InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03831 Final3/30/20063/30/20063/30/2006 3:47:59 PMPPASS
ok
ELE06-00856 Electrical Rough-In3/30/20063/30/20063/30/2006 3:21:15 PMPPART
Dave -- cover up underground for 2 gates (location of gates: 3750 Orchard, 4465 Industrial St); call 1st before insp; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
u/g both locations ok
ELE06-00125 Electrical Rough-In3/30/20063/30/20063/30/2006 2:32:29 PMPPART
dennis; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
exterior walls only ok
ELE05-04391 Final3/30/20063/30/20063/30/2006 1:22:56 PMPPASS
Ron ###-#### -- reinspection ok
ELE05-02847 Final3/30/20063/30/20063/30/2006 12:41:27 PMPPASS
butch --re-insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok no card
ELE05-04449 ELE-Aging Inspection3/30/20063/30/20063/30/2006 11:46:01 AM FAIL
see added r/i
ELE05-04449 Electrical Rough-In3/30/20063/30/20063/30/2006 11:45:35 AMAFAIL
corr. called 344.46 bushings for rigid nipples,600.5(C)(3),410.15(B) needs access st pole opposite of nipples, grd at hand hole,314.17(A&B) conn. for low voltage cable at jbox
ELE06-00993 Permanent Service3/29/20063/30/20063/30/2006 10:11:52 AMACANC
ufer concrete inspection Internet Inspection Request from: Melyne Davis no p/s electorde ok for dirt cover
ELE06-00993 Electrical Rough-In3/30/20063/30/20063/30/2006 10:11:12 AMAPASS
ufer concrete inspection Internet Inspection Request from: Melyne Davis ok to cover electrode with dirt
ELE06-00926 Electrical Rough-In3/29/20063/30/20063/30/2006 9:44:18 AMAPART
Wayne -- underground; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong u/g for 2 pole lights, and gas island
ELE06-01084 Rough-In Permanent Service3/29/20063/30/20063/30/2006 8:59:13 AMAPASS
ron ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie shell core wiring , called needs conn. for GEC
p/s u/g new ok
ELE06-01085 Rough-In Permanent Service3/29/20063/30/20063/30/2006 8:58:26 AMAPASS
ron ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie shell core wiring ok called needs conn. for GEC
p/s u/g new ok
ELE06-01054 Final3/30/20063/30/20063/30/2006 12:00:00 AMPCANC
Tim; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong /// Cancel per Tim (BenCorp) 3-30-06 eus