Inspections for the day of: Friday, March 4, 2016.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Little
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM16-00761 Water and/or Sewer3/4/20163/4/20163/4/2016 4:44:32 PMPFAIL
EXTEND waste piping inside existing auxiliary building,
CHANGE supply piping inside building from 1/2'' to 3/4'',
ADDED tixtures: toilet, floor drain, bathroom sink
CHANGED fixture to barn sink below window
UNDERGROUND and rough-in inspection on test today.Jacqueline Phone #: ###-#### Inspection requested via web by Jacqueline Manderscheid
CRAWL SPACE:
1.hang every 4 feet
2. grade 1/4" per foot
3. use approved glue
4.install 4" c/o
5. test @ 5 psi
AUX BLDG:
1. transition glue not approved in bldg
2. grade 1/4" per foot
3. must be 6" above flood rim before turning horizontal
4. santee not approved ftg on wc vent
5. need full size c/o at upper terminal
6. test @ 5 psi
7. pex joints not approved under slab
8. retest water
PLM16-00763 Plumbing Rough-in3/4/20163/4/20163/4/2016 3:27:12 PMPPASS
Phone #: ###-#### Inspection requested via web by robert goodson
>ri ok
PLM15-04177 Groundwork3/4/20163/4/20163/4/2016 2:44:07 PMPFAIL
Phone #: ###-#### Inspection requested via web by Brent Lacy
>all openings need to be trapped and vented as per city app plans.
>n. side TD was was not inspected.
PLM14-03284 PLM-Aging Inspection3/4/20163/4/20163/4/2016 2:00:10 PM PART
PLM16-00750 Final3/4/20163/4/20163/4/2016 1:59:11 PMPPASS
2ish pm please call Craig ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
>wh and co det ok
PLM16-00722 Final3/2/20163/4/20163/4/2016 1:39:28 PMPPASS
Please call Amy at ###-#### when on way.
Thank You! Phone #: ###-#### Inspection requested via web by Ben Davis
>wh and co det ok
PLM15-04351 Final3/4/20163/4/20163/4/2016 1:13:35 PMPPASS
Jim, we are installing the DW this am. We will send a picture to your phone once completed so you can sign off. Thanks. Scott. Phone #: ###-#### Inspection requested via web by Scott Sparrell
PLM16-00033 Groundwork3/4/20163/4/20163/4/2016 1:13:17 PMPNR
if questions call Chad @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann
>NR but ok'd Chad to stub 10" 90 out fnd wall for storm drain and partially bury, to be under test and inspected monday and must match App plans.
PLM16-00515 Final3/3/20163/4/20163/4/2016 11:46:35 AMAPASS
Re-inspect on final. Call Everett @ ###-#### Inspection requested via web by Sharon Afinson
PLM16-00751 Groundwork3/3/20163/4/20163/4/2016 11:16:51 AMAPASS
if questions call Dustin @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann
>gw ok
PLM15-03425 Water Heater Final3/4/20163/4/20163/4/2016 10:29:00 AMAPASS
###-#### owner
>wh and co detector ok
PLM16-00458 Water and/or Sewer3/3/20163/4/20163/4/2016 10:08:30 AMAPART
Mark Phone #: ###-####
>4" ss to tanks ok from carwash and service
>need to water test tanks
PLM16-00218 Final2/29/20163/4/20163/4/2016 9:40:39 AMAPASS
Please call Stephanie at ###-#### prior to inspection Phone #: ###-#### Inspection requested via web by Mary LaFayette
PLM16-00735 Sprinkler (Final)3/2/20163/4/20163/3/2016 2:25:47 PMAPASS
Cut in sprinkler tee Phone #: ###-#### Inspection requested via web by Rob Bristol
>ok