Inspections for the day of: Wednesday, March 30, 2005.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE04-01163 ELE-Aging Inspection3/30/20053/30/20053/30/2005 12:00:00 AM PASS
ok corrections made 3/30/2005 7:54:12 AM
ELE04-01349 ELE-Aging Inspection3/30/20053/30/20053/30/2005 12:00:00 AM CANC
called contractor has never got back to me 3/30/2005 7:17:55 AM
ELE04-01475 ELE-Aging Inspection3/30/20053/30/20053/30/2005 12:00:00 AM CANC
no response back from contractor 3/30/2005 7:17:12 AM
ELE05-01016 Electrical Rough-In3/29/20053/30/20053/30/2005 12:00:00 AMAPART
Scheduled by a contractor via Hello! on 3/29/2005 at 3:14:57 PM. Contact: ###-####. u/g ok corrections made 3/30/2005 7:35:29 AM
ELE05-00141 Final3/29/20053/30/20053/30/2005 12:00:00 AMAFAIL
Scheduled by a contractor via Hello! on 3/29/2005 at 3:26:10 PM. Contact: ###-####. cor. posted called 314.23(D)(2)&300.11(A) support boxes and cables, 330.30(B&C) & 300.11 support cables and raceways 358.30(A) 400.8(5) no cords above ceiling, 314.27(D) listed fan boxes needed, seal opening in sub panel, 3/30/2005 11:32:35 AM
ELE05-01054 Electrical Rough-In3/29/20053/30/20053/30/2005 12:00:00 AMAPASS
###-#### - darrell ok 3/30/2005 9:52:00 AM
ELE05-01055 Electrical Rough-In3/29/20053/30/20053/30/2005 12:00:00 AMAPASS
###-#### - darrell ok 3/30/2005 9:52:35 AM
ELE05-01056 Electrical Rough-In3/29/20053/30/20053/30/2005 12:00:00 AMAPASS
###-#### - darrell ok 3/30/2005 9:53:02 AM
ELE05-01054 Permanent Service3/30/20053/30/20053/30/2005 12:00:00 AMAPASS
p/s u/g new ok
ELE05-01055 Permanent Service3/30/20053/30/20053/30/2005 12:00:00 AMAPASS
p/s u/g new ok
ELE05-01056 Permanent Service3/30/20053/30/20053/30/2005 12:00:00 AMAPASS
p/s u/g new ok
ELE05-01057 Permanent Service3/30/20053/30/20053/30/2005 12:00:00 AMAPASS
p/s u/g new ok
ELE04-03671 Electrical Rough-In3/30/20053/30/20053/30/2005 12:00:00 AMPPART
ceiling grid-- alan; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok, needs listed fan box or support fan to structure, need to check listing of track lighting cord fed 3/30/2005 12:51:52 PM
ELE04-03527 Final3/30/20053/30/20053/30/2005 12:00:00 AMPPART
Phone #: ###-#### Internet Inspection Request from: Kathy Briggs ceiling ok needs fan boxes or support fans from structure, check listeng on cord fed track lighting 3/30/2005 12:49:09 PM
ELE04-03527 Final3/30/20053/30/20053/30/2005 12:00:00 AMPNR
called 3/30/2005 4:32:34 PM
ELE05-01049 Electrical Rough-In3/30/20053/30/20053/30/2005 12:00:00 AMPFAIL
cor. posted 210.52(A) shall provide required outlet spacing for downstairs bed remodel, and new room added above garage, shall expose, or remove all wiring done by owner without inspection, note need approved plans at job site 3/30/2005 2:39:02 PM
ELE05-01057 Electrical Rough-In3/29/20053/30/20053/30/2005 12:00:00 AMPPASS
###-#### - darrell ok 3/30/2005 9:53:30 AM
ELE05-01051 Final3/30/20053/30/20053/30/2005 12:00:00 AMPPASS
Call Elma to meet, ###-####.; Phone #: ###-#### Internet Inspection Request from: Dana Moyer ok 3/30/2005 1:23:36 PM
ELE05-01065 Permanent Service3/30/20053/30/20053/30/2005 12:00:00 AMPFAIL
THANK YOU ; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH cor. posted called needs all grd and bonding complete water system, steel structure, other metal piping 3/30/2005 3:24:28 PM
ELE05-00420 Final3/30/20053/30/20053/30/2005 12:00:00 AMPPASS
jim; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie final ok for r/i work only, done by MtnPower, owner secured new permit,ele05-01049, to finish job 3/30/2005 2:23:41 PM