PLM09-00316
| Plumbing Rough-in | 3/4/2009 | 3/4/2009 | 3/4/2009 4:05:04 PM | P | PASS |
|
|
|
PLM09-00310
| Final | 3/2/2009 | 3/4/2009 | 3/4/2009 3:39:57 PM | P | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Elisa Worrell-need shutoff valve that will shut off the water heater only.
|
PLM09-00316
| Plumbing Rough-in | 3/4/2009 | 3/4/2009 | 3/4/2009 2:44:27 PM | P | CANC |
|
|
Tim Phone #: ###-####
|
PLM09-00318
| Plumbing Rough-in | 3/4/2009 | 3/4/2009 | 3/4/2009 2:43:57 PM | P | PASS |
|
|
Bryan ###-####
|
ESC09-00042
| BMP Violation | 3/4/2009 | 3/4/2009 | 3/4/2009 2:28:10 PM | P | FAIL |
|
|
left verbal & written correction with rp to put trash in a container or remove from site, need di protection & post esc sign by 3-5-09 pm. will reinspect on 3-6-09
|
ESC08-00954
| BMP Violation | 2/27/2009 | 3/4/2009 | 3/4/2009 1:57:22 PM | A | FAIL |
|
|
eric this reinspect is for the concrete spoils, lanscape contractor is going to remove them any questions call tony ###-####-left verbal correction with rp to clean conrete & stucco from his lot that is on other corner lot to the west of his site, maintain di box & landscapers to clean daily at the end of each day. will reinspect 3-6-09
|
ESC08-00969
| General Inspection | 3/4/2009 | 3/4/2009 | 3/4/2009 11:30:17 AM | P | PASS |
|
|
|
ESC06-01113
| Aging Inspection | 3/4/2009 | 3/4/2009 | 3/4/2009 11:29:50 AM | | PASS |
|
|
|
ESC06-01113
| DOC - Permit Finaled | 3/4/2009 | 3/4/2009 | 3/4/2009 11:29:41 AM | P | PASS |
|
|
|
PLM09-00140
| Plumbing Rough-in | 3/3/2009 | 3/4/2009 | 3/4/2009 11:15:12 AM | A | PASS |
|
|
This is for a second rough. Please contact Doran with any questions. Phone #: ###-#### Internet Inspection Request from: Diane Houst
|
PLM09-00309
| Plumbing Rough-in | 3/2/2009 | 3/4/2009 | 3/4/2009 10:47:30 AM | A | PASS |
|
|
Ready by 10:00AM Phone #: ###-#### Internet Inspection Request from: John Hensley
|
PLM09-00309
| DOC - Permit Finaled | 3/4/2009 | 3/4/2009 | 3/4/2009 10:47:20 AM | P | PASS |
|
|
Ready by 10:00AM Phone #: ###-#### Internet Inspection Request from: John Hensley
|
PLM09-00313
| Groundwork | 3/3/2009 | 3/4/2009 | 3/3/2009 4:44:11 PM | A | PART |
|
|
ground work pass. need to isolate dishwasher with a rpba, need to isolate ice tea maker with a dbca, need to isolate coffee & espresso with a rpba, need to isolate steamer with a rpba, need to isolate carbonaters with a rpba, need to isolate ice machine with a dbca or have a 1" airgap, need to isolate juicer with a dbca, need to isolate maximixer with a rpba, soap dispenser at mop sink needs it's own water supply & all hosebibs need hosebib vacuum breakers.
|