MEC19-00675
| Rough-in | 3/4/2019 | 3/4/2019 | 3/4/2019 3:58:38 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- R/I ok
|
MEC19-00013
| Final | 2/25/2019 | 3/4/2019 | 3/4/2019 3:58:23 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace only co ok
|
MEC19-00605
| Final | 2/28/2019 | 3/4/2019 | 3/4/2019 3:09:10 PM | P | NH |
|
|
Please call Kamille in route to inspection ###-#### --she will be home after 3PM Phone #: ###-#### Inspection requested via web by Justin Osterhout- called number listed non working phone number- went by no adult at home- no access
|
MEC19-00524
| Final | 3/1/2019 | 3/4/2019 | 3/4/2019 2:53:04 PM | P | PASS |
|
|
Call Matt Harrison with questions or concerns @ ###-#### Garage Code is 1234 Phone #: ###-#### Inspection requested via web by Ashley Shoecraft- pellet stove final ok
|
MEC19-00893
| Pressure Test | 3/4/2019 | 3/4/2019 | 3/4/2019 2:41:37 PM | P | PASS |
|
|
somebody should be there.can you call a half hour before heading over?
208--###-#### Phone #: ###-#### Inspection requested via web by Nat Golden- 20lb gas pass whole system- tagged gas line
|
MEC19-00892
| Rough-in | 3/4/2019 | 3/4/2019 | 3/4/2019 2:26:28 PM | P | PASS |
|
|
Call mark 30 min advance to meet inspector jobsite Phone #: ###-#### Inspection requested via web by Manuel Canto- r/i ok- need to seal exhaust fan in laundry where ducting ties onto fan- need ducted toe kicks on 2 lines by final
|
MEC19-00848
| Rough-in | 3/1/2019 | 3/4/2019 | 3/4/2019 2:03:57 PM | P | PASS |
|
|
Fire dampers Phone #: ###-#### Inspection requested via web by RaChelle Frisbee- fire smoke damper framing ok-
|
MEC19-00256
| Rough-in | 2/28/2019 | 3/4/2019 | 3/4/2019 10:55:39 AM | A | PASS |
|
|
Field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney- R/I ok
|
MEC19-00256
| Pressure Test | 2/28/2019 | 3/4/2019 | 3/4/2019 10:55:23 AM | A | PASS |
|
|
Field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney- 20lb gas pass- tagged gas line
|
MEC19-00254
| Rough-in | 2/28/2019 | 3/4/2019 | 3/4/2019 10:54:58 AM | A | PASS |
|
|
Field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney- R/I ok
|
MEC19-00254
| Pressure Test | 2/28/2019 | 3/4/2019 | 3/4/2019 10:54:44 AM | A | PASS |
|
|
Field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney- 20lb gas pass- tagged meter location
|
MEC19-00633
| Rough-in | 3/1/2019 | 3/4/2019 | 3/4/2019 10:07:40 AM | A | PASS |
|
|
Gari ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
|
MEC19-00889
| Rough-in | 3/1/2019 | 3/4/2019 | 3/4/2019 9:49:24 AM | A | PART |
|
|
Rough in - Francisco is your contact Phone #: ###-#### Inspection requested via web by Kim Adams- need to run condensate drain in 3/4" diameter and remove pvc material not plenum rated- front area ok to sheetrock- will look at linear diffusers when installed thru access doors
|
MEC19-00870
| Rough-in | 2/28/2019 | 3/4/2019 | 3/4/2019 9:04:01 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- gas gauge at zero- need approved manual J onsite- need ladder provided by contractor to safely acces furnace in attic- fireplace inner thimble not installed per manufactures installation instructions-fresh air can not come from roof and needs to be tied into R/A plenum off furnace- left correction notice in back window
|
MEC19-00870
| Pressure Test | 3/4/2019 | 3/4/2019 | 3/4/2019 9:01:51 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge at zero psi
|
MEC19-00675
| Rough-in | 3/1/2019 | 3/4/2019 | 3/4/2019 8:40:43 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- man j missing ducting diagram need complete man j onsite- fresh flex duct needs 1" clearance to b vent for water heater in garage attic
|
MEC19-00675
| Pressure Test | 3/1/2019 | 3/4/2019 | 3/4/2019 8:37:38 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass- tagged meter location
|
MEC18-02480
| Mec-Aging Inspection | 3/4/2019 | 3/4/2019 | 3/4/2019 8:14:02 AM | | FAIL |
|
|
need inspection called in by contractor
|
MEC18-02514
| Mec-Aging Inspection | 3/4/2019 | 3/4/2019 | 3/4/2019 8:13:36 AM | | CANC |
|
|
need final inspection called in by contractor when ready- WIP
|
MEC19-00758
| Final | 3/4/2019 | 3/4/2019 | 3/4/2019 8:02:25 AM | A | PASS |
|
|
furnace only co ok
|