Inspections for the day of: Thursday, March 31, 2005.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01062 Conference3/30/20053/31/20053/31/2005 12:00:00 AMADONE
Scheduled by a contractor via Hello! on 3/30/2005 at 9:06:22 AM. Contact: ###-####. reviewed power panel re-distribution and bus duct re-moval. Several panels and floors incolved in bldg 5. 3/31/2005 11:12:25 AM
ELE05-00807 Electrical Rough-In3/30/20053/31/20053/31/2005 12:00:00 AMAPART
rex -partail r/i; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie soffits ok to cover 3/31/2005 10:17:27 AM
ELE05-01040 Electrical Rough-In3/30/20053/31/20053/31/2005 12:00:00 AMAPART
ceiling rough in\\###-#### ok for ceiling cover, asked contr about deep mud rings 3/31/2005 8:21:40 AM
ELE05-00799 Permanent Service3/30/20053/31/20053/31/2005 12:00:00 AMAFAIL
wayne; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called, left message, left corr notice, 110.26(F)(1) there shall be no ducts in dedicated elect space 3/31/2005 9:39:18 AM
ELE05-01074 Temporary Service3/30/20053/31/20053/31/2005 12:00:00 AMAFAIL
###-#### - dan called left message, 250.20 system shall be grounded, fee due. 3/31/2005 7:32:52 AM
ELE05-00926 Electrical Rough-In3/30/20053/31/20053/31/2005 12:00:00 AMAPASS
Ufer Ground for cover up; Phone #: ###-#### Internet Inspection Request from: Celinda Winters ok to cover, met contr. 3/31/2005 8:00:43 AM
ELE05-01081 Electrical Rough-In3/30/20053/31/20053/31/2005 12:00:00 AMAPASS
Upstairs bath moved switches for light and fan, moved gfci recep, add 2 j-boxes in wall on bedroom side for extension of circuits. Please call Heath @ ###-#### to schedule access.; Phone #: ###-#### Internet Inspection Request from: Joe Thomas ric ok 3/31/2005 10:00:18 AM
ELE05-00765 Electrical Rough-In3/31/20053/31/20053/31/2005 12:00:00 AMAPASS
ric ok
ELE05-00639 Final3/30/20053/31/20053/31/2005 12:00:00 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Nikki Day 110.3 equip shall be suitable for use, switches on coolers, BCC no violations shall be retained 3/31/2005 9:07:59 AM
ELE04-03108 Final3/31/20053/31/20053/31/2005 12:00:00 AMPCANC
Scheduled by a contractor via Hello! on 3/31/2005 at 9:51:01 AM. see added 3/31/2005 12:35:23 PM
ELE05-00799 Permanent Service3/31/20053/31/20053/31/2005 12:00:00 AMPPASS
###-#### - wayne Called contr, left message to strap 2 mc cables over west panel. p/s u/g n ok. left survey 3/31/2005 1:06:15 PM
ELE05-01083 Final3/31/20053/31/20053/31/2005 12:00:00 AMPPASS
No one home. All work done on outside of house.; Phone #: ###-#### Internet Inspection Request from: Dana Moyer 3/31/2005 1:26:24 PM
ELE05-01085 Temporary Service3/31/20053/31/20053/31/2005 12:00:00 AMPFAIL
###-#### - clyde called contr, left message, 110.12(C) 50A recpt shall not be broken, fee due 3/31/2005 5:14:21 PM
ELE05-01086 Temporary Service3/31/20053/31/20053/31/2005 12:00:00 AMPFAIL
###-#### - clyle called contr, left message, 250.24(B) bond shall be provided for grounded conductor and grounding electrode conductor to ground lug, 110.12(C) recepts shall not be broken 15A and 50A, 590.6(B)(1) 50A recpt shall have gfci protection. fee due 3/31/2005 5:19:26 PM
ELE05-00956 Temporary Service3/31/20053/31/20053/31/2005 12:00:00 AMPPASS
###-#### - clyde t/s u/g n ok 3/31/2005 3:26:39 PM
ELE04-03108 Permanent Service3/31/20053/31/20053/31/2005 12:00:00 AMPPASS
p/s u/g n ok
ELE05-01080 Electrical Rough-In3/31/20053/31/20053/31/2005 12:00:00 AMPPASS
ric garage only
ELE05-01080 Electrical Rough-In3/30/20053/31/20053/31/2005 12:00:00 AMPFAIL
kevin-- ###-#### called left message, 250.92(A)&(B)(4) bonding type locknuts shall be used at service,250.104(A) metal water piping system shall be bonded. Note: locate gndg electrodes 3/31/2005 12:40:18 PM
ELE05-00537 Electrical Rough-In3/30/20053/31/20053/31/2005 12:00:00 AMPPASS
Partial Rough-in SW Corner; Phone #: ###-#### Internet Inspection Request from: Celinda Winters sw office space ric walls ok 3/31/2005 11:38:58 AM
ELE05-00637 Final3/30/20053/31/20053/31/2005 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 3/30/2005 at 2:17:10 PM. Contact: ###-####. ok to final 3/31/2005 3:45:12 PM
ELE05-00537 Electrical Rough-In3/30/20053/31/20053/30/2005 2:59:38 PMACANC
Partial Rough-in SW Corner; Phone #: ###-#### Internet Inspection Request from: Celinda Winters Inspection cancelled from web by: Celinda Winters