ESC10-00119
| General Inspection | 3/30/2010 | 3/30/2010 | 3/30/2010 4:06:01 PM | P | PASS |
|
|
looked ok
|
ELE10-00643
| Final | 3/30/2010 | 3/30/2010 | 3/30/2010 4:05:20 PM | P | PASS |
|
|
Contact: Shane Korte Inspection requested from web by: Deb Gooden Phone #: ###-#### ok to final, no esc this project
|
ESC10-00087
| General Inspection | 3/30/2010 | 3/30/2010 | 3/30/2010 3:24:55 PM | P | PASS |
|
|
looked ok
|
ESC10-00039
| General Inspection | 3/30/2010 | 3/30/2010 | 3/30/2010 3:24:19 PM | P | PASS |
|
|
looked ok
|
ESC10-00054
| General Inspection | 3/30/2010 | 3/30/2010 | 3/30/2010 3:23:40 PM | P | PASS |
|
|
looked ok
|
ESC09-00432
| General Inspection | 3/30/2010 | 3/30/2010 | 3/30/2010 3:23:06 PM | P | PASS |
|
|
looked ok
|
ELE10-00638
| Electrical Rough-In | 3/30/2010 | 3/30/2010 | 3/30/2010 3:18:03 PM | P | PASS |
|
|
Mike Phone #: ###-#### ric ok, no esc
|
ELE10-00623
| Rough-In Permanent Service | 3/30/2010 | 3/30/2010 | 3/30/2010 2:11:46 PM | P | CANC |
|
|
Any questions please call, thx. Inspection requested from web by: Stephen Kren Phone #: ###-#### see ri and p/s
|
ELE10-00623
| Electrical Rough-In | 3/30/2010 | 3/30/2010 | 3/30/2010 1:46:20 PM | P | FAIL |
|
|
Any questions please call, thx. Inspection requested from web by: Stephen Kren Phone #: ###-#### called, left correction notice, NEC 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 334.23 shall protect nm cable within 6' of attic access, NOTE corrections shall be made within 5 working days
|
ELE10-00623
| Permanent Service | 3/30/2010 | 3/30/2010 | 3/30/2010 1:40:31 PM | P | PASS |
|
|
Any questions please call, thx. Inspection requested from web by: Stephen Kren Phone #: ###-#### p/s u/g n ok
|
ELE09-01989
| Final | 3/30/2010 | 3/30/2010 | 3/30/2010 1:19:26 PM | P | PART |
|
|
Pat Phone #: ###-#### met electrician, needs puck lights, tighten outside receptacles, kitchen receptacles, outside back terminations, bond water piping, no loose uf wiring, change room count on permit, add electric heat, check for 600a service, will call back later
|
ELE10-00529
| Final | 3/30/2010 | 3/30/2010 | 3/30/2010 12:24:34 PM | P | FAIL |
|
|
Inspection requested from web by: Scott Campbell Phone #: ###-#### called, left correction notice, NEC 590.6(B)(1) shall provide gfci protection for 20A receptacle, 408.4 shall provide circuit directory, NOTE: corrections shall be made in 5 working days or further action will be taken, such as removal of power, no esc
|
ELE09-00554
| Final | 3/16/2010 | 3/30/2010 | 3/30/2010 10:35:54 AM | A | PASS |
|
|
Aging deadline. ok to final, no esc
|
ELE09-02110
| Electrical Rough-In | 3/29/2010 | 3/30/2010 | 3/30/2010 10:18:52 AM | A | PASS |
|
|
Please Call To Meet Desk ###-#### Cell ###-#### Inspection requested from web by: mark morris Phone #: ###-#### ok to cover hard lid only, no esc this project
|
ELE10-00627
| Rough-In Permanent Service | 3/29/2010 | 3/30/2010 | 3/30/2010 10:00:43 AM | A | PASS |
|
|
dino Phone #: ###-#### called, left message ric ok, p/s u/g n ok
|
ELE10-00590
| Final | 3/29/2010 | 3/30/2010 | 3/30/2010 9:15:53 AM | A | FAIL |
|
|
Please call prior to arrival for access info - ###-#### Inspection requested from web by: John Edwards Phone #: ###-#### called contractor, shall check grounding and recall, no esc this project
|
ELE10-00277
| Final | 3/29/2010 | 3/30/2010 | 3/30/2010 8:44:46 AM | A | PASS |
|
|
Lock box code is 1290. Any questions or concerns call Clay @ ###-####. Thanks. Inspection requested from web by: Clay Morgan Phone #: ###-#### ok to final
|
ELE10-00246
| Final | 3/29/2010 | 3/30/2010 | 3/30/2010 8:13:34 AM | A | PASS |
|
|
Inspection requested from web by: TOM BICANDI Phone #: ###-#### corrections made, ok to final
|