/2017 12:20:07 PMPCANC
ESC16-01009 Site Preparation3/3/20173/3/20173/6/2017 8:00:05 AMPCANC
ESC17-00018 General Inspection3/3/20173/3/20173/3/2017 5:12:42 PMPPASS
Turbidity sampling of dewatering operation conducted concurrently with CA Paving John M.

Samples of the discharge from ditch into Walling Creek wetland area were between 47-53 NTU on the City meter. Background turbidity upstream in wetland was 2-3 NTU.

In upstream drainage ditch north of Warm Springs bypass had reading of 5-7 NTU. Samples from water from the end of pipe with sediment sack were 60-63 NTU.

Discharges is currently with compliance limits. It should also be noted that meter used by CA had differing measurements but were also within compliance. They will be sampling 3x daily until operation is complete. Work will occur Saturday, no work Sunday and is scheduled to complete on Monday.

No new corrections requested. Will check in on Monday

ESC15-00378 General Inspection3/3/20173/3/20173/3/2017 4:48:00 PM PEND
revegetation phase...
ESC16-00646 Aging Inspection3/3/20173/3/20173/3/2017 4:47:32 PM CANC
ESC15-01391 General Inspection3/3/20173/3/20173/3/2017 2:34:48 PM CANC
ESC16-01646 Site Preparation3/3/20173/3/20173/3/2017 2:21:44 PMPFAIL
Cameron Phone #: ###-####


Need to install sediment protection on storm drain on Cadet north of site. Permit sign posted.

Verbal Correction Request to Cameron via voicemail. No work started yet. Rescheduled.
ESC16-01645 Site Preparation3/3/20173/3/20173/3/2017 2:21:10 PMPFAIL
Cameron Phone #: ###-####

Need to install sediment protection on storm drain on Cadet north of site. Permit sign posted.

Verbal Correction Request to Cameron via voicemail. No work started yet. Rescheduled.
ESC16-00557 Complaint Inspection3/3/20173/3/20173/3/2017 2:11:49 PMPPEND
investigation of complaint in progress. Dual ESC permits with same contractor. Will clost this one, see ESC16-00885
ESC16-00855 Complaint Inspection3/3/20173/3/20173/3/2017 2:10:13 PMPPEND
installation of water circulating sytem along Logger's Creek. Investigation in progress
ESC16-01404 Random Inspection3/3/20173/3/20173/3/2017 1:36:42 PMAFAIL
No permit signs on site. No regular housekeeping occuring. Need to sweep up sidewalk, gutters and street.
ESC16-01630 General Inspection3/3/20173/3/20173/3/2017 12:27:46 PMAFAIL
Loose dirt and debris around site. Trackout from site. DI filter mat on Edelweiss needs replacement. Working with Stetson and developer to clean up this subdivision.
ESC16-00870 General Inspection3/3/20173/3/20173/3/2017 12:25:36 PMPFAIL
Loose dirt and trackout around site and culdesac. Need to sweep sidewalks and gutters, pick up any loose trash. Check storm drain filter bag.
ESC15-00957 General Inspection3/3/20173/3/20173/3/2017 12:16:06 PM PEND
request for new concrete washout facility issued 3/2. RP for D. Evans construction said one would be installed by next week as well as street sweeping...
ESC14-00432 General Inspection3/3/20173/3/20173/3/2017 11:21:39 AM PEND
All homes complete and common areas lanscaped.

Called Hayden Homes Tom to disclose final ESC requests as noted previously:

- remove all temp DI sediment bags (2 on Basseri and all inlets on southern phase)
- remove sections of remaining silt fence at both ends of 5 mile creek through subdivision
- pick up any remaining windblown trash along creek banks

Tom agreed to have it completed during next week. Site final scheduled for next inspection.
ESC04-00526 DOC - Permit Finaled3/3/20173/3/20173/3/2017 10:58:56 AMPPASS
old expired permit in database. no inspection
ESC04-01456 DOC - Permit Finaled3/3/20173/3/20173/3/2017 10:58:32 AMPPASS
old expired permit in system. no inspection
ESC16-01550 Random Inspection3/3/20173/3/20173/3/2017 10:18:01 AMAPEND
WIP. No trackout or windblown trash issues.

Correction: No ESC permit sign.

Need to post new ESC sign - ESC inspector will post sign next inspection.
ESC16-00819 DOC - Permit Finaled3/3/20173/3/20173/3/2017 10:06:16 AMPPASS
ESC16-00327 Site Final3/3/20173/3/20173/3/2017 9:56:46 AMAPASS
Work complete at new Maverik . Open areas have been landscaped and stabilized. MS4 inlets on Ustick have had DI bags removed, Permanent storm drains installed and free of BMPs. ESC permit conditions satisfied.

Note: open parcel to east of site 12067 Ustick is soon to be a new coffee drive thru. No issues at time of inspection.
ESC15-00547 Site Final3/3/20173/3/20173/3/2017 9:41:41 AMAPASS
Gatehouse subdivision development, vertical construction complete. WIP on carports in parking lot and covered under ESC16-01677. No further inspections on this permit
ESC16-00977 Site Final3/3/20173/3/20173/3/2017 9:34:15 AMAPASS
Work complete and ground around modular building is stabilized landscaped. No construction materials or disturbed area on site. BLD finaled.
ESC15-00547 General Inspection3/3/20173/3/20173/3/2017 9:28:51 AM PASS
Gatehouse apartments are now occupied. MS4 sediment filter mat removed from Ustick, frontage is landscaped stabilized. Some minor work occuring in parking lot with soil stockpile. Need to complete and sweep and remove filter mat from private DI on west side of entrance. No immediate corrections.
ESC16-00430 General Inspection3/3/20173/3/20173/3/2017 9:22:09 AM PASS
WIP. Construction entrance in good condition. No trackout, discharges, or loose dirt on sidewalk observed.