MIS17-00090
| BLD-Conference | 3/24/2017 | 3/24/2017 | | P | |
|
|
Caller stated that it looks like they are building a car port/garage or shed and over property line
|
BLD17-00538
| BLD-Footing | 3/30/2017 | 3/30/2017 | 3/30/2017 5:03:50 PM | P | CANC |
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron. Footings and excavation full of water. Rescheduled inspection for 3-31 in the am.
|
BLD16-02650
| BLD-Wall Bracing | 3/30/2017 | 3/30/2017 | 3/30/2017 2:52:26 PM | P | CANC |
|
|
|
BLD16-02650
| BLD-Framing/Rough-in | 3/30/2017 | 3/30/2017 | 3/30/2017 2:51:55 PM | P | PART |
|
|
Complete fire caulking, repair sheet rock in fire partitions.
|
BLD16-03148
| BLD-Final | 3/29/2017 | 3/30/2017 | 3/30/2017 1:33:36 PM | P | PEND |
|
|
Patrick Phone #: ###-####. Per the fire inspectors notes, a revised floor plan needs to resubmited and approved.
|
BLD16-02020
| BLD-Energy code compliance | 3/30/2017 | 3/30/2017 | 3/30/2017 1:32:23 PM | P | PASS |
|
|
Bill Phone #: ###-####
|
BLD16-02020
| BLD-Framing/Rough-in | 3/30/2017 | 3/30/2017 | 3/30/2017 1:32:12 PM | P | PASS |
|
|
Bill Phone #: ###-####
|
BLD17-00358
| BLD-Footing | 3/29/2017 | 3/30/2017 | 3/30/2017 1:19:00 PM | P | NR |
|
|
Doyle Phone #: ###-####. Excavation is complete. No forms constructed at this time, probably due to weather. Will need to reschedule inspection.
|
BLD16-02650
| BLD-Wall Bracing | 3/29/2017 | 3/30/2017 | 3/30/2017 11:21:59 AM | A | CANC |
|
|
Suite''s 101, 102, 201, 202; Pat Phone #: ###-####. Moved to pm.
|
BLD16-02650
| BLD-Framing/Rough-in | 3/29/2017 | 3/30/2017 | 3/30/2017 11:21:43 AM | A | NR |
|
|
Suite''s 101, 102, 201, 202; Pat Phone #: ###-####. Needs sprinkler rough in inspection. Noted inspection scheduled today for pm. Rerscheduled for pm.
|
BLD17-00459
| BLD-Final | 3/29/2017 | 3/30/2017 | 3/30/2017 11:01:16 AM | A | PASS |
|
|
Korry Phone #: ###-####
|
BLD17-00459
| DOC - Permit Finaled | 3/30/2017 | 3/30/2017 | 3/30/2017 11:00:24 AM | P | PASS |
|
|
|
BLD17-00755
| BLD-Conference | 3/29/2017 | 3/30/2017 | 3/30/2017 10:42:42 AM | A | DONE |
|
|
John-please call 15 minutes prior to meet Phone #: ###-####
|
BLD17-00372
| BLD-Final | 3/29/2017 | 3/30/2017 | 3/30/2017 10:25:20 AM | A | PASS |
|
|
Evan Phone #: ###-####
|
BLD17-00372
| DOC - Permit Finaled | 3/30/2017 | 3/30/2017 | 3/30/2017 10:25:08 AM | P | PASS |
|
|
|
BLD16-03678
| BLD-Wall Bracing | 3/29/2017 | 3/30/2017 | 3/30/2017 10:12:34 AM | A | DONE |
|
|
Need a re-inspect sheet inspection please. Phone #: ###-#### Inspection requested via web by Kim Winkle. Per framer, blocking in portal frame oriantation fixed.
|
BLD16-01070
| BLD-Conference | 3/29/2017 | 3/30/2017 | 3/30/2017 9:52:00 AM | A | DONE |
|
|
Phil Phone #: ###-####
|
BLD16-04540
| BLD-Final | 3/29/2017 | 3/30/2017 | 3/30/2017 9:15:04 AM | A | PASS |
|
|
Korry Phone #: ###-####
|
BLD16-04540
| DOC - Permit Finaled | 3/30/2017 | 3/30/2017 | 3/30/2017 9:14:55 AM | P | PASS |
|
|
|
ESC17-00085
| General Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 9:14:18 AM | A | PART |
|
|
Needs to provide the EsC permit sign.
|
BLD17-00186
| BLD-Framing/Rough-in | 3/30/2017 | 3/30/2017 | 3/30/2017 9:13:32 AM | A | FAIL |
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Brace the gable end upstairs , north side. Strap both sides of 15" glue lam beam to 6x6 post. Strap the 4x8 header to the (2) 2x4 below. Roll block floor joist at garage common wall and beyond entire length. Install OSB on garage common wall and fasten per shear wall schedule. Correction notice issued. Ok to insulate.
|
ESC17-00098
| General Inspection | 3/30/2017 | 3/30/2017 | 3/30/2017 8:46:45 AM | A | PART |
|
|
Provide the ESC permit sign.
|
BLD17-00221
| BLD-Framing/Rough-in | 3/30/2017 | 3/30/2017 | 3/30/2017 8:46:09 AM | A | FAIL |
|
|
Phone #: 2085156235 >> Inspection requested via mobile web by Brian Rodriguez . Fireblock arch in hallway. Complete lateral bracing on A06 truss. Provide the continous bracing on A06 truss as shown on the engineering. Correction notice posted. Ok to insulate.
|