ELE05-00554
| Electrical Rough-In | 3/30/2005 | 3/31/2005 | 3/31/2005 10:42:30 AM | P | CANC |
|
|
Please contact Duane prior to inspection for exact site location, thank you.; Phone #: ###-#### Internet Inspection Request from: Wendy Waters Inspection cancelled from web by: Wendy Waters
|
ELE04-04118
| ELE-Aging Inspection | 3/31/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | | PASS |
|
|
|
ELE04-01679
| ELE-Aging Inspection | 3/31/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | | CANC |
|
|
|
ELE05-01059
| Rough-In Permanent Service | 3/31/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | PASS |
|
|
###-#### r/i ok p/s u/g new ok 3/31/2005 7:49:43 AM
|
ELE05-01058
| Rough-In Permanent Service | 3/31/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | PASS |
|
|
###-#### r/i ok p/s u/g new ok 3/31/2005 7:49:25 AM
|
ELE05-00968
| Electrical Rough-In | 3/30/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | PASS |
|
|
rough in inspection for kitchen remodel Internet Inspection Request from: Andy Rose ok 3/31/2005 9:02:03 AM
|
ELE05-00062
| Final | 3/30/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | FAIL |
|
|
Call Todd Stewart at ###-#### for Garage Code to get inside if needed.; Phone #: ###-#### Internet Inspection Request from: HARVEY REYNA cor. posted called grd and use connector at wiremold boxes recepts not secure at boxes, needs outlets each side of sink island counter 3/31/2005 12:12:54 PM \ 3/31/2005 12:12:58 PM
|
ELE05-00152
| Final | 3/30/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | FAIL |
|
|
Call Todd Stewart at ###-#### for garage code to get in if needed. ; Phone #: ###-#### Internet Inspection Request from: HARVEY REYNA cor. posted called grd wiremold boxes, use romex connectors at wiremold boxes needs outlets each side of sink island outlets not secur in boxes,, needs outlet for counter between range and refer 3/31/2005 12:11:04 PM
|
ELE05-00491
| Final | 3/30/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 3/30/2005 at 6:52:57 PM. Contact: ###-####. called not ready needs show window outlets, and shal not use grid to support wiring, cables and raceways shall not support other cables or raceways 3/31/2005 10:44:40 AM
|
ELE05-00713
| Final | 3/30/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 3/30/2005 at 1:25:09 PM. Contact: ###-####. ok 3/31/2005 8:30:20 AM
|
ELE05-01055
| Rough-In Permanent Service | 3/30/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | DONE |
|
|
Scheduled by a contractor via Hello! on 3/30/2005 at 1:27:03 PM. Contact: ###-####.
|
ELE05-01056
| Rough-In Permanent Service | 3/30/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | DONE |
|
|
Scheduled by a contractor via Hello! on 3/30/2005 at 1:28:30 PM. Contact: ###-####.
|
ELE05-01067
| Final | 3/30/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | NR |
|
|
Scheduled by a contractor via Hello! on 3/30/2005 at 2:14:39 PM. Contact: ###-####. called need access to gas pumps 3/31/2005 1:16:03 PM
|
ELE05-01075
| Electrical Rough-In | 3/30/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | PART |
|
|
under slab\\Bill ###-#### okl 3/31/2005 10:25:34 AM
|
ELE05-00642
| Rough-In Permanent Service | 3/30/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | FAIL |
|
|
Bill ###-#### cor. posted called 210.52(A)&(B) outlet spacing and only what code allows on kit circuit, 300.4(A)(1)&(D), 250.24 terminate GEC to neutral bus, use approved crimp tool 3/31/2005 10:28:12 AM
|
ELE05-00491
| Permanent Service | 3/31/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | A | PASS |
|
|
p/s u/g new for meter ok
|
ELE05-00661
| Permanent Service | 3/31/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | P | PASS |
|
|
p/s u/g new ok
|
ELE05-01065
| Permanent Service | 3/31/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | P | PASS |
|
|
Thank you ; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH p/s o/h rec. ok 3/31/2005 4:18:38 PM
|
ELE05-00661
| Electrical Rough-In | 3/31/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | P | PART |
|
|
ted; Phone #: ###-#### Internet Inspection Request from: Barbara Moore u/g and ser cables in house ok see added p/s 3/31/2005 1:04:01 PM
|
ELE04-04017
| Final | 3/31/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | P | NH |
|
|
Scheduled by a contractor via Hello! on 3/31/2005 at 10:07:59 AM. Contact: ###-####. notice posted called 3/31/2005 3:11:06 PM
|
ELE05-00639
| Final | 3/31/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | P | PASS |
|
|
please call pryor to inspection; Phone #: ###-#### Internet Inspection Request from: Nikki Day ok card signed 3/31/2005 3:45:02 PM
|
ELE05-00867
| Electrical Rough-In | 3/31/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | P | PART |
|
|
Scheduled by a contractor via Hello! on 3/31/2005 at 7:15:55 AM. Contact: ###-####. u/g ok veggie,and deli area 3/31/2005 2:52:59 PM
|
ELE05-00141
| Final | 3/31/2005 | 3/31/2005 | 3/31/2005 12:00:00 AM | P | PART |
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Barbara Moore t/o ok card signed 3/31/2005 2:20:01 PM
|