ELE05-01046
| Rough-In Permanent Service | 3/29/2005 | 3/30/2005 | 3/30/2005 12:00:00 AM | A | PASS |
|
|
###-#### ric ok p/s u/g n ok 3/30/2005 8:49:08 AM
|
ELE05-00832
| Electrical Rough-In | 3/29/2005 | 3/30/2005 | 3/30/2005 12:00:00 AM | A | PASS |
|
|
###-#### Jerry ric ok for room addition 3/30/2005 9:43:36 AM
|
ELE05-00554
| Electrical Rough-In | 3/29/2005 | 3/30/2005 | 3/30/2005 12:00:00 AM | A | NH |
|
|
please contact Duane, thank you.; Phone #: ###-#### Internet Inspection Request from: Wendy Waters called left message, don't know what to look at 3/30/2005 8:28:30 AM
|
ELE05-01048
| Electrical Rough-In | 3/29/2005 | 3/30/2005 | 3/30/2005 12:00:00 AM | A | PASS |
|
|
###-#### - brandon called, left message, told about 1 1/4" and that I marked several places . Left survey. BCC job id shall be posted, 300.4(D) ric ok, 3/30/2005 9:56:56 AM
|
ELE05-01048
| Permanent Service | 3/30/2005 | 3/30/2005 | 3/30/2005 12:00:00 AM | A | PASS |
|
|
p/s u/g n ok
|
ELE05-01041
| Electrical Rough-In | 3/29/2005 | 3/30/2005 | 3/30/2005 12:00:00 AM | A | FAIL |
|
|
###-#### dennis called left message and corr notice. 250.24(A)(1) gec shall be connected to grounded conductor lug, 110.12(A) unused openings shall be closed in panel, 314.23(C)(1) boxes shall be attached to framing members in new work 3/30/2005 8:15:02 AM
|
ELE04-03683
| Electrical Rough-In | 3/30/2005 | 3/30/2005 | 3/30/2005 12:00:00 AM | P | NR |
|
|
craig - ###-#### called contr and said all make-up to be done and mud rings before inspection 3/30/2005 1:40:07 PM
|
ELE05-00639
| Final | 3/30/2005 | 3/30/2005 | 3/30/2005 12:00:00 AM | P | PART |
|
|
please call to set time; Phone #: ###-#### Internet Inspection Request from: Nikki Day met with elect, they are adding some straps and gfci protection in the kitchen area. 3/30/2005 1:07:27 PM
|
ELE05-00423
| Final | 3/30/2005 | 3/30/2005 | 3/30/2005 12:00:00 AM | P | PASS |
|
|
###-#### - kim ok to final 3/30/2005 4:43:02 PM
|
ELE05-01047
| Permanent Service | 3/30/2005 | 3/30/2005 | 3/30/2005 12:00:00 AM | P | PASS |
|
|
p/s u/g n ok
|
ELE05-01050
| Electrical Rough-In | 3/29/2005 | 3/30/2005 | 3/30/2005 12:00:00 AM | P | PART |
|
|
Scheduled by a contractor via Hello! on 3/29/2005 at 4:56:10 PM. Contact: ###-####. main pool bond ok to cover,need to check equi-potential plane before done 3/30/2005 4:45:10 PM
|
ELE05-01047
| Electrical Rough-In | 3/29/2005 | 3/30/2005 | 3/30/2005 12:00:00 AM | P | PASS |
|
|
###-#### rob called contr about 1 1/4" ric ok, left message 3/30/2005 2:34:45 PM
|