Inspections for the day of: Monday, March 4, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-00756 Rough-in3/4/20193/4/20193/4/2019 4:24:11 PMPPART
Phone #: ###-#### Inspection requested via web by Dave Sorensen
- range hood vent only ok
- still need to see the rest of the HVAC rough-in
MEC19-00756 Pressure Test3/4/20193/4/20193/4/2019 4:21:50 PMPFAIL
Phone #: ###-#### Inspection requested via web by Dave Sorensen

-20lb low pressure test needs to be on a 30lb gauge
- 5lb flue pressure test ok
MEC19-00899 Final3/4/20193/4/20193/4/2019 3:40:39 PMPPASS
Please call Tony Hall 1 hour prior to arrival. He starts this install at 11:30a today. Phone #: ###-#### Inspection requested via web by kelly Martin
- furnace and coil only co ok
MEC18-05802 Final3/4/20193/4/20193/4/2019 3:24:03 PMPPASS
final Phone #: ###-#### Inspection requested via web by Brandon Sorensen
- final ok
MEC19-00130 Rough-in3/4/20193/4/20193/4/2019 2:35:13 PMPPART
Phone #: ###-#### Inspection requested via web by Oleg Chervak
- BLD A north side 12 only R/I ok
- contractor is still working on the south 12
MEC19-00263 Final3/4/20193/4/20193/4/2019 2:04:30 PMPCANC
QUESTIONS PLEASE CALL PAUL - ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- should have been a R/I not a final
MEC19-00263 Rough-in3/4/20193/4/20193/4/2019 2:03:55 PMPFAIL
QUESTIONS PLEASE CALL PAUL - ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- furnace doesn't match Man J. and Man J. needs to be approved and stamped onsite
- exhaust fans need to be R/I
MEC18-02487 DOC - Permit Finaled3/4/20193/4/20193/4/2019 1:26:51 PMPPASS
MEC18-02487 Mec-Aging Inspection3/4/20193/4/20193/4/2019 1:25:28 PM PASS
MEC18-02510 Mec-Aging Inspection3/4/20193/4/20193/4/2019 1:16:28 PM DONE
called Access heating and talked with Jackie about this mechanical aging permit
MEC18-02486 Mec-Aging Inspection3/4/20193/4/20193/4/2019 1:11:43 PM DONE
Called Wholesale fireplaces and talked with Bill about this mechanical aging permit.
MEC18-05988 Final3/1/20193/4/20193/4/2019 11:33:54 AMAPASS
Garage code: 5674 or 9378 Phone #: ###-#### Inspection requested via web by Dan Otero
- fireplace final
MEC18-05881 Final3/1/20193/4/20193/4/2019 11:08:35 AMAPASS
And Duct blast witness Phone #: ###-#### Inspection requested via web by Gary Reeves
- duct blast ok
- final ok
MEC18-05816 Final3/1/20193/4/20193/4/2019 11:08:05 AMAPASS
Garage code: 6949 or 2429 Phone #: ###-#### Inspection requested via web by Dan Otero
- fireplace final ok
MEC19-00581 Rough-in3/1/20193/4/20193/4/2019 10:07:56 AMAPART
request for sealer inspection. Please contact job lead Daryl ###-#### with any questions or concerns. Inspection requested via web by Heather Gransbery
- duct seal inspection on clubhouse ok for insulation
MEC19-00885 Pressure Test3/1/20193/4/20193/4/2019 9:28:05 AMAPASS
Late AM inspect please. Call Brack on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- 20lb underground gas pressure test ok
- This gas line is an under ground gas line that was done previously with out a permit. Everything above the ground looks ok. We dont know how deep it is but A-1 has pressure tested it to make sure its ok to add a gas line to the shop for a unit heater. When new gas line has been added schedule another pressure test
MEC18-03905 Final3/1/20193/4/20193/4/2019 9:05:10 AMAFAIL
Inspection requested via web by Marisa Hone
- need to see a working co detector installed
home owner was wanting to have co detector installed where she can access it
- lineset penetration needs sealed
- lineset insulation is missing in crawl in two locations
- lineset needs supported in crawl
- secondary drain on indoor coil needs a wet switch installed
MEC18-05952 Card not on site to sign3/4/20193/4/20193/4/2019 8:36:32 AMPPASS
MEC18-05952 Final3/3/20193/4/20193/4/2019 8:07:01 AMAPASS
CALL MANNY 20 MIN IN ADVANCE Phone #: ###-#### Inspection requested via web by Manuel Canto
- final ok
MEC19-00789 Final3/1/20193/4/20193/1/2019 3:43:26 PMACANC
Please call Lindsay when you are on your way Phone #: ###-#### >> Inspection requested via web by Andrea Grigsby Inspection cancelled from web by: Andrea Grigsby