ELE16-01045
| ELE-Aging Inspection | 3/4/2019 | 3/4/2019 | 3/5/2019 3:42:56 PM | | FAIL |
|
|
Called contact, no answer, left message.
|
ELE16-00642
| Final | 3/4/2019 | 3/4/2019 | 3/4/2019 3:47:19 PM | P | NH |
|
|
Contact Tom Betty Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Called contact no answer left message.
|
ELE18-04474
| Electrical Rough-In | 3/1/2019 | 3/4/2019 | 3/4/2019 3:32:08 PM | P | PASS |
|
|
Terry will call from site when ready. Phone #: ###-#### Inspection requested via web by David Baker Listing and disconnecting means confirmed. Rough in ok
|
ELE18-04474
| Final | 3/4/2019 | 3/4/2019 | 3/4/2019 3:31:50 PM | P | PASS |
|
|
Terry will call from site when ready. Phone #: ###-#### Inspection requested via web by David Baker Final ok
|
ELE18-04565
| Final | 3/1/2019 | 3/4/2019 | 3/4/2019 3:23:38 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by David Baker Unable to verify discnnecting means of monument sign, rest ok
|
ELE18-04565
| Electrical Rough-In | 3/4/2019 | 3/4/2019 | 3/4/2019 3:22:57 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by David Baker Listings confirmed on all signs
|
ELE17-00638
| Final | 3/4/2019 | 3/4/2019 | 3/4/2019 2:48:35 PM | P | PASS |
|
|
Contact Jon Novak Thank you, Phone #: ###-#### Inspection requested via web by Cathy Duchek Bathroom inspection noted on ELE17-00115. Final ok
|
ELE19-00335
| Final | 3/4/2019 | 3/4/2019 | 3/4/2019 2:27:02 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Jim Noll 110.14- Unused openings shall be closed. KO seals electrical room, up stairs mezz, up near bar. 210.62- Show window receptacles required on all windows with 12 linear ft or major fraction there of. 3 entrance windows above doors. 300.15- All splices shall be contained in boxes. Dn hall to bathrooms, up near bar. 314.25- All boxes shall have covers, Entry desk, up mech. up near bar.
|
ELE19-00612
| Electrical Rough-In | 3/4/2019 | 3/4/2019 | 3/4/2019 1:21:03 PM | P | PASS |
|
|
inspect 3 PVC conduits in short trench from back wall to bar island. There is job parking in back and you can get to construction area through Yen Ching dining Phone #: ###-#### Inspection requested via web by John Edwards Conduits noted rough in ok cover
|
MIS19-00059
| ELE-Conference | 3/4/2019 | 3/4/2019 | 3/4/2019 11:51:00 AM | P | FAIL |
|
|
ele work w/o permits Existing circuit to AC at rear of dwelling. BCC 4-05-32 No code violationg to be retained. 110.11- Materials installed outdoors shall be rated for outdoors. 110.12- Materials shall not be damaged. NM cable runs exposed on back of dwelling to AC unit has sun exposure damage. 334.12- NM cable shall not be installed in a wet location, shall not be installed in direct sunlight.
25 day notice to have corrected. Dircuit to AC unit shows damage from exposure. Replace with an approved wiring method
|
ELE19-00565
| Final | 2/25/2019 | 3/4/2019 | 3/4/2019 11:49:47 AM | A | FAIL |
|
|
See also: BLD19-00303 Blue Raven Install Manager: Brian Prussia ###-#### Phone #: ###-#### Inspection requested via web by BRS Permitting No issues found with solar installation. BCC 4-05-32 No code violationg to be retained. 110.11- Materials installed outdoors shall be rated for outdoors. 110.12- Materials shall not be damaged. NM cable runs exposed on back of dwelling to AC unit has sun exposure damage. 334.12- NM cable shall not be installed in a wet location, shall not be installed in direct sunlight.
25 day notice to have corrected. Dircuit to AC unit shows damage from exposure. Replace with an approved wiring method.
|
ELE19-00090
| Final | 3/2/2019 | 3/4/2019 | 3/4/2019 11:09:37 AM | A | FAIL |
|
|
Final was completed, but the permit was reopened so we could add a circuit for smoke detectors. If there is no one at the house, you can call myself or Jim Thorpe (###-####) for access to get in. Phone #: ###-#### Inspection requested via web by Dan Hilke 210.12- A ll outlets located in bedroom areas shall have AFCI protection. Smoke detectors.
|
ELE19-00346
| Final | 3/1/2019 | 3/4/2019 | 3/4/2019 11:06:05 AM | A | PASS |
|
|
Contact is Derek Ball Phone #: ###-#### Inspection requested via web by Scott Campbell Small stand alone system to illuminate bus stop shelter. Listing confirmed. Final ok
|
ELE19-00254
| Electrical Rough-In | 3/1/2019 | 3/4/2019 | 3/4/2019 10:41:26 AM | A | PASS |
|
|
Marcus Phone #: ###-#### Corrections complete. Rough in ok cover
|
ELE19-00723
| Electrical Rough-In | 3/4/2019 | 3/4/2019 | 3/4/2019 10:14:47 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brad Girard New entrance rough in ok cover
|
ELE19-00739
| Rough-In Permanent Service | 3/1/2019 | 3/4/2019 | 3/4/2019 9:54:34 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g n ok
|
ELE19-00633
| Rough-In Permanent Service | 3/4/2019 | 3/4/2019 | 3/4/2019 9:35:40 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
|
ELE19-00008
| Final | 3/1/2019 | 3/4/2019 | 3/4/2019 9:17:55 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
|
ELE19-00009
| Final | 3/1/2019 | 3/4/2019 | 3/4/2019 9:17:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Therrin Robertson Final ok
|