Inspections for the day of: Monday, March 4, 2019.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-01045 ELE-Aging Inspection3/4/20193/4/20193/5/2019 3:42:56 PM FAIL
Called contact, no answer, left message.
ELE16-00642 Final3/4/20193/4/20193/4/2019 3:47:19 PMPNH
Contact Tom Betty
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Called contact no answer left message.
ELE18-04474 Electrical Rough-In3/1/20193/4/20193/4/2019 3:32:08 PMPPASS
Terry will call from site when ready. Phone #: ###-#### Inspection requested via web by David Baker
Listing and disconnecting means confirmed. Rough in ok
ELE18-04474 Final3/4/20193/4/20193/4/2019 3:31:50 PMPPASS
Terry will call from site when ready. Phone #: ###-#### Inspection requested via web by David Baker Final ok
ELE18-04565 Final3/1/20193/4/20193/4/2019 3:23:38 PMPFAIL
Phone #: ###-#### Inspection requested via web by David Baker
Unable to verify discnnecting means of monument sign, rest ok
ELE18-04565 Electrical Rough-In3/4/20193/4/20193/4/2019 3:22:57 PMPPASS
Phone #: ###-#### Inspection requested via web by David Baker
Listings confirmed on all signs
ELE17-00638 Final3/4/20193/4/20193/4/2019 2:48:35 PMPPASS
Contact Jon Novak
Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Bathroom inspection noted on ELE17-00115. Final ok
ELE19-00335 Final3/4/20193/4/20193/4/2019 2:27:02 PMPFAIL
Phone #: ###-#### Inspection requested via web by Jim Noll
110.14- Unused openings shall be closed. KO seals electrical room, up stairs mezz, up near bar.
210.62- Show window receptacles required on all windows with 12 linear ft or major fraction there of. 3 entrance windows above doors.
300.15- All splices shall be contained in boxes. Dn hall to bathrooms, up near bar.
314.25- All boxes shall have covers, Entry desk, up mech. up near bar.
ELE19-00612 Electrical Rough-In3/4/20193/4/20193/4/2019 1:21:03 PMPPASS
inspect 3 PVC conduits in short trench from back wall to bar island.
There is job parking in back and you can get to construction area through Yen Ching dining Phone #: ###-#### Inspection requested via web by John Edwards
Conduits noted rough in ok cover
MIS19-00059 ELE-Conference3/4/20193/4/20193/4/2019 11:51:00 AMPFAIL
ele work w/o permits
Existing circuit to AC at rear of dwelling.
BCC 4-05-32 No code violationg to be retained. 110.11- Materials installed outdoors shall be rated for outdoors.
110.12- Materials shall not be damaged. NM cable runs exposed on back of dwelling to AC unit has sun exposure damage.
334.12- NM cable shall not be installed in a wet location, shall not be installed in direct sunlight.

25 day notice to have corrected. Dircuit to AC unit shows damage from exposure. Replace with an approved wiring method
ELE19-00565 Final2/25/20193/4/20193/4/2019 11:49:47 AMAFAIL
See also: BLD19-00303
Blue Raven Install Manager: Brian Prussia ###-#### Phone #: ###-#### Inspection requested via web by BRS Permitting
No issues found with solar installation.
BCC 4-05-32 No code violationg to be retained. 110.11- Materials installed outdoors shall be rated for outdoors.
110.12- Materials shall not be damaged. NM cable runs exposed on back of dwelling to AC unit has sun exposure damage.
334.12- NM cable shall not be installed in a wet location, shall not be installed in direct sunlight.

25 day notice to have corrected. Dircuit to AC unit shows damage from exposure. Replace with an approved wiring method.
ELE19-00090 Final3/2/20193/4/20193/4/2019 11:09:37 AMAFAIL
Final was completed, but the permit was reopened so we could add a circuit for smoke detectors.
If there is no one at the house, you can call myself or Jim Thorpe (###-####) for access to get in. Phone #: ###-#### Inspection requested via web by Dan Hilke
210.12- A ll outlets located in bedroom areas shall have AFCI protection. Smoke detectors.
ELE19-00346 Final3/1/20193/4/20193/4/2019 11:06:05 AMAPASS
Contact is Derek Ball Phone #: ###-#### Inspection requested via web by Scott Campbell Small stand alone system to illuminate bus stop shelter. Listing confirmed. Final ok
ELE19-00254 Electrical Rough-In3/1/20193/4/20193/4/2019 10:41:26 AMAPASS
Marcus Phone #: ###-####
Corrections complete. Rough in ok cover
ELE19-00723 Electrical Rough-In3/4/20193/4/20193/4/2019 10:14:47 AMAPASS
Phone #: ###-#### Inspection requested via web by Brad Girard
New entrance rough in ok cover
ELE19-00739 Rough-In Permanent Service3/1/20193/4/20193/4/2019 9:54:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk
Rough in ok cover p/s u/g n ok
ELE19-00633 Rough-In Permanent Service3/4/20193/4/20193/4/2019 9:35:40 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn
Rough in ok cover p/s u/g n ok
ELE19-00008 Final3/1/20193/4/20193/4/2019 9:17:55 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
ELE19-00009 Final3/1/20193/4/20193/4/2019 9:17:28 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok