Inspections for the day of: Tuesday, March 30, 2010.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC10-00119 General Inspection3/30/20103/30/20103/30/2010 4:06:01 PMPPASS
looked ok
ELE10-00643 Final3/30/20103/30/20103/30/2010 4:05:20 PMPPASS
Contact: Shane Korte Inspection requested from web by: Deb Gooden Phone #: ###-#### ok to final, no esc this project
ESC10-00087 General Inspection3/30/20103/30/20103/30/2010 3:24:55 PMPPASS
looked ok
ESC10-00039 General Inspection3/30/20103/30/20103/30/2010 3:24:19 PMPPASS
looked ok
ESC10-00054 General Inspection3/30/20103/30/20103/30/2010 3:23:40 PMPPASS
looked ok
ESC09-00432 General Inspection3/30/20103/30/20103/30/2010 3:23:06 PMPPASS
looked ok
ELE10-00638 Electrical Rough-In3/30/20103/30/20103/30/2010 3:18:03 PMPPASS
Mike Phone #: ###-#### ric ok, no esc
ELE10-00623 Rough-In Permanent Service3/30/20103/30/20103/30/2010 2:11:46 PMPCANC
Any questions please call, thx. Inspection requested from web by: Stephen Kren Phone #: ###-#### see ri and p/s
ELE10-00623 Electrical Rough-In3/30/20103/30/20103/30/2010 1:46:20 PMPFAIL
Any questions please call, thx. Inspection requested from web by: Stephen Kren Phone #: ###-#### called, left correction notice, NEC 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 334.23 shall protect nm cable within 6' of attic access, NOTE corrections shall be made within 5 working days
ELE10-00623 Permanent Service3/30/20103/30/20103/30/2010 1:40:31 PMPPASS
Any questions please call, thx. Inspection requested from web by: Stephen Kren Phone #: ###-#### p/s u/g n ok
ELE09-01989 Final3/30/20103/30/20103/30/2010 1:19:26 PMPPART
Pat Phone #: ###-#### met electrician, needs puck lights, tighten outside receptacles, kitchen receptacles, outside back terminations, bond water piping, no loose uf wiring, change room count on permit, add electric heat, check for 600a service, will call back later
ELE10-00529 Final3/30/20103/30/20103/30/2010 12:24:34 PMPFAIL
Inspection requested from web by: Scott Campbell Phone #: ###-#### called, left correction notice, NEC 590.6(B)(1) shall provide gfci protection for 20A receptacle, 408.4 shall provide circuit directory, NOTE: corrections shall be made in 5 working days or further action will be taken, such as removal of power, no esc
ELE09-00554 Final3/16/20103/30/20103/30/2010 10:35:54 AMAPASS
Aging deadline. ok to final, no esc
ELE09-02110 Electrical Rough-In3/29/20103/30/20103/30/2010 10:18:52 AMAPASS
Please Call To Meet
Desk ###-####
Cell ###-#### Inspection requested from web by: mark morris Phone #: ###-#### ok to cover hard lid only, no esc this project
ELE10-00627 Rough-In Permanent Service3/29/20103/30/20103/30/2010 10:00:43 AMAPASS
dino Phone #: ###-#### called, left message ric ok, p/s u/g n ok
ELE10-00590 Final3/29/20103/30/20103/30/2010 9:15:53 AMAFAIL
Please call prior to arrival for access info - ###-#### Inspection requested from web by: John Edwards Phone #: ###-#### called contractor, shall check grounding and recall, no esc this project
ELE10-00277 Final3/29/20103/30/20103/30/2010 8:44:46 AMAPASS
Lock box code is 1290. Any questions or concerns call Clay @ ###-####. Thanks. Inspection requested from web by: Clay Morgan Phone #: ###-#### ok to final
ELE10-00246 Final3/29/20103/30/20103/30/2010 8:13:34 AMAPASS
Inspection requested from web by: TOM BICANDI Phone #: ###-#### corrections made, ok to final